• Title/Summary/Keyword: laser intensity

Search Result 787, Processing Time 0.033 seconds

Evaluation of Kinetic Energy of Raindrops at Daejeon city using Laser-optical Disdrometer (레이저-옵티컬 디스드로미터를 활용한 대전지역의 강우에너지 특성 평가)

  • LIM, Young Shin;KIM, Jong Wook;KIM, Jin Kwan;PARK, Byong Ik
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.2
    • /
    • pp.133-143
    • /
    • 2012
  • To evaluate the kinetic energy of the raindrops, the drop size distribution and the terminal velocity of the raindrops had been measured from January to September 2010 using the laser-optical disdrometer in KIGAM, Daejeon, Korea. The relationship between kinetic energy (KE) and rainfall intensity (I) was computed as logarithmic and exponential model, respectively, under the rainfall intensity of about 142mm/h. The exponential model is more suitable for the relationship of KE-I than the logarithmic model, because the exponential model presented better fit for KE over 50mm/h of rainfall intensity. Meanwhile, the differences of the total kinetic energy existed in rainfall events with almost same total rainfall depth, and KE values of Daejeon at high rainfall intensity underestimated rather than the others under temperate climate. Therefore, these differences of KE in rainfall events and geographical regions imply the result from the variations of rainfall intensity within a rainfall event.

Intravenous Remifentanil Infusion during EVLT for Varicose Vein (하지 정맥류에 대한 정맥내 레이저 치료시 레미펜타닐의 사용)

  • Hwang, Seong-Wook;Sohn, Dong-Suep;Cho, Dai-Yun
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.247-252
    • /
    • 2008
  • Background: We compared the analgesic effects of an intravenous infusion of remifentanil with local lidocaine injection during endovenous laser treatments (EVLT) for varicose veins. Material and Method: In order to compare the efficacy of analgesia between the lidocaine group (n=15) and the remifentanil group (n=15), we measure the pain intensity of the patients, with using the visual analogue scale, during EVLT and at the first week, the second week, the third week and the fourth week after EVLT. Result: The remifentanil group showed significantly less pain intensity during EVLT (p<0.01), but there were no differences of pain intensity between the two groups from the first week to the fourth week after EVLT (p>0.3). Conclusion: The result showed that the intravenous infusion of remifentanil during EVLT can be a good option to reduce pain during EVLT for treating varicose veins.

A feasibility study on photo-production of 99mTc with the nuclear resonance fluorescence

  • Ju, Kwangho;Lee, Jiyoung;ur Rehman, Haseeb;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.176-189
    • /
    • 2019
  • This paper presents a feasibility study for producing the medical isotope $^{99m}Tc$ using the hazardous and currently wasted radioisotope $^{99}Tc$. This can be achieved with the nuclear resonance fluorescence (NRF) phenomenon, which has recently been made applicable due to high-intensity laser Compton scattering (LCS) photons. In this work, 21 NRF energy states of $^{99}Tc$ have been identified as potential contributors to the photo-production of $^{99m}Tc$ and their NRF cross-sections are evaluated by using the single particle estimate model and the ENSDF data library. The evaluated cross sections are scaled using known measurement data for improved accuracy. The maximum LCS photon energy is adjusted in a way to cover all the significant excited states that may contribute to $^{99m}Tc$ generation. An energy recovery LINAC system is considered as the LCS photon source and the LCS gamma spectrum is optimized by adjusting the electron energy to maximize $^{99m}Tc$ photo-production. The NRF reaction rate for $^{99m}Tc$ is first optimized without considering the photon attenuations such as photo-atomic interactions and self-shielding due to the NRF resonance itself. The change in energy spectrum and intensity due to the photo-atomic reactions has been quantified using the MCNP6 code and then the NRF self-shielding effect was considered to obtain the spectrums that include all the attenuation factors. Simulations show that when a $^{99}Tc$ target is irradiated at an intensity of the order $10^{17}{\gamma}/s$ for 30 h, 2.01 Ci of $^{99m}Tc$ can be produced.

The Properties of Diffraction Efficiency in Polarization Holography using the Ag and MgF2/AsGeSeS Multi-layer (Ag 및 MgF2/AsGeSeS 다층박막에서의 편광 홀로그래피 회절효율 특성)

  • 나선웅;여철호;정홍배;김종빈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1070-1074
    • /
    • 2002
  • We have carried out two-beam interference experiments to form holographic gratings on As$_{40}$ Se$_{15}$ S$_{35}$Ge$_{10}$ single layer, Ag/As$_{40}$ Se$_{15}$ S$_{35}$Ge$_{10}$ multi-layer. In this study, holographic gratings have been formed using He-Ne laser(632.8nm) under different polarization combinations(intensity polarization holography, phase polarization holography). The diffraction efficiency was obtained by the +lst order intensity. The maximum diffraction efficiency of As$_{40}$ Se$_{15}$ S$_{35}$Ge$_{10}$ single layer, As$_{40}$ Se$_{15}$ S$_{35}$Ge$_{10}$ and MgF$_2$/As$_{40}$ Se$_{15}$ S$_{35}$Ge$_{10}$ multi-layer were 0.8%, 1.4% and 3.1% under intensity polarization holography, respectively.

Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy (레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.137-146
    • /
    • 2004
  • Laser Induced Breakdown Spectroscopy(LIBS) system is being developed as an in-situ analysis system for the radioactive waste glass in the cold crucible melter. In order to complete the LIBS system, a spectrometer, a detector, and a laser were structured. An ESA 3000 (LLA Instruments GmbH, Germany) including a calibrated Kodak KAF-1001 CCD detector was selected as the spectrometer. A Q-switched Nd-YAG Brilliant(Quantel, France) laser was selected as an energy source. As the first research stage, the excitation temperatures of Fe(I) as a function of the detector's delay intervals(500, 1000, 1500, 2000ns) were evaluated using the Einstein-Boltzmann equation. The optimized excitation temperature of Fe (I) was 7820k at the delay time of 1500㎱ using the 532nm Nd-YAG laser pulse. This LIBS system will be optimized under the real environment vitrification facility in the near future and then used to be in-situ analyzed the glass compositions in the melter qualitatively.

  • PDF

Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: A randomized clinical trial

  • Qamruddin, Irfan;Alam, Mohammad Khursheed;Abdullah, Habiba;Kamran, Muhammad Abdullah;Jawaid, Nausheen;Mahroof, Verda
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • Objective: The aim of this study was to assess the analgesic effect of a single application of low-level laser therapy (LLLT) on spontaneous pain and pain on chewing after placement of initial archwires. Methods: Forty-two patients (26 women, 16 men) were randomly recruited for this split-mouth randomized clinical trial. Each patient received super-elastic nickel-titanium (NiTi) initial archwires (0.012, 0.014, 0.016, and 0.018-inch [in]) in the maxilla for leveling and alignment for an interval of 4 weeks between archwires. One side of the mouth was randomly designated as experimental, while the other side served as placebo. After insertion of each archwire, the experimental side was irradiated with a diode laser for 3 seconds each on 5 points facially and palatally per tooth, from the central incisor to first molar. On the placebo side, the laser device was held the same way but without laser application. A numerical rating scale was used to assess the intensity of spontaneous and masticatory pain for the following 7 days. The Mann-Whitney U test was used to compare pain scores between sides. Results: Patients in the LLLT group exhibited significantly lower mean scores for spontaneous pain after insertion of the initial two archwires (0.012-in and 0.014-in NiTi; p < 0.05), while there was no significant difference for 0.016-in and 0.018-in wires between the LLLT and placebo groups. LLLT significantly reduced chewing pain scores (p < 0.05) for all archwires. Conclusions: A single dose of LLLT considerably lessened postoperative pain accompanying the placement of super-elastic NiTi wires for initial alignment and leveling.

An immunohistochemical study on the effects of low-level laser irradiation on expression of actin filaments of human gingival fibroblasts in vitro (저출력레이저조사가 배양치은섬유아 세포의 actin filaments발현에 미치는 영향에 관한 면역조직화학적 연구)

  • Kim, Hyung-Sung;Kim, Chun-Suk;Kim, Hyung-Soo;Kim, Hyun-Seop;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.1003-1012
    • /
    • 1996
  • The induction of a phenotype with preoperties may have clinical significance in the acceleration of the wound-healing process. Wound contraction involves a specialized cell known as the myofibroblast. The myofibroblasts can be identified by their intense staining of actin bundles with anti-actin antibody. Tissue-specific actin distribution is correlated with the contractile activity of the myofibroblasts and smooth muscle etc. This study was performed to determine the expression of actin filaments in the cytoplasm of cultured human gingival fibroblsts after GaAs laser(BIOSAER, Korea) irradiation. Human gingival fibroblasts were cultured from explants of normal interdental gingival tissue. The third-generation fibroblasts were used for immunohistochemical study. The cultured fibroblasts were exposed $0.53joule/cm^2$(lmW, 7 mimutes) of energy density, and then observed by immunohistochemical method using, rabbit anti0gelsolin, hen smooth muscle polyclonal antibody(Chemicon international inc.), and biotinylated goat anti-rabbit IgG(Vectastain) 24-, 36-, 48-hour after laser irradiation Following results were obtained ; 1. In nonirradiated cultures, round shaped active fibroblasts with abundant cytoplasm and prominet nucleoli were observed. 2. In 24- and 36-hour cultures after laser irradiation, spindle shaped cells with long process were observed. The intensity of stain was seen in cytoplasm of these modified fibroblasts. 3. In 48-hoour cultures after laser irradiation, stained spindle shape cell were not observed. The results suggest that the effect of the galium-arsenide laser treatment on cultured gingival fibroblasts is the rapid development of cytoplasmic actin filaments.

  • PDF

Low-Level Laser Therapy including Laser Acupuncture for Non-Specific Chronic Low Back Pain: Systematic Review and Meta-Analysis

  • Yeum, Hyewon;Hong, Yejin;Nam, Dongwoo
    • Journal of Acupuncture Research
    • /
    • v.38 no.1
    • /
    • pp.8-19
    • /
    • 2021
  • Low-level laser therapy including laser acupuncture (LLLT/LA) has been widely used for non-specific chronic low back pain (NCLBP). However, there is no critically appraised evidence of its potential benefits. This study aimed to evaluate the effectiveness of LLLT/LA for NCLBP. There were 12 databases (MEDLINE, CENTRAL, EMBASE, KoreaMed, KMBASE, KISS, NDSL, KISTI, OASIS, CNKI, CiNII, J-stage) searched for randomized controlled trials using LLLT/LA for NCLBP up until June 2019. The primary outcome was pain intensity and functional status/disability due to NCLBP. A random-effects meta-analysis was conducted on 20 studies involving 1,323 participants. LLLT/LA showed a significant positive effect on pain relief scores compared with sham treatments (SMD -0.51, 95% CI: -0.88 to -0.13; χ2 = 31.12, I2 = 74%). Alone, the therapy showed a significant positive effect on function/disability scores (30 participants, MD -11.90, 95% CI: -17.37 to -6.43). As an add-on treatment, it showed a significant positive effect on pain relief (80 participants, MD -5.10, 95% CI: -9.31 to -0.88; χ2 = 28.99, I2 = 97%) and improved function/disability scores (120 participants, MD 5.44, 95% CI: 2.19 to 8.68; χ2 = 4.07, I2 = 75%). Among 20 studies, 9 studies reported no adverse events and 1 study reported mild adverse events. LLLT/LA may be an alternative or add-on treatment for NCLBP.

Adaptable Center Detection of a Laser Line with a Normalization Approach using Hessian-matrix Eigenvalues

  • Xu, Guan;Sun, Lina;Li, Xiaotao;Su, Jian;Hao, Zhaobing;Lu, Xue
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.317-329
    • /
    • 2014
  • In vision measurement systems based on structured light, the key point of detection precision is to determine accurately the central position of the projected laser line in the image. The purpose of this research is to extract laser line centers based on a decision function generated to distinguish the real centers from candidate points with a high recognition rate. First, preprocessing of an image adopting a difference image method is conducted to realize image segmentation of the laser line. Second, the feature points in an integral pixel level are selected as the initiating light line centers by the eigenvalues of the Hessian matrix. Third, according to the light intensity distribution of a laser line obeying a Gaussian distribution in transverse section and a constant distribution in longitudinal section, a normalized model of Hessian matrix eigenvalues for the candidate centers of the laser line is presented to balance reasonably the two eigenvalues that indicate the variation tendencies of the second-order partial derivatives of the Gaussian function and constant function, respectively. The proposed model integrates a Gaussian recognition function and a sinusoidal recognition function. The Gaussian recognition function estimates the characteristic that one eigenvalue approaches zero, and enhances the sensitivity of the decision function to that characteristic, which corresponds to the longitudinal direction of the laser line. The sinusoidal recognition function evaluates the feature that the other eigenvalue is negative with a large absolute value, making the decision function more sensitive to that feature, which is related to the transverse direction of the laser line. In the proposed model the decision function is weighted for higher values to the real centers synthetically, considering the properties in the longitudinal and transverse directions of the laser line. Moreover, this method provides a decision value from 0 to 1 for arbitrary candidate centers, which yields a normalized measure for different laser lines in different images. The normalized results of pixels close to 1 are determined to be the real centers by progressive scanning of the image columns. Finally, the zero point of a second-order Taylor expansion in the eigenvector's direction is employed to refine further the extraction results of the central points at the subpixel level. The experimental results show that the method based on this normalization model accurately extracts the coordinates of laser line centers and obtains a higher recognition rate in two group experiments.

Linearly Polarized 1-kW 20/400-㎛ Yb-doped Fiber Laser with 10-GHz Linewidth (선편광된 10 GHz 선폭의 1 kW급 20/400-㎛ 이터븀 첨가 광섬유 레이저)

  • Jung, Yeji;Jung, Minwan;Lee, Kangin;Kim, Taewoo;Kim, Jae-Ihn;Lee, Yongsoo;Cho, Joonyong
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.120-125
    • /
    • 2021
  • We have developed a linearly polarized high-power Yb-doped fiber laser in the master oscillator power amplifier (MOPA) scheme for efficient spectral beam combining. We modulated the phase of the seed laser by pseudo-random binary sequence (PRBS), with the bit length optimized to suppress stimulated Brillouin scattering (SBS), and subsequently amplified seed power in a 3-stage amplifier system. We have constructed by coiling the polarization-maintaining (PM) Yb-doped fiber, with core and cladding diameters of 20 ㎛ and 400 ㎛ respectively, to a diameter of 9-12 cm for suppression of the mode instability (MI). Finally, we obtained an output power of 1.004 kW with a slope efficiency of 83.7% in the main amplification stage. The beam quality factor M2 and the polarization extinction ratio (PER) were measured to be 1.12 and 21.5 dB respectively. Furthermore, the peak-intensity difference between the Rayleigh signal and SBS signal was observed to be 2.36 dB in the backward spectra, indicating that SBS is successfully suppressed. In addition, it can be expected that the MI does not occur because not only there is no decrease in slope efficiency, but also the beam quality for each amplified output is maintained.