• 제목/요약/키워드: large area

검색결과 8,123건 처리시간 0.04초

대면적 레이저 가공을 위한 가감속 파라미터가 가공오차에 미치는 영향 (Effects of Acceleration and Deceleration Parameters on the Machining Error for Large Area Laser Processing)

  • 이제훈;윤광호;김경한
    • 한국정밀공학회지
    • /
    • 제31권8호
    • /
    • pp.721-728
    • /
    • 2014
  • In this paper, it is proposed a method of optimizing path parameters for large-area laser processing. On-the-fly system is necessary for large-area laser processing of uniform quality. It is developed a MOTF(Marking On-The-Fly) board for synchronizing the stage and scanner. And it is introduced the change of the error due to the change of parameters and algorithm for large-area laser processing. This algorithm automatically generates stage path and a velocity profile using acceleration and deceleration parameters. Since this method doesn't use a G-code, even if without expert knowledge, it has an advantage that can be accessed easily. Angle of one of the square of $350{\times}350mm$ was changed from $50^{\circ}$ to $80^{\circ}$ and analyzed the error corresponding to the value of Ta. It is calculated the value of Ta of the best with a precision of 20um through measurement of accuracy according to the Ta of each angle near the edge.

대면적 박막 태양전지 적용을 위한 CdTe 박막의 화학적기계적연마 공정 특성 (Chemical Mechanical Polishing Characteristics of CdTe Thin Films for Application to Large-area Thin Film Solar Cell)

  • 양정태;신상헌;이우선
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1146-1150
    • /
    • 2009
  • Cadmium telluride (CdTe) is one of the most attractive photovoltaic materials due to its low cost, high efficiency and stable performance in physical, optical and electronic properties. Few researches on the influences of uniform surface on the photovoltaic characteristics in large-area CdTe solar cell were not reported. As the preceding study of the effects of thickness-uniformity on the photovoltaic characteristics for the large-area CdTe thin film solar cell, chemical mechanical polishing (CMP) process was investigated for an enhancement of thickness-uniformity. Removal rate of CdTe thin film was 3160 nm/min of the maximum value at the 200 $gf/cm^2$ of down force (pressure) and 60 rpm of table speed (velocity). The removal rate of CdTe thin film was more affected by the down force than the table speed which is the two main factors directly influencing on the removal rate in CMP process. RMS roughness and peak-to-valley roughness of CdTe thin film after CMP process were improved to 96.68% and 85.55%, respectively. The optimum process condition was estimated by 100 $gf/cm^2$ of down force and 60 rpm of table speed with the consideration of good removal uniformity about 5.0% as well as excellent surface roughness for the large-area CdTe solar cell.

Producing Uniform High Illumination Large Area Backlight Systems with Long Life

  • Guzowski, Lawrence T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.779-782
    • /
    • 2004
  • Establishing and maintaining optimum lamp operating temperature is critically important in backlight systems for large area displays. The information presented in this paper is based upon work completed for a tiled 37.5" AM LCD, plus projections for a 37.5", 42" & 50" monolithic display. Due to the size of the units, a requirement for highly collimated light and a requirement for high brightness, >550 nits at the display surface, significant wattage is required which generates high heat levels in the backlight display assembly and potentially, at the display rear surface. Uniformity of illumination becomes an important element in the system design because of the large area involved.

  • PDF

Combining Hough Transform and Fuzzy Unsupervised Learning Strategy in Automatic Segmentation of Large Bowel Obstruction Area from Erect Abdominal Radiographs

  • Kwang Baek Kim;Doo Heon Song;Hyun Jun Park
    • Journal of information and communication convergence engineering
    • /
    • 제21권4호
    • /
    • pp.322-328
    • /
    • 2023
  • The number of senior citizens with large bowel obstruction is steadily growing in Korea. Plain radiography was used to examine the severity and treatment of this phenomenon. To avoid examiner subjectivity in radiography readings, we propose an automatic segmentation method to identify fluid-filled areas indicative of large bowel obstruction. Our proposed method applies the Hough transform to locate suspicious areas successfully and applies the possibilistic fuzzy c-means unsupervised learning algorithm to form the target area in a noisy environment. In an experiment with 104 real-world large-bowel obstruction radiographs, the proposed method successfully identified all suspicious areas in 73 of 104 input images and partially identified the target area in another 21 images. Additionally, the proposed method shows a true-positive rate of over 91% and false-positive rate of less than 3% for pixel-level area formation. These performance evaluation statistics are significantly better than those of the possibilistic c-means and fuzzy c-means-based strategies; thus, this hybrid strategy of automatic segmentation of large bowel suspicious areas is successful and might be feasible for real-world use.

APPLICATION OF SATELLITE IMAGERY FOR DROUGHTS MONITORING IN LARGE AREA

  • Shin Sha-Chul;Jeong Soo;Kim Kyung-Tak;Kim Joo-Hun;Park Jung-Sool
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.398-401
    • /
    • 2005
  • Droughts have been an important factor in disaster management in Korea because she has been grouped into nations of lack of water. Satellite imagery can be applied to droughts monitoring because it can afford periodic data for large area for long time. This study aims to develop a method to analyze droughts in large area using satellite imagery. We estimated evapotranspiration in large area using NDVI data acquired from satellite imagery. For satellite imagery, we dealt with MODIS data operated by NASA. As the result of this study, we improved the usability of satellite imagery, especially in drought analysis.

  • PDF

마이크로 전자칼럼을 이용한 대면적 스캔 (Scanning large area with a micro-electron column)

  • 장원권;박성순;김호섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.182-183
    • /
    • 2007
  • In large area scanning with a micro-electron column, the optimal operation condition for the best visibility was studied. A micro-electron column can realize nearly unlimited scanning size with distribution of micro-electron columns, therefore applicable to large sized SEM or VSEM. The maximum scanning size with a micro-electron column was about $200cm^2$ when only one deflector was employed. However, a double deflector equipped micro-electron column provided 1.7 times larger scanning area with the same visibility as that of one deflector.

  • PDF

MODFLOW를 이용한 도심지역 대형 건축물 신축에 따른 지하수 흐름 및 지하수위 변화예측에 관한 연구 (Simulation of Flow Change and Level of Groundwater using MODFLOW Due to Large-size Building Construction in Metropolitan Area)

  • 박선환;장윤영;임형규
    • 환경영향평가
    • /
    • 제16권4호
    • /
    • pp.251-265
    • /
    • 2007
  • In this study, the influence of the construction of a large sized building on the flow and level of groundwater in a metropolitan area was investigated with simulation model MODFLOW for a selected area located in Gangseo-gu, Seoul, where a large business center was scheduled to be built. It was simulated that the groundwater level in the study area was suddenly lowered by the construction of a large building and groundwater in the surrounding area fast flowed into the study area. And even after the construction finished, the falling down of groundwater level consistently continued in some degree. The flow state of groundwater appeared to be the same in both cases where a soil cement wall is applied and where it is not during the construction. But for the case of application of a soil cement wall as the amount of groundwater flowing into the study site became reduced, it was estimated that the time for underground watershed getting far away from the site was also reduced and the influence of a building construction on the surrounding groundwater became reduced. Thus, it is deemed necessary that recharging the spilled ground water and rainfall into the construction area to lessen the abrupt change in flow and level of ground water should be considered in design of construction of a large sized building in a metropolitan area.

대면적 세라믹 연료전지용 단전지 제조 및 특성 연구 (Fabrication and Characteristics of Ceramic Fuel Cell with a Large Electrode Area)

  • 송락현;신동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1544-1546
    • /
    • 1999
  • The fabrication process for ceramic fuel cell with a large electrode area was investigated. A cofired cell of two layer, electrolyte/anode, yielded a power of $200mW/cm^2$. Its performance loss was mainly due to iR drop in the anode side. The performance of the cofired of three layer. cathode/electrolyte/ anode, was much lower than that of two layer, which resulted from the large iR drop and overvoltage at the cathode side. Also a flat cell with a large area of $7.7{\times}10.8cm^2$ was fabricated successfully and tested using ceramic and metallic interconnectors. The large cell with metallic interconnectror showed a good performance of 0.6 V, 4.5 A.

  • PDF