• Title/Summary/Keyword: laser beam

Search Result 2,057, Processing Time 0.026 seconds

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

Short-term Results of Endobronchial Brachytherapy for Malignant Airway Obstructions (악성 기도 폐쇄에 대한 기관내 근접 조사 방사선치료의 단기 임상 경험)

  • Ahn Yong Chan;Lim Do Hoon;Choi Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Kim Ho Joong;Chung Man Pyo;Kwon O Jung;Rhee Chong Heon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.299-306
    • /
    • 1996
  • Purpose : Respiratory symptoms related with malignant airway disease have been the main causes of lowered qualify of life and also sometimes may be life-threatening if not properly managed. The authors report the short-term experiences of endobronchial brachytherapy for symptomatic malignant airway obstruction using high dose rate after-loading brachytherapy unit. Materials and Methdos : Twenty-five Patients with symptomatic malignant airway obstruction were treated with endobronchial brachytherapy between the period of December 1994 and March 1996 at Department of Radiation Oncology of Samsung Medical Center Twenty-one ($84\%$) were patients with non-small cell lung cancer, three with tracheal malignancies, and one with recurrence of esophageal cancer. Twenty Patients were given elective external beam radiation therapy, while six were given endobronchial laser evaporation therapy on emergency bases in addition to endobronchial brachytherapy. Three procedures for each patient were planned and total of 70 procedures were completed. Results : Improvement rates of major respiratory symptoms after endobronchial brachytherapy procedures were $88\%$(22/25). $96\%$(22/23), $100\%$ (15/15), and $100\%$(9/9) for cough, dyspnea, hemoptysis and obstructive pneumonia, respectively. ECOG performance scores were improved in $56\%$ of total patients group, while there was no case with worsened ECOG score. Fifteen patients died and the median interval from the start of treatment to death was 4 months (range: $1\~17$ months), while that of ten survivors was 9 months (range $5\~19$ months). There were five patients with controlled intrathoracic disease, who have survived over one rear. All deaths were associated with uncontrolled local and/or distant disease. Four Patients died of massive fatal hemoptysis, three of who received emergency endobronchial laser evaporation therapy before the start of endobronchial brachytherapy. Conclusion : Endobronchial brachytherapy has been confirmed as an excellent palliative treatment modality improving respiratory symptoms as well as patients' general performance status. Based on the current observations, use of endobronchial brachytherapy in curative setting as a boost technique may be warranted.

  • PDF

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

Measurement of picosecond laser pulsewidth and pulseshape by two-photon fluorescence and noncolloinear type I second harmonic generation method (이광자 형광법과 비공선 일종 이차고조파법에 의한 피코초 레이저 펄스폭과 펄스형 측정)

  • 한기호;박종락;이재용;김현수;엄기영;변재오;공흥진
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.251-259
    • /
    • 1996
  • Two-Photon Fluorescence (TPF) experiment measures temporal width of an amplified short laser pulse which has passed through a four-pass Nd: glass amplifier, after selecting a single pulse from pulse train Q-switched and mode-locked(QSML) in Nd:YLF master oscillator. Determination of pulsewidth and pulseshape was also made with detection of autocorrelation trace of CW mode-locked pulse train by using noncollinear type I Second Harmonic Generation (SHG) method. The observed TPF track showed various patterns, depending on pulse-selecting position in QSML pulse train. That is, autocorrelation of a pulse extracted at front of the train displayed smooth pulse shape, while one from the trailing part of the train created many sharp spikes and substructure in the pulse. By TPF method, pulsewidth was measured to be 44.4 ps with contrast ratio of 2.86 which enabled us to find out energy fraction of a pulse to total energy, (sum of pulse and background); we obtain the value of 0.62. Pulsewidth of 46.6ps was also acquired in another SHG experiment with the help of only mode-locked pulse train. On the other hand, we confirmed that shape of the pulse is close to $sech^2$ one as a result of fitting the SHG autocorrelation signal with various functions. With simulation using this $sech^2$ type of pulse, pulsewidth reduction of the beam, having passed through four-pass amplifier, was also verified.

  • PDF

Ohmic Contact of Ti/Au Metals on n-type ZnO Thin Film (Ti/Au 금속과 n-type ZnO 박막의 Ohmic 접합 연구)

  • Lee, Kyoung-Su;Suh, Joo-Young;Song, Hoo-Young;Kim, Eun-Kyu
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.339-344
    • /
    • 2011
  • The Ohmic contact of Ti/Au metals on n-type ZnO thin film deposited on c-plane sapphire substrates by pulsed laser deposition was investigated by TLM (transfer length method) patterns. The Ti/Au metal films with thickness of 35 nm and 90 nm were deposited by electron-beam evaporator and thermal evaporator, respectively. By using the photo-lithography method, the $100{\times}100{\mu}m^2$ TLM patterns with $6{\sim}61{\mu}m$ gaps were formed. To improve the electrical properties as well as to decrease an interface states and stress between metal and semiconductor, the post-annelaing process was done in oxygen ambient by rapid thermal annealing system at temperature of $100{\sim}500^{\circ}C$ for 1 min. In this study, it appeared that the minimum specific contact resistivity shows about $1.1{\times}10^{-4}{\Omega}{\cdot}cm^2$ in $300^{\circ}C$ annealed sample, which may be originated from formation of oxygen vacancies of ZnO during an oxidation of Ti metal at the interface of Ohmic contacts.

Interstitial Photodynamic Therapy (PDT) Set-up for Treating Solid Tumor Using Laser Diode (레이저 다이오드를 이용한 고형암 치료를 위한 간질성 광역학 치료법 개발)

  • Kim Jong-Ki;Kim Ki-Hong
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.104-109
    • /
    • 2005
  • Photodynamic therapy (PDT) is one of the expectable current cure operation methods. Tumor tissue is treated by abundant oxygen in a body and generated singlet or free radical from exterior laser diode and photosensitizer. Current problem of PDT is the low penetration power of the light beam in a deep seated large tumor and solid tumor thus results in low treatment outcome. In the study, we tried to develop interstitial photodynamics therapy treatment to solve this problem. As the accurate determination of light dosimetry in biological tissue is one of the most important factors affecting the effectiveness of PDT, parameters used in this study are the optical property of biological tissue. Since biological tissues have large scattering coefficient to visible light the penetration depth of a biological tissue in visible light region is only $15\~20$ mm. We showed that it is possible to measure fluence rate and penetration depth within the biological tissues by Monte Carlo simulation very well. Based on the MC simulation study, the effectiveness of interstitial photodynamic therapy on tumor control in solid tumor was proved through in vivo animal experiment.

  • PDF

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책)

  • Kwon, Soon-Tae;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.189-197
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the interference of Mie scattering, which is main obstacle of the measuring concentration with Rayleigh scattering, a hardware filter was installed for reducing the number density of particles. Furthermore a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. In addition, background noisy was reduced by adjusting the optical array and applying the pin hall and beam trap. The results show that LRS can provide useful information about concentration field and the software filter is very effective method to remove Mie interference.

Stimulated Raman scattering at 1.54${\mu}m$ and Brillouin scattering at 1.06${\mu}m$ in $CH_4$ under 5 Hz repetition rate (반복률과 라만매질 압력에 따른 1.54 ${\mu}m$ 전방, 후방 유도라만 및 1.06${\mu}m$ Brillouin 산란광의 출력특성)

  • 최영수;전용근;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • We have studied the 1.54$\mu\textrm{m}$ forward and backward stimulated Raman scattering (SRS) and stimulated Brillouin scattering (SRS) for various $CH_4$pressures by 1.06$\mu\textrm{m}$ Q-switched Nd:YAG laser pumping under a repetition rate of Hz in single pass. We obtained that the output of backward SRS was more efficient than that of the forward SRS. The output energy and conversion efficiency of forward and backward SRS were higher than those of SBS since SRS is a steady state, but SBS is a transient state. In a $CH_4$gas uncirculating system, the output energy of the backward SRS and SBS were reduced the about 47% due to a thermal heating of $CH_4$medium in a focusing region for a repetition rate of 5 Hz. But, the output energy of forward SRS was slightly enhanced by about 8.5% due to the increase of the undepleted pump beam in the backward SRS generation. Inthe Raman half resonator using a dichromatic focusing lens, the conversion efficiency of SRS was more than 37% for a input pump laser energy of 40 mJ.

  • PDF

Fabrication of a Mach-Zehnder interferometer for education using a rotating glass plate and a 3D printer (회전 유리판과 3D 프린터를 이용한 교육용 마흐젠더 간섭계 제작)

  • Jang, Seong-Hun;Ju, Young-G
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.213-220
    • /
    • 2017
  • This paper proposes how to fabricate an educational Mach-Zehnder interferometer that is easy to align and inexpensive, using 3D printers and semiconductor lasers. The interferometer consists of a body $165mm{\times}120mm{\times}57mm$ in size, mirror mounts, a laser holder, beam splitters, and so on. The laser path is adjusted by 4 mirror mounts, each comprised of rubber bands, small metal wires, and a screw. The interference fringe is enlarged by the lens at the final stage. The refractive index of a slide glass was measured by counting the number of moving interference fringes while the slide glass, inserted into one of the two interferometer arms, is rotating. The formula for the refractive index as a function of the optical-path difference and rotation angle was obtained, and used to calculate the refractive index of glass from the interferometer experiment. The use of a rotating glass in one arm of the interferometer nullifies the need for a precision stage, which despite its high cost is often required to observe the moving interference fringe in the classroom. Therefore, the 3D-printed Mach-Zehnder interferometer proposed in this paper can be very useful for education, because of its affordability and performance. It enables students to perform both qualitative and quantitative studies using a 3D-printed interferometer, such as measuring the refractive index of a glass sample, and the wavelength of light.