• 제목/요약/키워드: large source

Search Result 2,518, Processing Time 0.032 seconds

Watershed Modeling Application for Receiving Water Quality Management in Nakdong River Basin (낙동강 유역의 수질관리를 위한 유역모델링 적용 연구)

  • Jang, Jae-Ho;Ahn, Jong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.409-417
    • /
    • 2012
  • SWAT model was applied for the Nakdong River Basin to characterize water quality variability and assess the feasibility of using the load duration curve to water quality management. The basin was divided into 67 sub-basins considering various watershed environment, and rainfall runoff and pollutant loading were simulated based on 6 year measurements of meteo-hydrological data, discharge data of treatment plants, and water quality data (SS, T-N and T-P). The results demonstrate that non-point source loads during wet season increase by 80 ~ 95% of total loads. Although the rate of water flow governs the amount of SS that is transported to the main streams, nutrient concentrations are highly elevated during dry season by being concentrated. This phenomenon is more pronounced in the lower basin, receiving large amounts of urban point source discharges such as treated sewages. Also, the load duration curves (LDC) demonstrate dominant source problems based on the load exceedances, showing that SS concentrations are associated with the rainy season and nutrients, such as T-P, may be more concentrated at low flow and more diluted at higher flow. Overall, the LDC method could be used conveniently to assess watershed characteristics and pollutant loads in watershed scale.

Congestion Aware Fast Link Failure Recovery of SDN Network Based on Source Routing

  • Huang, Liaoruo;Shen, Qingguo;Shao, Wenjuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5200-5222
    • /
    • 2017
  • The separation of control plane and data plane in Software Defined Network (SDN) makes it flexible to control the network behavior, while also causes some inconveniences to the link failure recovery due to the delay between fail point and the controller. To avoid delay and packet loss, pre-defined backup paths are used to reroute the disrupted flows when failure occurs. However, it may introduce large overhead to build and maintain these backup paths and is hard to dynamically construct backup paths according to the network status so as to avoid congestion during rerouting process. In order to realize congestion aware fast link failure recovery, this paper proposes a novel method which installs multi backup paths for every link via source routing and per-hop-tags and spread flows into different paths at fail point to avoid congestion. We carry out experiments and simulations to evaluate the performance of the method and the results demonstrate that our method can achieve congestion aware fast link failure recovery in SDN with a very low overhead.

A Study on Processing of TFT Electrodes for Digital Signage Display using a Reverse Offset Printing (리버스옵셋 프린팅을 이용한 디지털 사이니지 디스플레이용 TFT 전극 형성 공정 연구)

  • Yoon, Sun Hong;Lee, Junsang;Lee, Seung Hyun;Lee, Bum-Joo;Shin, Jin-Koog
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.6
    • /
    • pp.497-504
    • /
    • 2014
  • The digital signage display is actively researched as the next generation of large FPD. To commercialize those digital signage display, the manufacturing cost must be downed with printing method instead of conventional photolithography. Here, we demonstrate a reverse offset printed TFT electrodes for the digital signage display. For the fabricated source/drain and gate electrode, we used Ag ink, silicone blanket, Clich$\acute{e}$ and reverse offset printer. We printed uniform TFT electrode patterns with narrow line width(10 ${\mu}m$ range) and thin thickness(nm range). In the end the printing source/drain and gate electrode are successfully achieved by optimization of experimental conditions such as Clich$\acute{e}$ surface treatment, ink coating process, delay time, off/set process and curing temperature. Also, we checked that the printing align accuracy was within 5 ${\mu}m$.

STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS

  • El-Khatib, Ahmed M.;Thabet, Abouzeid A.;Elzaher, Mohamed A.;Badawi, Mohamed S.;Salem, Bohaysa A.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • The present work used the efficiency transfer method used to calculate the full energy peak efficiency (FEPE) curves of the (2"*2" & 3"*3") NaI (Tl) detectors based on the effective solid angle subtended between the source and the detector. The study covered the effect of the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius) on the detector efficiency. $^{152}$ An Eu aqueous radioactive source covering the energy range from 121.78 keV up to 1408.01 keV was used. In this study an empirical formula was deduced to calculate the difference between the measured and the calculated efficiencies [without self attenuation] at low and high energy regions. A proper balance between the measured and calculated efficiencies [with self attenuation] was achieved with discrepancies less than 3%, while reaching 39% for calculating values [without self attenuation] due to working with large sources, or for low photon energies.

Localization of Underwater Noise Sources Using TDOA (Time Difference of Arrival) Method (도달지연시간 기법을 이용한 수중 소음원의 위치추적)

  • Ahn, Byoung-Kwon;Go, Yeong-Ju;Rhee, Wook;Choi, Jong-Soo;Lee, Chang-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • As considerable interests in noise emission from a ship have been increased, the need for localization of noise sources of the marine propeller generating cavitation and singing noise is looming large. In many practical cases, cavitation and singing noise occur on a particular position of the certain blade of the propeller. It is so important to know the position of noise source correctly in order to eliminate or suppress unwanted noise. In this study, we develop "noise source localization technology" using TDOA method. Experimental measurements carried out at the circulating water channel and towing tank show that noise source can be clearly identified and localized using TDOA method.

Enhanced Biodegradation of 2,4,6-Trinitrotoluene (TNT) with Various Supplemental Energy Sources

  • Park, Chulhwan;Kim, Tak-Hyun;Kim, Sangyong;Kim, Seung-Wook;Lee, Jinwon
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.4
    • /
    • pp.695-698
    • /
    • 2002
  • The biodegradation of 2,4,6-trinitrotoluene (TNT) was performed on a laboratory scale using P. putida originally isolated from explosive-contaminated soil. One hundred mg/1 of TNT was completely degraded within 20 h under optimum conditions. Various supplemental energy sources (carbon sources, nitrogen sources, and surfactant) were tested, with the main objective of identifying an inexpensive source and enhancing the degradation rate for large-scale biodegradation. Based on the degradation rate, molasses was selected as a possible supplemental carbon source, along with NH$_4$Cl and Tween 80 as a nitrogen source and surfactant, respectively. The degradation rate increased about 3.3 fo1d when supplemental energy sources were added and the degradation rate constant increased from 0.068 h$\^$-1/ to 0.224 h$\^$-1/. These results appear to be promising in application of the process to TNT-contaminated soil applications.

Performance of Air Source Heat Pump with a Fiber Belt Heat Regeneration System (섬유벨트 열재생 시스템을 부착한 공기 열원 열펌프의 난방 성능 특성)

  • 유영선;장진택;김영중;강금춘;윤진하;이건중
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.385-390
    • /
    • 2000
  • The heat pump is one of heating and cooling systems driven by electricity using natural energy as a heat source. The heat pump system was mainly adopted to a cooling system or a refrigeration system. In regions with a large amount of electricity, it is used as a heating system or a heating and cooling system of houses, buildings and agricultural facilities. During cold weather, air source heat pumps do not work well because of some technical problems, such as frosting on evaporator coil when outside air temperature is below -5$^{\circ}C$. In this research, the heat regenerative technology was employed to eliminate the frosting on evaporator coil and improve the COP of the heat pump system. This fiber belt heat regeneration system(FBHRS) has very simple structure consisting of a geared motor and a porous fiber belt passing through alternatively between cold and warm air duct. The laboratory test showed that the heat pump system with a FBHRS yielded an impressive COP higher than 3.5 at the outside air temperature of -7$^{\circ}C$ in heating mode.

  • PDF

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.

A Study on Developing the Simulation Model of Micro-Sources (마이크로소스의 EMTDC 시뮬레이션 모델 개발에 관한 연구)

  • Son, Kwang-Myoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.24-32
    • /
    • 2005
  • Micro-source units having power ratings in thousands of watts can provide power quality with higher reliability and efficiency than the conventional large scale units. Since these units are small and easy to install, they are clustered with loads creating micro-grid services to customer sites such as office buildings, industrial parks and homes. Micro-sources adopt voltage source inverter to ensure the power quality of sensitive loads. This paper deals with the connection of micro-sources into the system grid EMTDC modeling of the grid connected micro-sources at the power frequency range are proposed and the characteristics of the control system parameters are investigated. Simulation results show that the micro-grid system with two micro-sources has good dynamic characteristics.

The Fabrication and Characteristics of White Emission Using CCM on Flexible Substrate (플렉시블 무기EL 색변환 백색 발광 소자 제작 및 특성평가)

  • Kim, Gi-Ryoung;Ahn, Sung-Il;Kum, Jeong-Hun;Lee, Heung-Ryeol;Yim, Tae-Hong;Lee, Seong-Eui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.411-412
    • /
    • 2007
  • EL (electro luminescent) is generally studied as a large size plane light emitting device and flexible light source because of it's simple manufacturing process. In this experiment, we manufactured flexible white emitting light source using Ni-foil with blue phosphor and color change materials. With increasing the thickness of color change material, the luminance of white emission is increased and the color coordinate of white color was shifted to pure white of (0.317,0.328) by strong emission of color change materials excited by blue excitation spectra. Also the luminance level was 30% higher in white emitting light device than blue only light source.

  • PDF