• Title/Summary/Keyword: laser intensity

Search Result 787, Processing Time 0.023 seconds

Development of Laser-driven Proton Source Toward Its Applications

  • Sagisaka, Akito;Daido, Hiroyuki;Pirozhkov, Alexander S.;Yogo, Akifumi;Ogura, Koichi;Orimo, Satoshi;Ma, Jinglong;Mori, Michiaki;Nishiuchi, Mamiko;Bulanov, Sergei V.;Esirkepov, Timur Zh.;Oishi, Yuji;Nayuki, Takuya;Fujii, Takashi;Nemoto, Koshichi;Nagatomo, Hideo
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.37-41
    • /
    • 2009
  • We observe the proton signals produced by laser interaction with thin-foil targets of polyimide and of copper. We change the thickness of the polyimide target to $7.5{\mu}m$, $12.5{\mu}m$, and $50{\mu}m$. High-energy protons with the maximum energy of ${\sim}2.3\;MeV$ from $7.5{\mu}m$ thick polyimide are observed. This proton beam with the maximum energy of multi-MeV has various applications such as a proton shadowgraphy.

Analysis of Heavy Metal Concentration in Construction By-Products using Laser-Induced Breakdown Spectroscopy and Membrane Techniques (레이져 유도 플라즈마 분광법(LIBS)과 멤브레인을 활용한 건설용 부산물 내 중금속 분석에 관한 연구)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.113-121
    • /
    • 2023
  • In this study, the applicability and reproducibility of laser induced breakdown spectroscopy(LIBS) for heavy metal analysis in clinker and 5 types of by-products(crushed stone sludge, blast furnace slag, steel slag, waste concrete sludge, bottom ash) were experimentally reviewed. As a result of ICP-MS, XRF, and LIBS analysis of the six samples, the difference between ICP and XRF was confirmed in the quantitative analysis, but the LIBS analysis showed a difference by element from the standard analysis, and only qualitative analysis of the sample was possible. LIBS analysis wavelength was set for three types of heavy metals(Cd - 214.44nm, Pb - 405.78nm, Hg - 253.65nm). As a result of laser irradiation on the surface of the membrane impregnated with a solution of each concentration(1~1000ppm) and dried, the correlation between the spectral intensity and the concentration was confirmed.

Investigation of the optimum condition for the quantitative analysis of Cu sample by Laser induced breakdown spectroscopy (구리 시료의 정량분석을 위한 LIBS의 최적조건 연구)

  • Kim, Seunghyun;Shin, Heesung;Ju, Junesik;Kim, Hodong
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • A laser induced breakdown spectroscopy (LIBS) measurement was carried out to derive an optimized measurement condition with a high reproducibility and to grow a plasma sphere to 20 mm high under a 600 mtorr vacuum in order to improve an accuracy of measurement. The measurement of the plasma was taken at a 6.0 mm distance, in the direction of a plasma sphere, from a sample. This location belongs to the outer sphere region in the plasma. The calibration curve of 'Ni' and 'Cu' was acquired by the signal intensity ratio and the atomic ratio for the samples, and linear regression of 'Cu' was $R^2$=0.9886, and the linear regression of 'Ni' was $R^2$=0.9988. The accuracy of LIBS was improved pre-existence as the measurement error of 'Ni' was 0.78%.

A Study for Stray Light Distribution of Mobile Phone Camera Consisting of Two Aspheric Lenses (2매 비구면 렌즈로 구성된 폰 카메라에서 미광 분포에 대한 연구)

  • Park, Kwang-Woo;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.6-15
    • /
    • 2009
  • A mobile phone camera consisting of two aspheric lenses is designed, and stray light distribution on the image plane is analyzed. We assume that most of the incident light is absorbed on the inner surfaces of the lens barrel and spacers, only a small fraction of the light is scattered uniformly. Assuming that 10% of the incident light is scattered on the barrel and spacers, the maximum value of stray light is 7.1% of the ideal image intensity. The result of analysis shows that stray light originated mostly from internal reflection on the ribs. The contributions of scattering by the barrel and spacers are relatively small. To reduce the internal reflection, thin absorbing plates are inserted between lenses, and the shapes of spacers are modified. After the redesigning of the lens barrel, the maximum value of stray light is reduced to 1.1% of the ideal image intensity.

Smoke Detection Based on RGB-Depth Camera in Interior (RGB-Depth 카메라 기반의 실내 연기검출)

  • Park, Jang-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • In this paper, an algorithm using RGB-depth camera is proposed to detect smoke in interrior. RGB-depth camera, the Kinect provides RGB color image and depth information. The Kinect sensor consists of an infra-red laser emitter, infra-red camera and an RGB camera. A specific pattern of speckles radiated from the laser source is projected onto the scene. This pattern is captured by the infra-red camera and is analyzed to get depth information. The distance of each speckle of the specific pattern is measured and the depth of object is estimated. As the depth of object is highly changed, the depth of object plain can not be determined by the Kinect. The depth of smoke can not be determined too because the density of smoke is changed with constant frequency and intensity of infra-red image is varied between each pixels. In this paper, a smoke detection algorithm using characteristics of the Kinect is proposed. The region that the depth information is not determined sets the candidate region of smoke. If the intensity of the candidate region of color image is larger than a threshold, the region is confirmed as smoke region. As results of simulations, it is shown that the proposed method is effective to detect smoke in interior.

Measuring System for Impact Point of Arrow using Mamdani Fuzzy Inference System (Mamdani 퍼지추론을 이용한 화살의 탄착점 측정 시스템)

  • Yu, Jung-Won;Lee, Han-Soo;Jeong, Yeong-Sang;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.521-526
    • /
    • 2012
  • The performance of arrow from a manufacturing process depends on arrow's trajectory(archer's paradox) and intensity of an impact points. Especially, when conducting a shooting experiment over and over in the same experiment condition, the intensity of impact point is an objective standard to judge the performance of the arrow. However, the analysis method for the impact point is not enough, a previous research of the arrow's performance has been focused on a skill to optimize a manufacturing variables(feathers of an arrow, barb of an arrow, arrow's shaft, weight, external diameter, spine). In this paper, We propose measurement system of arrow's impact point with Mamdani fuzzy inference system and similarity of polygon for automation of impact point's measurement. Measuring the impact point data of the arrow moving with a high speed(approximately 275km/h) by using line laser and photo diode array, then the measured data are mapped to arrow's impact point with fuzzy inference and similarity of polygon.

The Effects of Low-Intensity Ultrasound and Laser on Healing of Bone Fracture (저강도 레이저와 초음파의 동시 적용이 골절 치유 촉진에 미치는 효과)

  • Lee, Hyun-Kee
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.331-372
    • /
    • 2003
  • The purpose of study was to evaluate effects of low-intensity ultrasound and laser on healing of bone fracture. Twenty fracture patient were selected for this study(fourteen males, six females. mean aged 44.8) fracture area was humerus, tibia, forearm bones. The obtain result are as follows. 1. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in male(P<.001). 2. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in female(P<.001). 1. The result of this study were following that pain score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 4. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in male between age(P<.001). 5. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in female between age (P<.001). 6. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in male(P<.001). 7. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in female(P<.001). 8. The result of this study were following that radiologic score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 9. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in male between ages(P<.001). 10. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in female between ages(P<.001). 11. The result of this study were following that healing on fracture area was observed that reduced pre intervention compared with post intervention

  • PDF

Photodynamic Inactivation of Moraxella catarrhalis (Moraxella catarrhalis의 광역학적 비활성화)

  • Hong, Seong-No;Kwon, Pil-Seung;Kim, Dae-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.19-24
    • /
    • 2007
  • The aim of this study was to evaluate the bacterial effects of Moraxella catarrhalis in otitis media with effusion (OME) by photodynamic therapy (PDT). Bacterial suspensions (10000 CFU/mL) were prepared. The colony forming units (CFU) of Moraxella catarrhalis have been measured after an application of photogem plus 632 nm diode laser irradiation. One ml of the bacterial suspensions have been incubated in the dark for 3h with various concentrations of photogem ($0.625{\sim}5.0_{\mu}g/mL$) and then irradiated with 632 nm diode laser ($15J/cm^2$). After, the PDT Moraxella catarrhalis suspensions ($50{\mu}L$) were inoculated on chocolate agar plate and cultured in the dark at $37^{\circ}C$, 5% $CO_2$ condition for 18h. The colony forming units off the bacteria were measured. Also transmission electron microscopy (TEM) was employed to evaluate the effect of otitis media pathogens by PDT. The nucleus of Moraxella catarrhalis was stained using green fluorescent nucleic acid dye thiazole orange and the fluorescence intensity of the nucleus was measured by flow cytometry. The PDT was effective in killing Moraxella catarrhalis at the photogem dose of $5.0_{\mu}g/mL$, respectively, As assessed by flow cytometry analysis the fluorescence intensity of the nucleus got lower after PDT. TEM result appeared to able to cause damage to the bacterial membranes. On the basis of these findings, bacterial photodynamic therapy with photogem can be considered to be a promising new therapeutic approach for OME.

  • PDF

Observation of Methyl Radical Recombination Following Photodissociation of CH3I at 266 nm by Time-Resolved Photothermal Spectroscopy

  • Suh, Myung-Koo;Sung, Woo-Kyung;Li, Guo-Sheng;Heo, Seong-Ung;Hwang, Hyun-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.318-324
    • /
    • 2003
  • A time-resolved probe beam deflection (PBD) technique was employed to study the energy relaxation dynamics of photofragments produced by photodissociation of $CH_3I$ at 266 nm. Under 500 torr argon environment, experimental PBD transients revealed two energy relaxation processes; a fast relaxation process occurring within an acoustic transit time (less than 0.2 ㎲ in this study) and a slow relaxation process with the relaxation time in several tens of ㎲. The fast energy relaxation of which signal intensity depended linearly on the excitation laser power was assigned to translational-to-translational energy transfer from the photofragments to the medium. As for the slow process, the signal intensity depended on square of the excitation laser power, and the relaxation time decreased as the photofragment concentration increased. Based on experimental findings and reaction rate constants reported previously, the slow process was assigned to methyl radical recombination reaction. In order to determine the rate constant for methyl radical recombination reaction, a theoretical equation of the PBD transient for a radical recombination reaction was derived and used to fit the experimental results. By comparing the experimental PBD curves with the calculated ones, the rate constant for methyl recombination is determined to be $3.3({\pm}1.0)\;{\times}\;10^6\;s^{-1}torr^{-1}$ at 295 ± 2 K in 500 torr Ar.

Photoluminescence of ZnGa2O4-xMx:Mn2+ (M=S, Se) Thin Films

  • Yi, Soung-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.6
    • /
    • pp.13-16
    • /
    • 2003
  • Mn-doped $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) thin film phosphors have been grown using a pulsed laser deposition technique under various growth conditions. The structural characterization carr~ed out on a series of $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) films grown on MgO(l00) substrates usmg Zn-rich ceramic targets. Oxygen pressure was varied from 50 to 200 mTorr and Zn/Ga ratio was the function of oxygen pressure. XRD patterns showed that the lattice constants of the $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) thin film decrease with the substitution of sulfur and selenium for the oxygen in the $ZnGa_2O_4$. Measurements of photoluminescence (PL) properties of $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) thin films have indicated that MgO(100) is one of the most promised substrates for the growth of high quality $ZnGa_2O_{4-x}M_{x}$:$Mn^{2+}$ (M=S, Se) thin films. In particular, the incorporation of Sulfur or Selenium into $ZnGa_2O_4$ lattice could induce a remarkable increase in the intensity of PL. The increasing of green emission intensity was observed with $ZnGa_2O_{3.925}Se_{0.075}:$Mn^{2+}$ and $ZnGa_2O_{3.925}S_{0.05}$:$Mn^{2+}$ films, whose brightness was increased by a factor of 3.1 and 1.4 in comparison with that of $ZnGa_{2}O_{4}$:$Mn^{2+}$ films, respectively. These phosphors may promise for application to the flat panel displays.