• 제목/요약/키워드: laser Doppler

검색결과 480건 처리시간 0.032초

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

치근 발육정도와 Laser Doppler Flowmeter 측정치의 상호 관련성 (RELATIONSHIP BETWEEN LASER DOPPLER FLOWMETER OUTPUT AND STAGE OF ROOT DEVELOPMENT)

  • 서완종;김현정;김영진;남순현
    • 대한소아치과학회지
    • /
    • 제26권2호
    • /
    • pp.437-445
    • /
    • 1999
  • 외상받은 치아의 치수 생활력을 조기에 진단하는 것은 매우 중요하다. 그러나 대부분의 경우 치수생활력을 조기에 알 수 없으며, 특히 미완성 치근단을 가진 치아에서는 치수생활력 검사의 신뢰도는 더욱 낮아진다. 본 연구는 미완성 치근단을 가진 치아를 대상으로 하여 치근단 완성도에 따른 Laser Doppler Flowmeter(이하 LDF)의 측정치 차이와 발육단계에 따른 각각 LDF 측정 기준치를 알아 보고자 하였다. 이를 위하여 23세에서 24세 성인 남녀 20명 및 7세에서 8세 취학 아동중 치근단공의 크기가 2mm이상인 아동 20명, $1{\sim}2mm$인 아동 20명의 상악 좌우중절치를 대상으로 LDF검사를 시행하였다. LDF는 안정된 signal이 나타날 때 까지 5분이상 관찰하였으며, 안정상태 도달후 5분이상 측정하였다. 모든 반응인자의 정규분포를 확인한 다음, 각 시험군간의 LDF측정치를 ANOVA test를 이용하여 비교하였고, 동일대상에서 좌우 치아간의 비교는 paired-t test를 이용하여 다음과 같은 결론을 얻었다. 1. LDF측정치에 있어 미완성 치근단을 가진군이 완성된 치근단을 가진 군에 비해 높게 나타났지만 통계학적으로 유의한 차이는 나타나지 않았다 (p>0.05). 2. 미완성 치근단을 가진 군간의 비교시 LDF측정치에 있어 통계학적으로 유의한 차이는 나타나지 않았다 (p>0.05). 3. 각 실험군내에서 좌우중절치간의 비교시 LDF측정치에 있어 통계학적으로 유의한 차이는 나타나지 않았다 (p>0.05).

  • PDF

치수생활력 검사 방법으로서 laser Doppler flowmeter의 신뢰도 (THE RELIABILITY OF LASER DOPPLER FLOWMETER IN PULP VITALITY TEST OF TEETH)

  • 남동우;김영진;남순현
    • 대한소아치과학회지
    • /
    • 제25권4호
    • /
    • pp.683-690
    • /
    • 1998
  • 미완성 치근을 가진 영구 중절치에 대한 치수생활력검사에서 LDF의 신뢰도를 알아보기 위해 8-9세의 취학 아동 35명을 대상으로 전기치수검사 및 LDF에 의한 치수생활력 검사를 시행하고 대조군으로 23-24세 성인 남녀 35명의 상악 영구중절치를 대상으로 동일한 검사를 시행하였다. 미완성 치근단을 가진 치아는 방사선 사진상 Moorrees 등의 연구를 참조하여 치근 발육 5 및 6 단계로 한정하였다. 전기치수검사는 최초의 감각이 나타나는 시기를 역치로 정하였으며, 대상 치아당 3회 이상 실시하였고, 위음성 반응의 가능성 때문에 검사간 간격은 3분 이상으로 하였다. LDF는 안정된 signal이 나타날 때 까지 5분 이상 관찰하였으며, 안정상태 도달 후 5분 이상 측정하였다. 모든 반응인자의 정규 분포를 확인한 다음, 대조 치아 및 시험 치아간 LDF 및 전기치수검사의 역치를 student t-test를 이용하여 비교하였다. 1. 전기치수검사시 미완성 치근에서는 28.4%에서만 반응이 나타났으며, 완성 치근의 경우 100%에서 반응이 나타났고, LDF에 의한 검사시 미완성 치근 및 완성 치근 모두에서 100% 반응이 나타났다. 2. 완성 치근 및 미완성 치근을 가진 치아의 전기 치수검사 역치는 미완성 치근을 가진 치아가 큰 값을 나타내며 유의한 차이가 있었다 (p<0.01). 3. 완성 치근 및 미완성 치근을 가진 치아 사이의 LDF 수치는 유의한 차이가 나타나지 않았다 (p>0.05).

  • PDF

Laser Doppler Flowmetry를 이용한 치은혈류량에 관한 연구 (A study of gingival blood flow using laser Doppler flowmetry)

  • 김형수;이장희;송형근;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.309-320
    • /
    • 1998
  • The periodontal health has been evaluated clinically by various epidemiological indices, and in researches by measurement of gingival crevicular fluid. Laser Doppler flowmetry is a reliable and objective method that allows immediate measurement of erythrocyte flux in approximately one cubic mm of the capillary bed without disturbing the tissues. The purpose of the present study was to determine whether human gingival blood flow was different according to measuring area, measuring time, and sex or not. Forty volunteers with good general and periodontal health, aged early twenties and unmarried, were selected. Laser Doppler flowmetry($floLAB^{(R)}$, Moor Instruments Ltd., England) was applied to measure the gingival blood flow of marginal gingiva, interdental papilla, attached gingiva and alveolar mucosa. The blood flow of interdental papilla was measured at 9-10 AM, 1-2 PM, and 5-6 PM. The difference of blood flow according to measuring area and measuring time was statistically analyzed by one way AOVA and Dunkan test, and the difference of blood flow between men and women was statistically analyzed by t-test. (1) Mean blood flow was significantly higher in alveolar mucosa than in the gingiva(p<0.05), and there was no significant difference in blood flow between marginal gingiva and interdental papilla(p>0.1). (2) Mean blood flow was significantly higher at 5-6 PM than at 9-10 AM and 1-2 PM(p<0.05). But there was no significant difference in gingival blood flow between 9-10 AM and 1-2 PM(p>0.1). (3) There was no significant difference in gingival blood flow between men and women(p>0.1). The above results suggest that the measurment of gingival blood flow using laser Doppler flowmetry may be clinically applicable to early determination of gingival inflammation and evaluation of healing status, but further studies are necessary to standardize and simplify the measuring procedure.

  • PDF

ESPI에 의한 레이저용접 조건에 따른 진동 특성 분석 (Vibration Characteristics Analysis as Laser Welding Condition by ESPI)

  • 김경석;정현철;백상규;이유황;유득남
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.349-353
    • /
    • 2005
  • This paper describes the variations of resonance frequencies and vibration mode shapes of laser welded cold rolled carbon steel plate(SCP1) induced by thermal loading during laser welding processing. The characteristics of those are analyzed with stroboscopic ESPI. Electronic speckle pattern interferometry (ESPI) that the electronic processes were added to SPI is one of the very powerful method in the experimental vibration analysis field. Stroboscopic ESPI to make it reliable are compared with theory and experimental method: Finite Element Method(FEM) and Scanning Laser Doppler Vibrometer(SLDV). The results of stroboscopic ESPI are well agreed with SLDV and also the comparison with theory give good agrement within $5\%$.

  • PDF

평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구 (Development of An Automated Scanning Laser Doppler Vibrometer For Measurements of In-Plane Structural Vibration)

  • 길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.422-430
    • /
    • 1996
  • The automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane displacements associated with waves propagating on vibrating structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

초음파 Doppler법에 의한 생체 경조직의 비침투적인 진단을 위한 기초실험 (A Method for Noninvasive Diagnosis of Bone using Ultrasonic Doppler Method)

  • 박무훈
    • 한국음향학회지
    • /
    • 제17권7호
    • /
    • pp.3-11
    • /
    • 1998
  • 본 논문에서는 분포정수선로의 간단한 모델을 이용해서, 외부에서 진동을 가했을 때 에 뼈 표면에서 발생하는 굴곡파의 전파속도와 종파의 전파속도를 구할 수 있는 새로운 측 정원리를 제안했다. 이 측정원리를 이용해서, 봉(brass, polymethylmethacrylate)표면에 발생 하는 정재파에 대한 속도의 공간분포를 laser Doppler법으로 측정해서, 각각의 주파수에 대 한 전파속도를 구했다. 이 새로운 측정방법은 in vivo에서 초음파 Doppler법을 이용해서 뼈 의 이상(골다공증, osteoporosis)진단의 가능성을 제시했다.

  • PDF

Velocity measurements in complex flows of non-Newtonian fluids

  • Muller, Susan J.
    • Korea-Australia Rheology Journal
    • /
    • 제14권3호
    • /
    • pp.93-105
    • /
    • 2002
  • Experimental methods for making quantitative measurements of velocity fields in non-Newtonian fluids are reviewed. Techniques based on light scattering spectroscopy - laser Doppler velocimetry and homodyne light scattering spectroscopy, techniques based on imaging the displacement of markers - including particle image velocimetry and molecular tagging velocimetry, and techniques based on nuclear magnetic resonance imaging are discussed. The special advantages and disadvantages of each method are summarized, and their applications to non-Newtonian flows are briefly reviewed. Example data from each technique are also included.

레이저 다이오드의 자기혼합 효과를 이용한 조직혈류 측정에 관한 연구 (A Study on the Measurement of Tissue Blood Flow by the Self-Mixing Effect of Laser Diode)

  • 고한우
    • 센서학회지
    • /
    • 제3권2호
    • /
    • pp.57-64
    • /
    • 1994
  • 레이저 다이오드의 자기혼합 효과를 이용한 조직혈류측정을 위한 기초연구를 하였다. 이동물체로 인한 레이저 도플러 신호를 자기혼합 효과에 의해 검출하였으며, 피검자의 인지로부터 비관혈적으로 조직의 혈류 변화를 측정할 수 있었다. 이동 물체의 이동속도가 변함에 따라 자기혼합 효과에 의한 도플러 편이 주파수는 선형적으로 변하였으며, in-vivo 실험의 인지에서 측정된 토플러 신호는 운동후의 주파수가 운동전의 주파수 보다 높았으며, 이는 운동생리학적인 결과와도 일치하였다.

  • PDF