• 제목/요약/키워드: laser scan

검색결과 357건 처리시간 0.029초

레이저 주사 장치의 곡률 보정에 관한 연구 (A Study on the Curvature Correction in Laser Scanner)

  • 윤남일;김남;박한규
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1986년도 추계학술발표회 논문집
    • /
    • pp.194-197
    • /
    • 1986
  • In this paper, for the curvature correction on the scanning plane in laser scanning system, aberration correction method using holographic optical element is suggested. Holoens is selected as a type of holographic zone plate which has aberration correction property. And hologram recording condition is analyzed to find fo property. This hololens is implemented by computer-generated hologram technique. Laser scanning system is organized using desinged hololens and scanning properties of this system are investigated. Using this method optical system structure in laser scanning system can be simplified satisfying both scan linearity and field flatness.

  • PDF

블록 보간법을 이용한 산업용 로봇의 3차원 위치 보정기법 (A 3-D Position Compensation Method of Industrial Robot Using Block Interpolation)

  • 류항기;우경행;최원호;이재국
    • 제어로봇시스템학회논문지
    • /
    • 제13권3호
    • /
    • pp.235-241
    • /
    • 2007
  • This paper proposes a self-calibration method of robots those are used in industrial assembly lines. The proposed method is a position compensation using laser sensor and vision camera. Because the laser sensor is cross type laser sensor which can scan a horizontal and vertical line, it is efficient way to detect a feature of vehicle and winding shape of vehicle's body. For position compensation of 3-Dimensional axis, we applied block interpolation method. For selecting feature point, pattern matching method is used and 3-D position is selected by Euclidean distance mapping between 462 feature values and evaluated feature point. In order to evaluate the proposed algorithm, experiments are performed in real industrial vehicle assembly line. In results, robot's working point can be displayed 3-D points. These points are used to diagnosis error of position and reselecting working point.

마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정 (Temperature measurement of the spray flame using micro scale absorption bands and line strength)

  • 최경민
    • 한국분무공학회지
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

스텝모터를 활용한 정밀 스케닝 구현에 관한 고찰 (Implementation of the laser scanning using the step motor)

  • 전삼석;박찬원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.967-968
    • /
    • 2007
  • This report is the study for laser scanning. Scanning control of $CO_2$ laser, He-Ne laser, used for the treatment of body skin, has relatively low band about hundered Hz. It could be used as a substitiute for expensive galvanometer that is the established scan method, which operates the number of KHz movement by using step motor when it operates low speed. To increase the accuracy of step motor's the angle of rotation, We could materialize 100Hz low band by using open loop, closed loop method with microprocessor. This causes it to be stable even direction by attaching electric capacity sensor. Therefore, We could expect to reduce the cost by manufacturing low band scanner rather than costly feedback galvanometer.

  • PDF

토끼의 관절병증에 미치는 SCAN-BIO 레이저의 치료효과 (Effect of scan-bio laser therapy on arthropathy in rabbits)

  • 조형진;김영수;오동민;심경미;강성수;임성철;조용성;이수한;최석화;배춘식
    • 대한수의학회지
    • /
    • 제44권3호
    • /
    • pp.475-482
    • /
    • 2004
  • For the induction of arthropathy, 4% hydrogen peroxide ($H_2O_2$) was injected for 4 weeks into the intra-articular space of the 25 New Zealand white rabbits to damage articular cartilage. The verification of arthropathy induction and the effect of scan-bio laser treatment were determined by measuring superoxide dismutase (SOD) activity, by observing gross and histopathologic findings. The SOD activity increased by about 40% in arthropathy group, as compared to controls. Although SOD activity in arthropathy group was not significantly different from the 2-week group, it was significantly different from the 4-week control and treatment groups. There was also a significant difference between the 4-week control and treatment groups. Grossly, erosions formed on the articular cartilage surface, and the lateral femoral condyle was damaged in arthropathy group. In comparison, there was slight, but not significant, progression of the lesion in the 2-week control group, and no difference between the 2-week treatment and control groups. Conversely, severe erosions damaged the articular cartilage in the 4-week control group. Cartilage proliferation was seen in gross observations in the 4-week treatment group, suggesting a treatment effect. Histopathologically, there was slight articular surface damage and apoptosis in arthropathy group, and serious cartilage damage, despite slight chondrocyte proliferation, in the 4-week control group. By contrast, the 4-week treatment group showed chondrocyte replacement, with close to normal articular cartilage on the articular surface. There was significant cartilage proliferation with regeneration of the articular cartilage on the articular surface in the group treated with low-level laser, as compared to control group, when arthropathy was induced by $H_2O_2$ injections. Therefore, low-level laser was effective in the treatment of chemically induced arthropathy.

마찰 보상과 지도 정합에 의한 미끄럼 조향 이동로봇의 실내 주행 (Indoor Navigation of a Skid Steering Mobile Robot Via Friction Compensation and Map Matching)

  • 소창주;유준
    • 제어로봇시스템학회논문지
    • /
    • 제19권5호
    • /
    • pp.468-472
    • /
    • 2013
  • This paper deals with the indoor localization problem for a SSMR (Skid Steering Mobile Robot) subjected to wheel-ground friction and with one LRF (Laser Range Finder). In order to compensate for some friction effect, a friction related coefficient is estimated by the recursive least square algorithm and appended to the maneuvering command. Also to reduce odometric information based localization errors, the lines are extracted with scan points of LRF and matched with the ones of the corresponding map built in advance. The present friction compensation and scan map matching schemes have been applied to a laboratory SSMR, and experimental results are given to validate the localization performance along an indoor corridor.

Raman Chemical Imaging Technology for Food and Agricultural Applications

  • Qin, Jianwei;Kim, Moon S.;Chao, Kuanglin;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.170-189
    • /
    • 2017
  • Purpose: This paper presents Raman chemical imaging technology for inspecting food and agricultural products. Methods The paper puts emphasis on introducing and demonstrating Raman imaging techniques for practical uses in food analysis. Results & Conclusions: The main topics include Raman scattering principles, Raman spectroscopy measurement techniques (e.g., backscattering Raman spectroscopy, transmission Raman spectroscopy, and spatially offset Raman spectroscopy), Raman image acquisition methods (i.e., point-scan, line-scan, and area-scan methods), Raman imaging instruments (e.g., excitation sources, wavelength separation devices, detectors, imaging systems, and calibration methods), and Raman image processing and analysis techniques (e.g., fluorescence correction, mixture analysis, target identification, spatial mapping, and quantitative analysis). Raman chemical imaging applications for food safety and quality evaluation are also reviewed.

광조형법에 있어서 OFFSET정보생성 알고리즘 개발에 관한 연구 (A Study on Algorithm Development of Offset Data Generation in Stereolithography)

  • 김준안;홍삼열;백인환
    • 한국정밀공학회지
    • /
    • 제13권9호
    • /
    • pp.70-76
    • /
    • 1996
  • In the Stereolithography process, three-dimensional objects are built by sequentially curing, generated by horizontal slicing of a three-dimensional CAD model. The dimensional accuracy of a menufactured part depends on the accuracy of curing performed by laser beam radius and the half of curing width. When offsetting, some slices have collinear segments, coincident vertices, line jerks and open loops. After remove above issues we have correct offsets data. And in last step, these data are used to scan paths.

  • PDF

집속 레이저 빔에 의한 PDP 격벽의 마스크레스 식각 (Maskless etching of the PDP barrier rib using focused laser beam)

  • 안민영;이경철;이홍규;최훈영;이천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1849-1851
    • /
    • 1999
  • The PDP(Plasma Display Panel) barrier rib was fabricated by focused $Ar^+$ laser ($\lambda$=514nm) and Nd:YAG($\lambda$=532, 266 nm) laser irradiation. The depth of the etched groove increases with increasing a laser fluence. and decreasing a scan speed. Using the second harmonic of the Nd:YAG laser, the threshold laser fluence was $6.5mJ/cm^2$ for the sample of PDP barrier rib dried at $120^{\circ}C$. The thickness of $150{\mu}m$ of the sample on the glass was etched without any damage on the glass substrate by fluence of $19.5J/cm^2$. The barrier rib sample on hot plate was etched by Nd:YAG laser(532 nm) as increasing a temperature of the sample. In this case, the etch rate was $95{\mu}m/s$, $190{\mu}m/s$ at room temperature, $175^{\circ}C$ respectively.

  • PDF

시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가 (The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration)

  • 이대희;위광재;김승용;김갑진;이재원
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF