• Title/Summary/Keyword: landfill area

Search Result 219, Processing Time 0.028 seconds

오염토양 정화의 비용편익분석 -독일 오스나부릭 도시 사례-

  • 강동규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.20-24
    • /
    • 2004
  • The aim of this study was to analyse the cost-benefit-ratio of a soil remediation project. The target of the study was the 'Altablagerung Osnabrueck-Wueste' the largest inhabited former landfill site in Germany. The determination of benefit resulting from the soil remediation was quantified with the help of willingness-to-pay(WTP) analysis (contingent valuation method, CVM). 400 households participated in the survey. The average WTP was 6.5 Euro per household per month or 78 Euro per house-hold per year. The projected benefit generated by the remediation (consumer value) for the population in the landfill area was determined to be 0.7 million Euro per year. Factors which influence the will-ingness to pay were evaluated. The most important factors were age, garden use and the prevailing concern about personal health. A computation of the cost-benefit relationship was made on the basis of three different scenarios, which differed in terms of the projected benefits. Finally the economical efficiency of the project was determined. With a projection of 18 years and upwards the remediation of the soil is economically worthwhile.

  • PDF

Soft Ground Investigations Using Small Loop EM (소형루프 전자탐사법을 이용한 연약지반 조사)

  • Kim, Ki-Ju;Cho, In-Ky;Lim, Jin-Taik;Kyeung, Keu-Ha;Kim, Bong-Chan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.245-250
    • /
    • 2007
  • The small loop EM method is a fast and convenient geophysical tool which can give shallow subsurface resistivity distribution. It can be a useful alternative of resistivity method in conductive environment. We applied the multi-frequency small loop EM method for the investigation of a soft ground landfill site which was constructed on a tideland since the resistivity of the survey area is extremely low. 3D resistivity distribution was obtained by merging 1D inversion results and shallow subsurface structure can be interpreted. By comparing the result with the drilling log and measured soil resistivity sampled at 16 drill holes, we can get lot of information such as groundwater level, thickness of landfill, salinity distribution, depth to the basement and etc.

  • PDF

A Study on the Demand Modelling for District Cooling Energy Source (지역냉방 열원의 수요모형에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.11 no.4
    • /
    • pp.633-657
    • /
    • 2002
  • This study presents a demand modelling for landfill gas, which is used as alternative energy source for district cooling business. By analyzing the cost minimizing behavior of producer facing with three alternative energy sources such as electricity, cooling heat water, and gas, a demand function for landfill gas is derived from the optimal operating time of gas fired production facility, and estimated using unpublished data, which are associated with Seoul city's development plan for Sang-am area. The estimation results repeals that Seoul City could supply the land-fill gas of 13.76 million cubic meters each year at the price of about 16 won per cubic meters. However, if the investment costs associated with installation of gas collecting facilities are treated as sunk costs, annual amount of gas supplied is expected to increase to 14.22 million cubic meters at a lower unit price of 14.76 won.

  • PDF

A survey on the content of inorganic materials in ground-water of Northern Gyeonggi area (경기북부지역 지하수의 지역별 미량무기물질 함유실태 조사연구)

  • 오조교;손진석;배용수;정은희;박진호;황선민;정연훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2004
  • Ground water samples were collected from residential, green" industrial, landfill and mining area and analyzed for 23 inorganics from March to October in 2002. The results are as follows; 1. The detection frequencies of inorganic materials such as As, Ba, B, Mo, Ca, Mg, Al, Cu, Fe, Mn, Zn, Na, K were 7.2∼77.1% which showed that these inorganics were detected in many ground waters. 2. The detection frequencies of 7 inorganics(Cd, Cr, Ph, Se, Sb, Be, Tl) were commonly low at ranging from 0.42 to 2.5%. These inorganics were contained in ground water partially. 3. Three inorganics such as Hg, Ni, Ag were not detected in any ground-water samples. 4. Compared to the other areas, ground water samples from landfill area contained greater concentration in many inorgainics and then showed higher levels in industral, residential, mining and green area in order. 5. Compared to noted concentrations of bottled water, inorganic minerals including Ca, Mg, Na, K related to taste were fluent in target samples. The results showed that the average concentrations of Mg, Na, K were 4.0 mg/l, 14.7 mg/l, 1.5 mg/l respectively. 6. The concentrations of inorganics such as Sb, Ba, Mo, Be, Tl, K in some ground water samples exceeded the water quality standards of WHO, the US and UK. Especially, Ba, Mo, K also showed relatively high detection frequencies so these inorganics need to be considered as analytes in Korea Drinking Water Regulation in further study.

Case Study on the Investigation of Leachate Contamination from Waste Landfill Using Electromagnetic and Magnetic Methods (쓰레기 매립장 주변의 침출수 오염조사 사례: 전자탐사 및 자력탐사의 적용)

  • Son Jeong-Sul;Kim Jung-Ho;Yi Myeong-Jong;Ko Kyung-Seok
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • In this study, we offered the results of geophysical and geochemical survey on the municipal waste disposal area to delineate the size and extent of leachate contamination. Preliminary to intensive geochemical investigation, we performed two geophysical methods to characterize the survey area. Electromagnetic (EM) and magnetic method were used far site investigation. From the EM method, we can get the information of soil conductivity directly related to the leachate of the contaminations and from magnetic anomalies we can find the boundary of landfill which is not identified on the surface due to soil capping. The results of geophysical survey were well matched to those of geochemical method carried out inside and near the landfill. Electric conductivity (EC) of the groundwater sampled from low resistivity anomaly region of EM result was higher than background value and the border estimated from the magnetic survey showed good agreement with that estimated from the soil gas detection survey.

A Study On The Water Quality in Rural Area in Chuncheon-si (춘천시 일부 농촌 지역의 음용수 수질에 관한 조사연구)

  • Park, Sujung;Kim, Moon Kyung;Ki, Young Sun;Oh, So Rin;Shin, Mi-yeon;Oh, Ji Yoon;Byeon, Jae Cheol;Lee, Seong Min;Jung, Eun Hee;Kim, Eun Mi;Zoh, Kyung-Duk;Choi, Kyungho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.431-436
    • /
    • 2006
  • This study was conducted in the summer of 2005 in Shindong-myeon, Chuncheon-si, Gangwon-do to assess the quality of drinking water and to evaluate their potential pollutants. Ninety four water samples were collected from three classes of water supplies such as simple piped water, supplied own water and others (Supplied local water). Most residents used simple piped water (72.63%). 31.25% residents thought the water quality was bad and landfill was the main source of pollution that affected water quality. To correspond this perception, water quality was measured according to Drinking Water Quality Standard. The general bacteria, coliforms, and $NO_3-N$ exceeded the standard but the water qualities in these four areas were suitable for Drinking Water Quality Standard. The simple piped water showed low mean concentration of excess rate compared to supplied own piped water except general bacteria. Hardness, pH, and $NO_3-N$ showed significantly higher effects on drinking water quality. To evaluate the effect of effluent from landfill, water quality was measured according to distance and altitude. However, there was no effect of landfill effluent. To find out the effect of rainfall, we compared water quality of the year 2003 with that of 2005. The result showed significant differences in hardness and $NO_3-N$ concentration. This study confirmed that $NO_3-N$, coliforms, and general bacteria are main pollutant of water supply in rural community. Therefore, it is necessary to regularly maintain simple piped water supply, supplement sewer facilities, and educate residents about public health risk associated with drinking water in rural area.

Environmental Geophysical Survey of Abandoned Landfills for Contamination Evaluation: A Case Study (불량 매립지 오염평가를 위한 지구물리 탐사 사례연구)

  • Lee, Sung-Soon;Lee, Jin-Yong;Yoon, Hee-Sung;Lee, Kang-Kun;Kim, Chang-Gyun;Yu, Young-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.463-471
    • /
    • 2006
  • Electrical resistivity surveys were conducted at areas of abandoned landfills in Cheonan and Wonju. Geology and extent of leachate migration around the landfills were evaluated with collected resistivity data by 2-D and 3-D resistivity inverse modeling. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to examine possible pollution at the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system, which has not been in operation. To evaluate leachate leakage into the paddy fields, a total of 4 survey lines were used. According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and the leachate would reach the downgradient paddy fields. Low resistivity area was observed in the old reservoir area and it appeared to be derived from convergence of groundwater flows from the surrounding valley and the moist wet land. In addition, groundwater flow into the paddy fields occurs beneath the old reservoir embankment at depths of $7{\sim}8m$. This paper reports details of the resistivity surveys for the uncontrolled landfills.

The Ecological Management and Characteristics of Bird Communities at the World Cup Park in Seoul (서울시 월드컵공원 야생조류 군집 특성 및 생태적 관리방안)

  • Han Bong-Ho;Kim Jeong-Ho;Son Byong-Dof;Lee Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.5 s.112
    • /
    • pp.43-56
    • /
    • 2005
  • This study was conducted to examine the inhabitation of wild birds at the World Cup Park and to offer the Park ecological management data. Land use md actual vegetation were examined to analyze the inhabitation of wild birds. Characteristics of bird communities were analyzed by dominance, density, diversity index and guild concept. You compare inhabitation before and after the Park was built. We classified the land use and actual vegetation into twenty-six types. Robinia pseudoacacia dominated the study area. Pyeonghwa Park and Nanji-cheon Park were simple-layer structures composed of alien woody species. The observed birds after the World Cup Park included 33 families 77 species, and 9,751 individuals. Among Wild Life types, the shrub and bush type was dominant. There were 26 species of resident birds, 20 species of summer visitors, 18 species of winter visitors, and 12 species of passage migrants. The following numbers of species and individuals were observed: in Hanul park, 38 species, 3,151 individuals; in Noul park, 45 species, 2,061 individuals; in Nanji-cheon park, 42 species, 2,742 individuals; in Pyeonghwa park, 29 species, 875 individuals; and in Maebongsan(Mt.) area, 35 species, 922 individuals. Species diversities for each area were as follows: Noul park, 2.613; Hanul park, 2,301; Nanji-cheon, 2.228; and Pyeonghwa park, 2,019; and each season: summer, 2.652; spring, 2.650: winter, 2.561; and autumn 2.176. The diversity of species increased from 1.135 in 1994 to 2.324 in 2001. We recommended that the park be differented into different ecological areas in order to encourage the appearance of wild birds at the World Cup Park. The management area was divided into three districts(conservation area, preservation and restoration area, use area). The conservation area was established to the west of a waste landfill and in the downstream area of NanJi-cheon, the preservation and restoration area was established in the midstream area of Nanji-cheon, and the use area was established in the buffer zone of Pyeonghwa Park and the Nanji pond greenspace.

Regional Optimization of Food Waste Management - Focused on Three Cities in Kyungnam Province - (음식물쓰레기 관리의 광역적 최적화 방안 - 경남 3개 도시를 중심으로 -)

  • Lee, Myung-Hi;Park, Jung-Seok;Kin, Jong-Oh
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.7 no.1
    • /
    • pp.53-66
    • /
    • 1999
  • Limited landfill area and finance as well as a large generation of food wastes, have called for systematic approaches towards potential cost savings. In this study, the regional management system of food wastes generated from the residential and commercial sources was considered in three cities bounded each other; Changwon, Masan, and Jinhae city. Total thirteen alternatives were established and compared by applying the WRAP (Waste Resource Allocation Program). The following results were obtained: 1. While relatively small amounts were generated from the commercial sources such as cafeteria, restaurants, and market facilities, almost 80% of food wastes were generated from the residential sources. 2. Unit costs for food waste management in three cities were different according to their present situation such as the type and location of major generation sources and treatment facilities. Especially, the highest cost appeared in Jinhae city due to the most expensive construction of coastal landfill site. 3. Considering proper revenue, the whole conversion of food waste into animal feed was selected as the optimal alternative and represented 60% to 74% of the management cost of the whole landfill alternative in all cities. Comparing the other alternatives, composting of food waste was more economical than landfill alternative and the incineration was the most expensive alternative. 4. Some of the regional management systems using common food waste processing facilities together in three cities showed to be more economical than the single management system. Therefore, more detailed research for the regional management systems of food waste was recommended.

  • PDF

Preliminary Study for an Application to Environmental Impact Assessment of Remote Sensing Data (원격탐사자료의 환경영향평가 활용을 위한 기초연구)

  • Mun, Hyun-Saing;Kim, Myung-Jin;Kang, In-Goo;Bang, Kyu-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.1
    • /
    • pp.59-64
    • /
    • 1995
  • Environmental Impact Assesment(EIA) is composed of various procedures, such as screening, scoping, inventory survey, prediction, assessment, mitigation measure, alternative assessment, and post management. Remote sensing introduced lately begins to be applied ecosystem and land use in inventory survey and assessment of EIA. This study explains on land use classification, buffering analysis of residential area, and overlaying analysis of odor predictive data with residential area for application to EIA with remote sensing data. Residential area extracted from land use classification of remote sensing provides effectively buffering analysis of residential area in selection of landfill site with GIS. It could assess also residential effect to an offensive odor by overlaying analysis. Application methods in EIA should be enlarged to assess effectively.

  • PDF