Removal of Nano-scaled Fluorescence Particles on Wafer by the Femtosecond Laser Shockwave (펨토초레이저 충격파에 의한 형광 나노입자 제거)

  • Park, Jung-Kyu;Cho, Sung-Hak;Kim, Jae-Gu;Chang, Won-Seok;Whang, Kyung-Hyun;Yoo, Byung-Heon;Kim, Kwang-Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.150-156
    • /
    • 2009
  • The removal of tiny particles adhered to surfaces is one of the crucial prerequisite for a further increase in IC fabrication, large area displays and for the process in nanotechnology. Various cleaning techniques (wet chemical cleaning, scrubbing, pressurized jets and ultrasonic processes) currently used to clean critical surfaces are limited to removal of micrometer-sized particles. Therefore the removal of sub-micron sized particles from silicon wafers is of great interest. For this purpose various cleaning methods are currently under investigation. In this paper, we report on experiments on the cleaning effect of 100nm sized fluorescence particles on silicon wafer using the plasma shockwave occurred by femtosecond laser. The plasma shockwave is main effect of femtosecond laser cleaning to remove particles. The removal efficiency was dependent on the gap distance between laser focus and surface but in some case surface was damaged by excessive laser intensity. These experiments demonstrate the feasibility of femtosecond laser cleaning using 100nm size fluorescence particles on wafer.

ANALYSIS OF CLINICAL EFFECT OF $CO_2$ LASER ILLUMINATION AFTER SURGICAL EXTRACTION OF IMPACTED 3RD MOLAR (하악 매복치 발치 후 $CO_2$ laser 조사의 임상적 효과 분석)

  • Kim, In-Soo;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.349-352
    • /
    • 2001
  • Dental laser provides many advantages to the clinicians. Those are excellent hemostatic effect, good operating sight, minimal adjacent tissue injury, reduction of postoperative swelling & pain, reduction of postoperative infection, reduction of scar tissue & contraction, etc. The purpose of this study is to observe how these advantages work after surgical extraction of impacted third molar. From march 2000 to july 2000, we have randomly divided the patients who had been surgically extracted unilateral impacted third molar into two groups. The first group comprised $CO_2$ laser illumination with 3 watts, defocusing & continuous mode, rotating motion for about 3 minutes after finishing of surgical extraction & suture. The other group patients were not irradiated. The medications in two groups were same. We measured pain, swelling and trismus three times(pre-operation, first day after operation, and 7th day after operation). The number of the patients who had measured three times all are 64, laser irradiated groups are 36 and non-irradiated groups are 28. The age ranged from 19 to 50, with a mean of 27.9 years. The operative time ranged from 3 minutes to 50 minutes, with a mean of 12.1 minutes. In the $CO_2$ laser group, the pain intensity of the 7th day after operation was still increased significantly comparing with that of the pre-operation and the distance which were measured for the swelling was different significantly. In the other group, the mouth opening limitation was still decreased significantly.

  • PDF

Detection Robustness Enhancement and Utility Scheme of Alternating Automotive Dual Beam Laser Radar (합차신호를 이용한 차량용 듀얼 빔 레이저 레이더의 견고한 탐지 능력 향상 방안)

  • Lee Seung-Gi;Yoo Seung-Sun;You Kang-Soo;Kim Sam-Tek
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.743-754
    • /
    • 2006
  • In the proposed method, two regular laser working at two different wavelengths perform moving object detection alternatively in time. The laser intensity and the beaming period of each laser is equally maintain as to the single laser radar, hence, externally, dual beam lasers radar works exactly same as the single beam laser radar except that the proposed dual lasers radar needs additional post-processing of received signals in the receiver. To verify the robustness of the proposed method, a set of computer simulation has been performed. The communication channel is assumed to be additive white Gaussian noise, and the perfect synchronization is assumed. All other simulation parameters such as signal power and signalling period are equally maintain in both systems while the signal processing time such as spreading and filtering are expected to be trivial in call cases.

A study on selective hybrid-structure film fabricated by 355nm UV-pulsed laser processing (355nm UV 레이저를 이용한 선택적 하이브리드 구조 필름의 제작에 관한 연구)

  • Kim, Myung-Ju;Lee, Sang-Jun;Shin, Bo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.2979-2984
    • /
    • 2015
  • This paper has presented a new foaming technology of selective hybrid-structured polymer film with expanded pores. The porous structure of closed pore was firstly fabricated by applying the 355nm UV-pulsed laser to 0.1mm thick film that was uniformly mixed with PP pellets, copper powder, and CBA (Chemical Blowing Agent). In order to expand pore size of closed-cell shape, LAMO(Laser Aided Micro pore Opening) processing was conducted to heat the copper powder, and then the bigger pore size of closed-cell more than existing pore size was successfully formed because of rapid conduction of heated metal powder. From the experimental results, various process parameters such as laser fluence, intensity, scan rate, spot size and density of powder and CBA were considerably considered to reveal the correlation among the pore characteristics. In the future, a function experiment will be carried out to use the hybrid film of industrial applications.

The effects of low level laser radiation on bacterial growth

  • Chung, Wendy;Petrofsky, Jerrold S.;Laymon, Michael;Logoluso, Jason;Park, Joon;Lee, Judy;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • Objective: The low level lasers currently in the market vary in wavelength, dosage, and frequency. These devices are used with much different clinical pathology. Most notably, some studies claim that wounds heal faster with low level laser therapy due to the fact that bacteria commonly found in wounds are killed by laser light. Systemic and meta-analysis studies found the difficulty of comparison of numerous research studies because of differences in the intensities and frequencies of low level laser treatment (LLLT). The purpose of this study was to determine the effectiveness of LLLT on controlling bacterial growth. Design: Cross-sectional study. Methods: Variables included LLLT dosage and wavelength on 3 bacteria commonly seen in wounds, strains of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were used on commercially available 5.0-cm agar plates. Blue, green, and red, ultraviolet (UV) and infrared laser light sources were adjusted to either low or high intensity settings. Five Petri dishes at a time were placed directly beneath laser light sources with the exception of UV which was placed six inches below the suspended light and infrared which was placed directly on top of the Petri dish lid. Each group of five Petri dishes was irradiated for 15 minutes. Results: The results showed no effect of any of 9 different LLLT intensities or colors on bacteria growth compared to sham light. Conclusions: At least for claims of bacterial growth inhibition with LLLT, no support for this claim can be found here.

A Study on the Measurements of Beam Wave Propagation and Fluorescence Spectroscopy in Particles Media (입자매질에서 빔파동전파와 형광분광 측정에 관한 연구)

  • Kim, Ki-Jun;Lee, Jou-Youb;Sung, Wan-Mo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.167-175
    • /
    • 2014
  • The influences of fluorescence, scattering, and flocculation in turbid material were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence(LIF). The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used in Photodynamic therapy. The interactions of several colloid particles can come into play which have major effect on the flocculation and LIF process. We measured scattering and fluorescence spectra of the sample for in vitro as function of concentration from lase source to detector. The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer. Therefore, Phorphyrin A is larger than Phorphyrin C in scattering intensity ${\mu}_s$, but Phorphyrin A is smaller than Phorphyrin C in penetration depth ${\delta}$.

Effect of Surface Damage of Metal Substrate on LIBS Signal (금속 Substrate의 표면손상이 LIBS신호에 미치는 영향)

  • Jang, Sang-Ik;Kim, Kibum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1259-1264
    • /
    • 2014
  • Hydrogen is in the world limelight for future energy source, and it has been already used in various industry fields including aerospace. The extremely fine molecule of the hydrogen can be easily leaked from tiny size of the crack on the surface of transporting pipes or storage tanks, and it could bring on awfully terrible disaster. In this study, Laser-Induced Breakdown Spectroscopy (LIBS) was employed to develope a reliable detection scheme for a small quantity of hydrogen leakage. Effect of three different metal substrates (i.e. Al, Cu, SUS) on plasma generation and the intensity of the hydrogen atomic signal was investigated, and the surface damage of the substrates due to repetitive laser shots was observed using Scanning electron microscope. It was also evaluated how the surface damage could distort the atomic signal. The intensity of the atomic signal was found to be the strongest, and the signal distortion due to the surface damage was approximately $100W/m^2$ lower when Al was used for the substrate.

Systemic and local effects of doxycycline and low-intensity laser treatment on periodontitis in rats

  • Silveira, Glauco Rodrigues Carmo;Lima, Daniela Coelho de;Cintra, Luciano Tavares Angelo;Brigagao, Maisa Ribeiro Pereira Lima;Ervolino, Edilson;Fernandes, Leandro Araujo
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.1
    • /
    • pp.39-53
    • /
    • 2022
  • Purpose: This study evaluated the systemic and local effects of doxycycline (DOX) and low-intensity laser (LIL) treatment as adjuvants to scaling and root planing (SRP) in the treatment of experimental periodontitis in rats. Methods: The sample consisted of 180 male rats (Rattus norvegicus albinus, Wistar), of which 30 did not receive induction of periodontal disease (negative control [NC] group) and 150 received induction of periodontal disease in the lower first molar. After 7 days, the ligature was removed, and the animals were divided into the following groups: NT (no treatment), SRP (SRP), DOX (SRP and DOX irrigation), LIL (SRP and laser irradiation), and DOX+LIL (SRP, DOX, and LIL). The animals were euthanized at 7, 15, and 30 days; thereafter, biochemical, radiographic, histological, and immunohistochemical analyses were performed. Results: In the intragroup analysis, lower concentrations of α-1-glycoprotein acid (α-1-Ga) and complement 3 (C3) were observed in the DOX+LIL group than in all other groups at all time points, as well as lower levels of complement 4 (C4) at 15 and 30 days (P<0.001). Less bone loss was observed in the DOX, LIL, and DOX+LIL groups than in the NC and SRP groups at all time points (P<0.001). There was a smaller number of tartrate-resistant acid phosphatase (TRAP)-positive cells in the DOX+LIL group than in the other groups at all time points (P<0.001). Positive correlations were observed between the systemic levels of α-1-Ga, C3, and C4 and the number of TRAP-positive cells. Conclusions: The combination of DOX with LIL as SRP adjuvants was effective both systemically and locally for the treatment of experimental periodontitis in rats.

The Effects of Transcutaneous Electrical Nerve Stimulation and Ultrasound Treatment Combined with High Intensity Laser Treatment on Pain, Grip Strength, and Hand Function in Patients with Carpal Tunnel Syndrome

  • Jawon Kim;Myunggi Cho;Yijung Chung
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.231-239
    • /
    • 2024
  • Objective: This study was conducted to investigate the effect of high-intensity laser therapy(HILT), transcutaneous electrical nerve stimulation(TENS), and ultrasound(US) treatment on pain, grip strength, and hand function in patients who had undergone carpal tunnel syndrome surgery. Design: A randomized controlled trial. Methods: Thirty patients who had undergone carpal tunnel syndrome surgery were randomly assigned to receive either TENS combined with HILT, US combined with HILT, or only HILT as the control group. Treatments were applied around the surgical site, and pre- and post-treatment changes were evaluated. Pain was assessed using NPRS, hand symptoms using CTS-6 and BCTQ-SSS, grip strength with an electronic dynamometer, and hand function using BCTQ-FSS. Treatments were administered seven times over two weeks. Results: The pain and symptoms were significantly reduced(p<0.05) and grip strength and hand function were significantly increased(p<0.05) after treatment compared to before treatment for all subjects. Pain was significantly reduced(p<0.05) and grip strength was significantly increased(p<0.05) in the TESN+HILT group and US+HILT group compared to the Control group. Hand symptoms were significantly reduced(p<0.05) and hand function significantly increased(p<0.05) in the TENS+HILT group compared to the Control group. Conclusions: TENS combined with HILT was found to be more effective than US combined with HILT in reducing pain and symptoms and improving grip strength and hand function in patients following carpal tunnel syndrome surgery. These findings suggest that these treatment modalities can be beneficially applied in clinical practice.

Development of a Measuring Instrument for the Coefficient of Luminous Intensity of Retro-Reflection of Miniature Telecentric Cameras (소형 텔레센트릭 카메라 광학계의 재귀반사 측정 방법 연구 및 측정 장치 개발)

  • Yeo, TaeWoon;Karasik, V.E.;Kim, Young Il
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.334-339
    • /
    • 2014
  • In this paper, the optical properties of a miniature telecentric camera are studied analytically and experimentally. By means of optical properties, the luminous intensity of retro-reflection of a miniature telecentric optical system is investigated. First, from a simulation the theoretical value of the coefficient of luminous intensity of retro-reflection of a miniature telecentric system is estimated. Second, a miniature telecentric camera device is designed, and the value of the coefficient of luminous intensity of retro-reflection of the actual device is measured through experiment. From simulation and experiment, we found that both the estimated and observed values of the coefficient of luminous intensity of retro-reflection range from 0.002 to $0.03m^2/sr$ (P384200CPH: $0.0042-0.018m^2/sr$, P285200CPH: $0.0045-0.0297m^2/sr$, P321450S: $0.0021-0.00963m^2/sr$) at 1.4 to 4.9 arcminute. The results prove the significance of the mechanisms used to design the miniature telecentric camera, and the experimental method. Accordingly, with these significant results, this study contributes to the development of theory and practice in optical engineering science.