• Title/Summary/Keyword: laser scan

Search Result 357, Processing Time 0.036 seconds

Localization of Mobile Robot using Local Map and Kalman Filtering (지역 지도와 칼만 필터를 이용한 이동 로봇의 위치 추정)

  • Lim, Byung-Hyun;Kim, Yeong-Min;Hwang, Jong-Sun;Ko, Nak-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1227-1230
    • /
    • 2003
  • In this paper, we propose a pose estimation method using local map acquired from 2d laser range finder information. The proposed method uses extended kalman filter. The state equation is a navigation system equation of Nomad Super Scout II. The measurement equation is a map-based measurement equation using a SICK PLS 101-112 sensor. We describe a map consisting of geometric features such as plane, edge and corner. For pose estimation we scan external environments by laser rage finer. And then these data are fed to kalman filter to estimate robot pose and position. The proposed method enables very fast simultaneous map building and pose estimation.

  • PDF

A Study on Measurement Error Factors of Theodolite System (데오도라이트 시스템의 측정 오차 요인에 대한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.

A Study on the Table Deflection by Stop State and Move Speed at Loaded Load (하중 게재시 정지상태 및 이송속도에 따른 테이블 처짐에 관한 연구)

  • 이지용;김태호;정영덕;박정보;김순경;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1117-1122
    • /
    • 2003
  • The paper on table deflection by stop state and move speed at loaded load, and the table deflection measured of static load. It is developed program for Date correction of LSM(Least Square Method). We experimented the method as following. The first a Laser setting and scan Experimental device measured curvature radius, The second A center of measurement object and curvature radius taking of LSC.

  • PDF

Experimental Modal Analysis by Using Hilbert Transform of Signal from Continuous Scanning Laser Vibrometer (연속 스캐닝 레이저 진동계 신호의 Hilbert 변환을 이용한 실험적 모드 해석)

  • Kang, Min-Sig;Chang, Tae-Gyu;Kim, Ho-Sung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.6
    • /
    • pp.272-277
    • /
    • 2002
  • This paper deals with the vibration deflection shape measurement technique for a sinusoidally excited structure using a continuously scanning laser Doppler vibrometer (CSLV). The CSLV output signal is an amplitude-modulated vibration in which the excitation signal is modulated by the deflection shapes, and thus the deflection shapes of vibration defined along a scan line can be derived by the envelop and the phase information of the CSLV output signal. In this work, a Hilbert transform based approach has been proposed for measurement of deflection shapes. This technique is as simple as the demodulation technique and allows more convenient experimental settings than the Fourier transform approach. The feasibility of the proposed technique is illustrated along with results of experiment.

Organizing Lidar Data Based on Octree Structure

  • Wang, Miao;Tseng, Yi-Hsing
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.150-152
    • /
    • 2003
  • Laser scanned lidar data record 3D surface information in detail. Exploring valuable spatial information from lidar data is a prerequisite task for its applications, such as DEM generation and 3D building model reconstruction. However, the inherent spatial information is implicit in the abundant, densely and randomly distributed point cloud. This paper proposes a novel method to organize point cloud data, so that further analysis or feature extraction can proceed based on a well organized data model. The principle of the proposed algorithm is to segment point cloud into 3D planes. A split and merge segmentation based on the octree structure is developed for the implementation. Some practical airborne and ground lidar data are tested for demonstration and discussion. We expect this data organization could provide a stepping stone for extracting spatial information from lidar data.

  • PDF

A Study on the Form Accuracy Improvement of Mold Core for F-Theta Lens (F-Theta Lens 금형코어 형상정도 향상에 관한 연구)

  • Kim S.S.;Jeong S.H.;Kim H.U.;Kim H.J.;Kim J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.777-780
    • /
    • 2005
  • The global consumption of aspheric surfaces will expand rapidly on the Electronics and Optical Components Information and Communications, Aerospace and Defense, and Medical optics markets etc. We must research on market, technology forecast and analysis of aspheric surfaces that is a principle step of ultra precision machine technology with a base one of optical elements. Especially, F-theta lens is one of the important parts in LSU(Laser scanning unit) because it affects on the optical performance of LSU dominantly. The core is most of important to produce plastic F-theta lens by plastic injection molding method, which is necessary to get the ultra-precision aspheric and non-axisymmetric machine processing technology.

  • PDF

Effects of therapeutic ultrasound for contour asymmetry after liposuction, a case study

  • Wong, Yiu Ming
    • CELLMED
    • /
    • v.5 no.3
    • /
    • pp.19.1-19.2
    • /
    • 2015
  • This is a case report involving a novel setting of sonographic scan for thickness of superficial abdominal fat and a non-invasive approach for reduction of the fat thickness. A 38-year-old woman complained of her abdominal contour asymmetry after the laser-assisted liposuction performed two years ago. Compression-free sonographic scanning confirmed that her superficial abdominal fat was thicker in left side than that of right side. After 9 sessions of 40KHz therapeutic ultrasound, the contour asymmetry was reduced.

Development of Highly Accurate Inspection System for Cylindrical Aluminum Casts with Microscopic Defects

  • Shinji, Ohyama;Hong, Keum-Shik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.35.3-35
    • /
    • 2001
  • Developed is an optical auto-inspection system to detect some microscopic defects on the Inside surface of the hydraulic automobile brakes at the production line. A small cylindrical detection module with a solid laser source at its center has two rings of optical fibers to separately collect light reflected and scattered from the defects on the surface. The cylindrical brake part rotates with respect to the detection module that will move parallel to the rotational axis of the cylinder. Thus, the optical module can scan the whole inside surface area. The automatic detection of the defects is to compare the intensity distributions ...

  • PDF

Development of a Laser-Generated Ultrasonic Inspection System by Using Adaptive Error Correction and Dynamic Stabilizer (적응적 에러 보정과 다이나믹 안정기를 이용한 레이저 유도 초음파 검사 시스템 개발)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Park, Moon-Cheol;Lim, Chang-Hwan;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.391-399
    • /
    • 2005
  • Laser-generated ultrasonic inspection system is a non-contact scanning inspection device with high spatial resolution and wide bandwidth. The amplitude of laser-generated ultrasound is varied according to the energy of pulse laser and the surface conditions of an object where the CW measuring laser beam is pointing. In this paper, we correct the generating errors by measuring the energy of pulse laser beam and correct the measuring errors by extracting the gain information of laser interferometer at each time. h dynamic stabilizer is developed to stably scan on the surface of an object for an laser-generated ultrasonic inspection system. The developed system generates ultrasound after adaptively finding the maximum gain time of an laser interferometer and processes the signal in real time after digitization with high speed. In this paper, we describe hardware configuration and control algorithm to build a stable laser-generated ultrasonic inspection system. Also, we confirmed through experiments that the proposed correction method for the generating errors and measuring errors is effective to improve the performance of a system.

An Accuracy Analysis of the 3D Automatic Body Measuring Machine (3차원 자동체형계측기 정밀도 검사)

  • Jeon, Soo-Hyung;Kwon, Suk-Dong;Park, Se-Jung;Kim, Jung-Yang;Song, Jung-Hoon;Kim, Hyun-Jin;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF