Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector (형광체 스크린 기반 평판형 X선 검출기 적용을 위한 요오드화수은 필름 광도전체 센서 설계 및 제작)

  • Park, Ji Koon;Jung, Bong Jae;Choi, Il Hong;Noh, Si Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.189-194
    • /
    • 2014
  • In this study, from a new x-ray detector that combines a columnar CsI:Na scintillation layer with a photosensitive mercuric iodide layer was investigated. In this structure, X-rays are converted into visible light on a thick CsI:Na layer, which is then converted to electric charges in a thin $HgI_2$ bottom layer. The thin coplanar mercuric iodide films as a photosensitive converter requiring only a few tens of volts of bias, associated with a thick columnar coating of phosphor layer, were simulated and designed. The results of this research suggest that the new coplanar x-ray detector with a hybrid-type structure can resolve the following problems: high voltage from the a-Se, and low conversion efficiency from the indirect conversion method. The results of this research suggest that the new CsI:Na/$HgI_2$ x-ray detector with a double-layer type structure can resolve the following problems: high voltage from the direct conversion method, and low conversion efficiency from the indirect conversion method.

The characteristic study of hybrid X-ray detector using CdTe and Zns:AgCl phosphor (CdTe 와 ZnS:AgCl phosphor를 이용한 Hybrid형 X선 검출기의 특성연구)

  • Seok, Dae-Woo;Kang, Sang-Sik;Kim, Jin-Young;Park, Ji-Koon;Mun, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.71-74
    • /
    • 2003
  • Photoconductor for direct detection fiat-panel imager present a great materials challenge, since their requirement include high X-ray absorption, ionization and charge collection, low leakage current and large area deposition, CdTe is practical material. We report studies of detector sensitivity, That is an CdTe with $5{\mu}m$ thickness on glass. That is hybrid layer of depositting ZnS:AgCl phosphor with $100{\mu}m$ on CdTe. The leakage current of hybrid is similar to it of a-Se, but photocurrent is larger than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

Fabrication and Characterization of Polycrystalline Mereuric Iodide Films using Particle-in-Binder Methods (Particle-in-Binder(PIB) 법을 이용한 다결정 $HgI_2$ 필름 제작 및 특성 연구)

  • Cha, Byung-Youl;Cho, Sung-Ho;Kim, So-Yeong;Woon, Min-Seuk;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.330-330
    • /
    • 2007
  • Polycrystalline mercuric iodide $HgI_2$) films are being developed as a new detector technology for digital x-ray imaging. The $HgI_2$ is generally vacuum deposited by physical vapor deposition (PVD) process. But the PVD thick deposition has been caused any instability in the biasing due to any defects or cracks. In this work we present a new particle-in-binder (PIB) methodologies used for the $HgI_2$ thick films. These growth techniques can be easily extended to produce much larger film areas. This paper, for the first time, presents results and comparison of polycrystalline $HgI_2$ films derived by various PIB methods. We investigated the structural and morphological properties of the films using X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis. The films were characterized with respect to their electrical properties and in response to x-ray photons. Physical and electrical results were also compared between conventional polycrystalline PVD and our detectors. Leakage current as low as $350\;pA/cm^2$ at the bias voltage of ~ 200 V has been observed. And high sensitivity and good linearity in the response to x-rays was obtained in the film derived by PIB sedimentation method. Our future efforts will concentrate on optimization of film growth techniques for uniform large area deposition on image readout arrays.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Study on the dark current reduction of $HgI_2$ radiation detector ($HgI_2$ 방사선 검출기의 누설전류 저감에 관한 연구)

  • Shin, Jung-Wook;Kang, Sang-Sik;Kim, Jin-Young;Kim, Kyung-Jin;Park, Sung-Kwang;Jo, Heung-Lae;Lee, Hyung-Won;Nan, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.456-459
    • /
    • 2004
  • Analog film/screen systems have been being changed to a digital x-ray imaging device using direct conversion materials. Photocoductors for a direct detection flat-panel imager require high x-ray absorption, ionization and charge collection, low leakage current and large area deposition. In this work, $HgI_2$ films with excellent properties for x-ray detector were deposited by screen printing method. The thickness of $HgI_2$ film was about $150\;{\mu}m$. The passivation layer is fabricated using a-Se and parlyene, the both fabrication $HgI_2$ film were compared for analyzing the leakage current reduction. We measured electrical properties-leakage current, photosensitivity, SNR though I-V measurement, As the result, $HgI_2$ film using a-Se passivation layer had the greater

  • PDF

Analysis of Signal Properties in accordance with electrode area of x-ray conversion material (X선 검출 물질의 전극 면적에 따른 신호특성 분석)

  • Jeon, S.P.;Kim, S.H.;CHO, K.S.;Jung, S.H.;Park, J.K.;Kang, S.S.;Han, Y.H.;Kim, K.S.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.5-9
    • /
    • 2010
  • In recent, a digital x-ray detector attracted worldwide attention and there are many studies to commercialize. There are two methods in digital x-ray detector. This method is an Indirect method and Direct method. This study is to see the differences between the digital x-ray detector based on a-Se used in the existing indirect conversion method and an x-ray conversion material that has better SNR(Signal-to-noise ratio) and property than the a-Se. To solve the problem that is difficult to make a large area film using Screen-Print method, we used a Screen-Print method. In this study, we used a polyclystal $HgI_2$ as x-ray conversion material and a sample thickness is $150{\mu}m$ and an area is $3cm{\times}3cm$. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a Magnetron Sputtering System and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$ and then we evaluated darkcurrent, sensitivity and SNR of the $HgI_2$ film are measured, then we evaluated the electrical properties. And we used a current integration mode when I-V test. This experiment shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high darkcurrent. Through fabricating of various thicknesses and optimal electrodes, we will optimize SNR in the future work.

Development of Agricultural Products Screening System through X-ray Density Analysis

  • Eunhyeok Baek;Young-Tae Kwak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.105-112
    • /
    • 2023
  • In this paper, we propose a new method for displaying colored defects by measuring the relative density with the wide-area and local densities of X-ray. The relative density of one pixel represents a relative difference from the surrounding pixels, and we also suggest a colorization of X-ray images representing these pixels as normal and defective. The traditional method mainly inspects materials such as plastics and metals, which have large differences in transmittance to the object. Our proposed method can be used to detect defects such as sprouts or holes in images obtained by an inspection machine that detects X-rays. In the experiment, the products that could not be seen with the naked eye were colored with pests or sprouts in a specific color so that they could be used in the agricultural product selection system. Products that are uniformly filled with a single ingredient inside, such as potatoes, carrots, and apples, can be detected effectively. However, it does not work well with bumpy products, such as peppers and paprika. The advantage of this method is that, unlike machine learning, it doesn't require large amounts of data. The proposed method could be applied to a screening system using X-rays and used not only in agricultural product screening systems but also in manufacturing processes such as processed food and parts manufacturing, so that it can be actively used to select defective products.

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

Development of Multi-channel Detector of X-ray Backscatter Imaging (후방산란 엑스선 영상획득을 위한 다채널 검출기 개발)

  • Lee, Jeonghee;Park, Jongwon;Choi, Yungchul;Lim, Chang Hwy;Lee, Sangheon;Park, Jaeheung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.245-247
    • /
    • 2022
  • Backscattered x-ray imaging is a technology capable of acquiring an image inside an irradiated object by measuring X-rays scattered from an object. For image acquisition, the system must include an X-ray generator and a detection system for measuring scattered x-rays. The imaging device must acquire a real-time signal at sampling intervals for x-rays generated by passing through a high-speed rotating collimator, and for this purpose, a high-speed signal acquisition device is required. We developed a high-speed multi-channel signal acquisition device for converting and transmitting signals generated by the sensor unit composed of a large-area plastic scintillator and a photomultiplier tube. The developed detector is a system capable of acquiring signals at intervals of at least 15u seconds and converting and transmitting signals of up to 6 channels. And a system includes remote control functions such as high voltage, signal gain, and low level discrimination for individual calibration of each sensor. Currently, we are conducting an application test for image acquisition under various conditions.

  • PDF

Interpretation of the Chemical Transformation of Individual Asian Dust Particles Collected on the Western Coast of Korean Peninsula

  • Ma, Chang-Jin;Kim, Jong-Ho;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 2012
  • This paper is focused on the comprehensive and detailed interpretation for the chemical transformation of individual Asian dust (hereafter called "AD") particles during long-range transport from source regions to receptor area. A multi-stage particle sampler was operated at a ground-based site in Taean, Korea directly exposed to the outflow of air masses from China during AD period in April 2003. Both quantitative and qualitative analyses for size-classified individual particles were carried out by a microbeam X-ray fluorescence (XRF) method and a microbeam Particle Induced X-ray Emission (micro-PIXE), respectively. Among major characteristic elements, the elemental masses of soil derived components, sulfur, and chloride varied as a function of particle size showing the monomodal maximum with a steeply increasing at 3.3-4.7 ${\mu}m$ particle size. Although the details on chemical composition of AD particle collected on a straight line from source area to our ground-based site are needed, a large amount of Cl coexisted in and/or on AD particles suggests that AD particles collected in the present study might be actively engaged in chemical transformation by sea-salt and other Cl containing pollutants emitted from the China's domestic sources. Through the statistical analyses it was possible to classify individual AD particles into six distinct groups. The internally mixed AD particles with Cl, which has various sources (e.g., sea-salt, coal combustion origin HCl, gaseous HCl derived from the adsorption of acids to sea-salt, and Cl containing man-made particles) were thoroughly fractionated by the elemental spectra drivened by the double detector system of micro-PIXE.