• Title/Summary/Keyword: large electric field

Search Result 377, Processing Time 0.027 seconds

Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF) (근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가)

  • Park, Kyoung-Ho;Ahn, Yong-Ho;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

Hand Motion Signal Extraction Based on Electric Field Sensors Using PLN Spectrum Analysis (PLN 성분 분석을 통한 전기장센서 기반 손동작신호 추출)

  • Jeong, Seonil;Kim, Youngchul
    • Smart Media Journal
    • /
    • v.9 no.4
    • /
    • pp.97-101
    • /
    • 2020
  • Using passive electric field sensor which operates in non-contact mode, we can measure the electric potential induced from the change of electric charges on a sensor caused by the movement of human body or hands. In this study, we propose a new method, which utilizes PLN induced to the sensor around the moving object, to detect one's hand movement and extract gesture frames from the detected signals. Signals from the EPS sensors include a large amount of power line noise usually existing in the places such as rooms or buildings. Using the fact that the PLN is shielded in part by human access to the sensor, signals caused by motion or hand movement are detected. PLN consists mainly of signals with frequency of 60 Hz and its harmonics. In our proposed method, signals only 120 Hz component in frequency domain are chosen selectively and exclusively utilized for detection of hand movement. We use FFT to measure a spectral-separated frequency signal. The signals obtained from sensors in this way are continued to be compared with the threshold preset in advance. Once motion signals are detected passing throng the threshold, we determine the motion frame based on period between the first threshold passing time and the last one. The motion detection rate of our proposed method was about 90% while the correct frame extraction rate was about 85%. The method like our method, which use PLN signal in order to extract useful data about motion movement from non-contact mode EPS sensors, has been rarely reported or published in recent. This research results can be expected to be useful especially in circumstance of having surrounding PLN.

Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss (자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가)

  • Lee, S.;Park, S.H.;Kim, W.S.;Lee, J.K.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.

Calculation of Magnetic Fields under 3 Phase Power Lines with Branch Lines (분기선로가 있는 3상 전력선로하의 전자파 자계 계산)

  • Kang, Dae-Ho;Lee, Yong-Sik;Kim, Bu-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.110-119
    • /
    • 2009
  • In this study magnetic fields near electric power lines with branch lines which have a arbitrary angle were derived and formulated by dipole antenna theory and could be calculated easily using the formula. It seems that those formula could be applicable to the consideration of magnetic fields during the design of distribution lines with branch lines. As an example those formulated equations on elements of magnetic fields were applied to a model of 3 phase distribution lines with branch lines and calculated by Matlab programs and the results were presented The analyzed results are follows. The resultant magnetic field is dominated by the componant By all over y-axis in the case of the smaller branched angle $\alpha$ and the lower observed point z. In case of ${\alpha}=\frac{\pi}{2}$[rad], the resultant field is affected by the componant Bx. The resultant field is dominated by the componant Bz at the vicinity of the power lines and it shows very large value at the branch line position of y-axis in case of ${\alpha}>\frac{\pi}{2}$.

A Basic Study on the Estimation of Discharge Current Waveform and the Insulation Diagnosis by the Measurement of Electromagnetic Environment (전자환경 측정에 의한 방전전류 파형추정과 절연진단의 기초 연구)

  • Park, Gwang-Seo;Kim, Gi-Chae;Kim, Lee-Guk;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.492-499
    • /
    • 2002
  • This paper presents the method for an estimation of discharge current waveform in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation is to use the one antenna method (single field method) with a measured electric or magnetic field at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveform estimation was performed by one antenna methods using the measured electric fields of Wilson & Ma and compared with experiments. In addition diagnosis technique for power equipments is able to prevent from large accidents by finding signs of tile accidents before they happen. From the results of the estimation of discharge current, we have a possibility for the application of insulation diagnosis technique for power equipments using S$F_6$ gas. From this point of view, this paper simulated discharge progress and partial discharge by using needle-plan electrodes system in S$F_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using a biconical antenna and a spectrum analyzer. From the experimental results of this study, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting Partial discharge and estimating discharge progress in S$F_6$ could be Possible.

TEC VARIATIONS OVER KOREAN PENINSULA DURING MAGNETIC STORM (남쪽방향 행성간 자기장에 의해 발생한 자기 폭풍 동안 한반도 상공의 총 전자수 함유량 변화)

  • Ji, E.Y.;Choi, B.K.;Kim, K.H.;Lee, D.H.;Cho, J.H.;Chung, J.K.;Park, J.U.
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.1
    • /
    • pp.33-42
    • /
    • 2008
  • By analyzing the observations from a number of ground- and space-based instruments, including ionosonde, magnetometers, and ACE interplanetary data, we examine the response of the ionospheric TEC over Korea during 2003 magnetic storms. We found that the variation of vertical TEC is correlated with the southward turning of the interplanetary magnetic field $B_z$. It is suggested that the electric fields produced by the dynamo process in the high-latitude region and the prompt penetration in the low- latitude region are responsible for TEC increases. During the June 16 event, dayside TEC values increase more than 15%. And the ionospheric F2-layer peak height (hmF2) was ${\sim}300km$ higher and the vertical $E{\times}B$ drift (estimated from ground-based magnetometer equatorial electrojet delta H) showed downward drift, which may be due to the ionospheric disturbance dynamo electric field produced by the large amount of energy dissipation into high-latitude regions. In contrast, during November 20 event, the nightside TEC increases may be due to the prompt penetration westward electric field. The ionospheric F2-layer peak height was below 200km and the vertical $E{\times}B$ drift showed downward drift. Also, a strong correlation is observed between enhanced vertical TEC and enhaaced interplanetary electric field. It is shown that, even though TEC increases are caused by the different processes, the electric field disturbances in the ionosphere play an important role in the variation of TEC over Korea.

An Analysis of Particle-clumping Phenomena of a Charged Particle-type Reflective Electronic Display

  • Kim, Young-Cho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.212-214
    • /
    • 2012
  • Both the electrically positive and negative particles in a cell of quick response-liquid powder display (QR-LPD) are surrounded by conductive electrodes on the upper and lower substrate and the dielectric materials of the barrier ribs. Particles in a cell are attached to or detached from the other materials by image force, electric field, Coulomb's force, and Van der Waals' force. Through these forces, the moving particles form an image but induce clumping phenomena. Particles having a large kinetic energy by a large q/m value crash into the opposite electrode with high speed at a large driving voltage and quickly lose electrically charged material. As a result, these particles are clumped and degrade panel performance. The clumped particles in a cell are observed by microscopic photographs and ascertained by a response time. When the bias voltage is increased to 0.68-0.76 $V/{\mu}m$, particle clumping occurs abruptly and the response time increases sharply. This particle clumping is similarly observed after the number of driving times at the driving voltage (0.42-0.64 $V/{\mu}m$).

TFT production and electric characteristic comparison by ELA and MICC technique (ELA 및 MICC 기법을 이용한 TFT의 제작 및 전기적 특성 비교)

  • Park, Tae-Ung;Lee, Won-Back;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.146-146
    • /
    • 2010
  • Electrical properties of Large-grain-size TIT with 7/7 ${\mu}m$ channel width and length which gate insulator is made of 20nm $SiO_2$ and 80nm $SiN_x$. was fabricated and measured with Large-grain-size technic(MICC) and compared to ELA technic's data. The field-effect mobility was decreased from 106.78 to $88.74\;cm^2$/Vs and threshold voltage also decreased from -1.8382 to -0.9529 V, when TFT process is changed from ELA technic to MICC technic. Subthreshold swing, also, increased from 0.22 to 0.32 V/dec and $I_{on/off}$ ratio decreased from $1.12{\times}10^8$ to $5.75{\times}10^7$.

  • PDF

Printing of Polymer Dielectric via Optimal Blade Coating for Large-scale Low-Leakage Capacitors (대면적 저누설 커패시터를 위한 최적화 블레이드 코팅 기반 고분자 유전체 프린팅)

  • Seo, Kyeong-Ho;Bae, Jin-Hyuk
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.51-55
    • /
    • 2021
  • We demonstrated a polymer dielectric with low leakage characteristics through an optimal blade coating method for low-cost and large-scale fabrication of metal-insulator-metal (MIM) capacitors. Cross-linked poly(4-vinylphenol) (C-PVP), which is a typically used polymer dielectric, was coated on a 10 × 10 cm indium-tin-oxide (ITO) deposited glass substrate by changing the deposition temperature (TD) and coating velocity (VC) in the blade coating. During the blade coating, the thickness of the thin c-PVP varied depending on TD and VC owing to the 'Landau-Levich (LL) regime'. The c-PVP-dielectric-based MIM capacitor fabricated in this study showed the lowest leakage current characteristics (10-6 A/㎠ at 1.2 MV/㎠, annealing at 200 ℃) and uniform electrical characteristics when TD was 30 ℃ and VC was 5 mm/s. In addition, at TD = 30 ℃, stable leakage characteristics were confirmed when a different electric field was applied. These results are expected to positively contribute to applications with next-generation electronic devices.

Analysis on the Dielectric Characteristics of Various Insulation Gases for Developing a Sub-cooled Liquid Nitrogen Cooling System (과냉질소 냉각시스템 가압용 기체의 절연내력특성 분석)

  • Kang, H.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.27-30
    • /
    • 2011
  • A sub-cooled liquid nitrogen cooling system is known as a most promising method to develop large scale superconducting apparatuses such as superconducting fault current limiters and superconducting cables [1]. Gaseous helium (GHe), gaseous nitrogen ($GN_2$) and sulfur hexafluoride ($SF_6$) are commonly used for designing an high voltage applied superconducting device as an injection gaseous medium [2, 3]. In this paper, the analysis on the dielectric characteristics of GHe, $GN_2$ and $SF_6$ are conducted by designing and manufacturing sphere-to-plane electrode systems. The AC withstand voltage experiments on the various gaseous insulation media are carried out and the results are analyzed by using finite element method (FEM) considering field utilization factors (${\xi}$). It is found that the electric field intensity at sparkover ($E_{MAX}$) of insulation media exponentially decreases according to ${\xi}$ increases. Also, the empirical expressions of the functional relations between $E_{MAX}$ and ${\xi}$ of insulation media are deduced by dielectric experiments and computational analyses. It is expected that the electrical insulation design of applied superconducting devices could be performed by using the deduced empirical formulae without dielectric experiments.