• Title/Summary/Keyword: large-scale structure

Search Result 1,322, Processing Time 0.029 seconds

Deflection of Ultra-high Energy Cosmic Rays by the Galactic Magnetic Field

  • Kim, Jihyun;Kim, Hang Bae;Ryu, Dongsu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.73.1-73.1
    • /
    • 2014
  • We investigate the influence of the galactic magnetic field (GMF) on the arrival direction (AD) of ultra-high energy cosmic rays (UHECRs) by searching the correlation with the large-scale structure (LSS) of the universe. The deflection angle of UHECRs from sources by the GMF is reflected in a source model by introducing the Gaussian smearing angle as a free parameter. Assuming the deflections by the GMF are mainly dependent on the galactic latitude, b, we divide the regions of sky by b and analyze the correlation between the AD of UHECRs and the LSS of the universe in each region varying the smearing angle. We find the deflection is strongly dependent on the galactic latitude by the maximum likelihood estimation. Specifically, the best-fit smearing angles are $9^{\circ}$ and $84^{\circ}$ in the high galactic latitude (HGL), $-90^{\circ}$ < b < $-60^{\circ}$, and in the low galactic latitude (LGL), $-30^{\circ}$ < b < $30^{\circ}$, respectively. The strength of GMF becomes stronger from the HGL to the LGL. From the results, we can estimate the strength of GMF in each region. In the LGL, for example, if we assume UHECRs are protons, we have the order of $100{\mu}G$ GMF, which is much stronger than the expected value of conventional GMF model. However, if the primaries are heavy nuclei, which is consistent with the observational result of mass composition analysis, the order of GMF strength is a few ${\mu}G$. More data from the future experiments make it possible to study the GMF between the source of UHECRs and Earth more accurately.

  • PDF

Testing Weak-Lensing Maps of Galaxy Clusters with Dense Redshift Surveys Testing Weak-Lensing Maps of Galaxy Clusters with Dense Redshift Surveys

  • Hwang, Ho Seong;Geller, Margaret J.;Diaferio, Antonaldo;Rines, Kenneth J.;Zahid, H. Jabran
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.54-54
    • /
    • 2014
  • We use dense redshift surveys of nine galaxy clusters at z ~ 0.2 to compare the galaxy distribution in each system with the projected matter distribution from weak lensing. By combining 2087 new MMT/Hectospec redshifts and the data in the literature, we construct spectroscopic samples within the region of weak-lensing maps of high (70-89%) and uniform completeness. With these dense redshift surveys, we construct galaxy number density maps using several galaxy subsamples. The shape of the main cluster concentration in the weak-lensing maps is similar to the global morphology of the number density maps based on cluster members alone, mainly dominated by red members. We cross correlate the galaxy number density maps with the weak-lensing maps. The cross correlation signal when we include foreground and background galaxies at 0.5zcl < z < 2 zcl is 10 - 23% larger than for cluster members alone at the cluster virial radius. The excess can be as high as 30% depending on the cluster. Cross correlating the galaxy number density and weak-lensing maps suggests that superimposed structures close to the cluster in redshift space contribute more significantly to the excess cross correlation signal than unrelated large-scale structure along the line of sight. Interestingly, the weak-lensing mass profiles are not well constrained for the clusters with the largest cross correlation signal excesses (>20% for A383, A689 and A750). The fractional excess in the cross correlation signal including foreground and background structures could be a useful proxy for assessing the reliability of weak-lensing cluster mass estimates.

  • PDF

A Study on the Chloride Migration Properties of High Durable Marine Concrete Using the Expansion Production Admixture (팽창재를 혼입한 고내구성 해양콘크리트의 염화물 확산특성에 관한 연구)

  • Kim, Kyoung-Min;Ryu, Dong-Woo;Park, Sang-Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.697-700
    • /
    • 2008
  • Recently, high strength, flowability, and durability of concrete were required according to increase of large scale and high rise structure. However, cracks occurred easily on the high performance concrete. In this reason, using expansion agent for reducing shrinkage cracks were increased, but it did not consider on durability of high performance concrete. Accordingly, this study1 investigated the resistance of shrinkage and damage form salt by mixing CSA expansion agent on the blast-furnace slag cement and mixed cement for the low heat of hydration by three components. The cases that 8% of expansion agent was mixed and the proportion was OPC were expanded till 43.7 times compared with control concrete. For the resistance to the damage of salt, it was improved when mixing ratio was incresed and the maximum size of coarse aggregate growed bigger. In this study, the resistance to the damage of salt of the cases that 8% of expansion agent was mixed was improved about 16% compared with control concrete.

  • PDF

Hydration Heat Analysis of Mass Concrete considering Heat Transfer Coefficient and Hydration Heat Difference (수화발열량차 및 열전달계수 변화를 고려한 매스콘크리트의 수화열 해석)

  • Han, Seung-Baek;Lee, Seong-Su;Shin, Hyo-Bum;Kim, Ho-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.249-252
    • /
    • 2008
  • In recent large-scale structures, as mass concrete type structure is frequently applied to the building, temperature crack due to hydration heat needs to be considered. Since a volume change is internally or externally restricted in a mold after placing concrete, temperature crack of mass concrete takes place. By this reason, the reduction method to control this crack is required. In this study, low heat mixture and hydration heat difference is used to execute the analysis of hydration heat, considering the changes of heat transfer coefficient according to curing conditions and block placement of mass concrete. For the analytical modelling, original portland cement and concrete of low heat mixture are placed in the upper and lower payer, respectively. A convection boundary condition is fixed because mass concrete of block placement is characterized by the difference of mold form and curing condition. Through the analysis results considering the changes of low heat mixture, block placement, and heat transfer coefficient, we check out the temperature and stress distribution and analyze the temperature crack reduction effect.

  • PDF

A Study on the Pay and Job Satisfaction of Clinical Nurses in Some Hospitals (이직율이 높은 일부 중소병원 간호사의 보수만족과 직무만족에 관한 조사연구)

  • Kim, Young-Hae;Kim, Soon-Goo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.1
    • /
    • pp.137-148
    • /
    • 1999
  • The study was attempted to survey the pay and job satisfaction of clinical nurses in some hospitals. The period was Jan 6th through Jan 27th. 1997 and the subjects were 277 nurses working in 5 hospitals in Pusan city. This study was based on questionnaires which focused on the pay and job satis faction of the nurses. The following instruments were used for collecting the data: PSQ. JDI and MSQ on the scale of 1 being lowest to 5 being highest satisfaction. The analysis of collected data was executed by using SPSS/PC+. The results were as follows: 1. The main age level was 26-30 and the portion was 44.4%. The Mean of the monyhly pay was 930 ${\pm}$130 thousand won. 2. The average point of pay satisfaction was 2.17${\pm}$.61. 3. The average point of job satisfaction was 2.87 ${\pm}$.66. 4. The factors which affect the pay satisfaction were 'the size of hospital'. 'the joining of labor unions' and 'the amount of pay' . 5. The factors which affect the job satisfaction were 'the size of hospital'. 'the job rank' and 'the amount of In conclusion, nurses are not satisfied with their job and pay levels because of the size of the hospital and the amount of pay, In order to solve the problem of turnover. medium-sized hospitals need to standardize and modify the levels of pay, the structure and the system according to standards well established by large-sized hospitals.

  • PDF

Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station (발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.213-218
    • /
    • 2017
  • High-voltage power systems operate in order to generate and transmit electric power at power stations. Compared to low-power systems, high-power systems are complex in structure, large-scale, and expensive. When high-power cable accidents occur, most facilities are incapacitated-including low-power systems-causing huge economic losses. Great care must therefore be taken in designing, installing and managing power systems. Although dependent on installation circumstances and usage conditions, in some cases the cross-sectional areas of cables fall short of the critical area due to the expansion of and improper design and installation of power facilities. In this situation, the exceeded ampacity (allowable current) above the critical value caused by the operating current initiates the deterioration processes of power cables. In order to systematically monitor power cables operating at power stations, we have developed the first device of its kind in Korea. In this paper, we present the analyzed characteristics of expected temperatures of cables based on the load current of high-voltage cables operating at Korean Western Power Co. Ltd. We can predict the lifetime of cables by analyzing the temperature obtained from our device.

A Study on the Evaluation of Soil Nonlinear Characteristics by Seismic Recorded Data at Downhole Array (Downhole 지진계측자료에 의한 지반의 비선형성 평가에 관한 연구)

  • 장정범;서용표;이종림;이계희
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.29-35
    • /
    • 2001
  • The soil-structure interaction(SSI) analysis is essential to soil site where shear wave velocity is less than 1,050 m/sec and soil nonlinear characteristics for this kind of soil site have to be considered in SSI analysis. In order to consider soil nonlinear characteristics in the SSI analysis, simple and reliable soil nonlinear evaluation technique with seismic recorded data at downhole array is proposed in this study. The SSI analysis is carried out in order to prove the reliability of the proposed evaluation technique with Hualien large scale seismic test(HLSST) site in Taiwan. The analytical result are compared with Hualien earthquake recorded data and the analytical results with SHAKE program which is prevailed at present. As a result, the proposed evaluation technique shows a good agreement with both the Hualien earthquake recorded data and the analytical result with SHAKE program and the reliability and usefulness are confirmed.

  • PDF

Smart Passive System Based on MR Damper (MR댐퍼 기반의 스마트 수동제어 시스템)

  • Cho, Sang-Won;Jo, Ji-Seong;Kim, Chun-Ho;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.51-59
    • /
    • 2005
  • Magnetorheological(MR) dampers are one of the most promising semi active control devices, because they have advantages such as small power requirement, reliability, and low price to manufacture. To reduce the responses of structures with MR dampers, a control system including power supply, controller, and sensors is required. However, when a mount of MR dampers are used to a large?scale civil structure such as cable stayed bridges, the control system becomes complex. Therefore, it is not easy to install and maintain the MR damper based control system. To resolve above difficulties, This paper proposes a smart passive system that consists of a MR damper and an electromagnetic induction(EMI) system. According to the Faraday’s law of induction, EMI system that is attached to the MR damper produces electric energy. The produced energy is supplied to the MR damper. Thus, the MR damper with EMI system does not require any power at all. Furthermore, the induced electric energy is proportional to external loads like earthquakes, which means the MR damper with EMI system is adaptable to external loads without any controller and corresponding sensors. Therefore, it is easy to build up and maintain the proposed smart passive system.

The Study on the Monitoring of Temperature and Humidity in Public Utilization Facilities (다중 이용 시설에 대한 온.습도 모니터링에 관한 연구)

  • Choi, Man-Yong;Chae, Kyung-Hee;Kim, Ki-Bok;Kim, Su-Un
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1470-1475
    • /
    • 2009
  • Until now for the safety of structures and equipment monitoring technology to measure the amount of the physical, if that is the one, one-point or single-source target is one the most. Therefore, becoming more numerous and complex to measure the amount of physical measurement technology that is comprehensive and complex, multi-source concepts to the monitoring of a multi-sensing technology is required. Have the same characteristics of multi-source multi-use space such as a multi-structure of facilities/equipment is. The people's safety in a multi-use facility will be directly related to life and even a little carelessness can lead to large-scale disaster occurs because of several factors, risks and to manage detect in advance the development of an intelligent monitoring technology is essential. Therefore, this study shows that multiple structures/facilities to improve the quality of human life in research to maintain a safe and comfortable living space for multi-source intelligence to the development of monitoring technology to achieve that goal, and the ubiquitous sensor network system on the basis of the wireless transmission module, and multiple research facilities/equipment for the ultra-small sensors for health monitoring study was performed.

  • PDF

The Scattering Property of EVA/SiO2 Composite Film Formed Micro-aggregation Structure for Roll-to-roll Process (Roll-to-roll 적용 가능한 마이크로 응집 구조를 갖는 EVA/SiO2 복합 필름의 산란 특성)

  • Jo, Kuk Hyun;Yang, Jun Yeong;Lee, Si Woo;Park, Eun Kyoung;Choi, Geun Seok;Song, Ki Won;Kim, Hyo Jung
    • Textile Coloration and Finishing
    • /
    • v.30 no.3
    • /
    • pp.190-198
    • /
    • 2018
  • We fabricated high transmission and high scattering poly(ethylene-co-vinyl acetate)(EVA) films embedding $SiO_2$ nanoparticles to improve outcoupling efficiency in organic display. The 800nm diameter $SiO_2$ nanoparticles aggregated and formed $1.56{\mu}m$ (with ${\pm}0.853{\mu}m$ standard deviation) diameter microparticles in EVA. The total transmission of scattering film was 83.3% on Polyethylene terephthalate(PET), which was higher than reference 82.8% PET substrate. The diffuse transmission and haze of the $SiO_2$ embedded EVA film were 76.1% and 91.4%, respectively. The optimized condition was 1:1 weight ratio of $SiO_2$ nanoparticles to EVA in Tetrahydrofuran(THF) solution. When the ratio of $SiO_2$ was larger than 1, the total transmission decreased by the increase in backscattering of light due to high scattering. With the optimized condition, we could succeed to fabricate a large scale film(35m in length) with a roll-to-roll process.