• 제목/요약/키워드: large scale calorimeter

검색결과 25건 처리시간 0.027초

SiO2 캡슐화 파라핀 상변화 물질의 상전이 역학에 대한 캡슐화 비율의 영향 (Effect of Encapsulation Ratio on the Phase Transition Kinetics of the SiO2 Encapsulated Paraffin Phase Change Materials)

  • 소우멘 만달;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2023
  • In this study, an approach has been made to understand the effect of encapsulation thickness of the nanoencapsulated PCMs on the phase transition kinetics. Paraffin is encapsulated by silica via single pot polycondensation reaction. Different ratios of silica precursor are chosen to encapsulate paraffin. The obtained encapsulated PCMs are identified as nano sized, as well as with increasing silica precursor, thicker silica encapsulations have been manifested with shrinking core diameter. The synthesized PCMs are characterized using various characterization techniques. Isochronal kinetic studies are done in differential scanning calorimeter (DSC) to understand about their phase transformation behaviors. This study can appreciate the cognition of the large-scale applications of PCMs into the building constructions as well as the fundamental conception on the phase transition kinetics of PCMs can also be amended.

  • PDF

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

룸 코너 콘 칼로리미터 시험(ISO 9705)과 비교를 통한 FDS 열분해 모델의 신뢰성 분석 (A Reliability Analysis on FDS Pyrolysis Model through Comparing the Room-Corner (ISO 9705) Test)

  • 양성진;이창덕;오지은;강찬용;김학범;이덕희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.585-593
    • /
    • 2011
  • Actual fire test under a laboratory and fire simulation by using computer are considered into main methodology in order to estimate and predict fire size of railway train. Even if practical fire size could be obtained from the full-model railway car test such as a large scale cone-calorimeter test, it is not always possible and realistic due to that expensive cost and attendant dangers could in no way be negligible. In this point of view, fire simulation analysis method based on the computational fluid dynamics could be proposed as an alternative and it seems to be also efficient and reasonable. However, simulation results have to be verified and validated in accordance with the proper procedure including comparing analysis with the actual fire test. In this paper, fire load and growth aspect was investigated through the room corner test (ISO 9705) for the mock-up model of the actual railway car. Then, it was compared with the output data derived from the simulation by using Pyrolysis Model of the FDS (Fire Dynamics Simulator, by NIST) for the exact same domain and condition corresponding with pre-performed room-corner test. This preliminary verified and validated fire modeling method could enhance the reliability of output data derived from the fire simulation under the similar domain and condition.

  • PDF

가구류에 대한 화재 특성 연구 (The Study on Fire Characteristics of Furniture)

  • 권오상;유용호;김흥열;임영수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.379-384
    • /
    • 2009
  • 본 연구에서는 다세대 주택에서 발생되는 화재에서 가연물질이 되는 가구류에 대한 화재 특성을 파악하기 위해 단위 가연물에 대한 열방출율(HRR, Heat Release Rate), 연기발생량, 유독가스 발생량 등에 대한 기본 DB를 확보하고자 하였다. 실험에 사용된 단위가연 물에는 침대(매트리스 포함), 장롱, 화장대, 책상, 책장, 소파(3+1인용), TV, 싱크대(찬장포함), 냉장고, 이불(옷가지)등 총 12여종이며, 국제 시험 규격인 ISO 9705 시험법인 중규모 시험 장치(Room Corner Tester)와 10MW 급의 실규모화재실험장치(Large Scale Calorimeter)에서 실험을 진행하였다. 실험결과 냉장고에서 가장 높은 최대 열방출율 약 3051 kW, 장롱에서의 일산화탄소 방출량은 최대 약 3894.2 ppm, 이산화탄소의 방출량은 최대 약 1.8% 로 가장 높게 측정되었다. 이러한 중규모 시험 장치를 통한 단위 품목의 화재특성 DB 작성은 단위구획에서의 화재 확산 예측에 가장 중요한 요소가 될 수 있을 것이다.

  • PDF

3D 프린팅용 경량재료 혼입 폴리머 시멘트 모르타르의 난연특성 (Flame Retardant Properties of Polymer Cement Mortar Mixed with Light-weight Materials for 3D Printing)

  • 손배근;송훈
    • 한국건설순환자원학회논문집
    • /
    • 제9권3호
    • /
    • pp.330-337
    • /
    • 2021
  • 3D 프린팅의 기술발전으로 대형물 제작이 가능하게 되면서 이를 건축물에 적용하기 위한 연구가 활발하게 진행되고 있다. 건축물에서는 구조재와 비구조재로 구분되고 비구조재는 비정형 구조물 및 내·외장패널에 적용하기 유리하다. 3D 프린팅 재료는 기본적으로 시멘트 모르타르의 압출과 적층이 가능해야하므로 시멘트 혼화용 폴리머 와 경량재료의 사용이 필수적이다. 본 연구는 3D 프린팅 적용을 위해 시멘트 모르타르에 EVA 재유화형 분말수지를 사용하였다. 경량재료 혼입 폴리머 시멘트 모르타르의 난연특성을 평가하기 위해 골재로는 규사8호와 경량재료로 경량골재, 중공글라스를 사용하여 난연 및 불연성능을 평가하였다. 연구결과, 규사8호 및 경량골재를 사용한 시험체가 충분한 난연 및 불연성능을 보였다. EVA 재유화형 분말수지를 혼입할 경우 5% 이하로 적용하여 사용하는 것이 유리하다.