• Title/Summary/Keyword: laminated cap

Search Result 6, Processing Time 0.033 seconds

Design of Preventing Deviation System of Magnet for high Speed Rotated Surface Mounted Permanent Magnet Synchronous Generator (고속으로 회전하는 표면부착형 영구자석 동기발전기의 마그넷 이탈방지 시스템 설계)

  • Kim, Youngmin;Kim, Jungsu;Park, Sunho;Lim, Minsoo;Bang, Johyug;Ryu, Jiyune
    • Journal of Wind Energy
    • /
    • v.5 no.1
    • /
    • pp.50-55
    • /
    • 2014
  • Surface Permanent-Magnetic-Synchronous-Generator (SPMSG) discussed in the present study has operational characteristics such as high rotational speed over 1,000 rpm and centrifugal force of 12 kN·m for each magnet. Structure-development analysis for the minimization of rotor-core weights and the maximization of thermal emission is performed by applying the aluminum-laminated cap which combines the advantages of IPM and SPM in order to overcome the difficulty that attaching the magnet to rotor-core only with an adhesive. In this study, the simulations in terms of structure and electromagnetic were performed with the variable parameters such as shape and thickness of laminated-cap and division method of magnet. As a result, condition for minimized centrifugal force with minimum loss is derived.

Analysis of Physical Performance, Hygiene and Safety of Silicone-Laminated Stretch Material (실리콘이 라미네이팅된 신축성 소재의 위생 및 안전성과 역학적 성능)

  • Kwon, Myoung-Sook;Jung, Gi-Soo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.1 s.160
    • /
    • pp.77-84
    • /
    • 2007
  • The purpose of this study was to investigate and to compare the performances of silicone laminated materials sold for swimming cap in market, to get the basic data for product development. We selected 4 specimens and tested their air permeability, waterproofness and breathability. We also tested the physical and mechanical properties of the specimens using KES system. Silicone-laminated material was not bursted on high hydraulic pressure since silicone membrane gave waterproofness while PU/Polyester substrate gave elasticity. It didn't have air permeability and breathability at all. Any toxic materials such as Formaldehyde, Deldrin, PCP, Amin, TDBPP were not detected in silicone-laminated material and other materials. Silicone-laminated material had higher stretchability with the low force but it had lower elastic recovery and shape stability comparing to PU laminated material. It had lower flexibility than PU laminated material. It had lower unrecoverable amount in shearing direction. Friction coefficient was higher in silicone-laminated material than PU laminated material due to its surface stickiness. It was compressed easily and its compression resiliency was higher with compared to PU laminated material.

Optimum Shape for Buckling and Post-Buckling Behavior of a Laminated Composite Panel with I-type Stiffeners

  • Lee, Gwang-Rog;Yang, Won-Ho;Sub, Myung-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1211-1221
    • /
    • 2002
  • A shape optimization of stiffener was conducted to increase buckling load or failure load with stiffened laminated composite panel of I-type under compression loading. Design variables are cap length, web length, and/or thickness under the constraint of volume constancy. The objective function is buckling load and failure load of post-buckling based on Tsai-Hill theory using ABAQUS 5.8 for analysis and Optimizer on Broydon-Fletcher Goldfarb-Sharno Method and Augmented Lagrange Multiplier Method. The effects of relative length of a web and a cap of stiffener on buckling load and failure load of post-buckling were investigated with the results of optimum design.

A Study on Lamination Property of Superconducting Coated Conductor

  • Kim, T.H.;Oh, S.S.;Ha, D.W.;Kim, H.S.;Ko, R.K.;Song, K.J.;Ha, H.S.;Yang, J.S.;Park, Y.M.;Oh, J.K.;Jung, K.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.161-162
    • /
    • 2005
  • 2G HTS coated conductor wire consists of textured substrate, buffer layer, superconduct layer, Ag cap layer, stabilizer. For practical application filed, coated conductor have mechanical and electrical stability and environment protection properties. This property Cu and stainless steel strip is laminated to Ag cap layer as stabilizer materials. Lamination process join stabilizer material strip and Ag cap layer with soldering method. we have laminated HTS with continuous dipping soldering process different stabilizer Cu and stainless steel strip and changed lamination process condition. The effect of lamination stabilizer and process condition has been investigated mechanical and electrical properties.

  • PDF

Buckling and Postbuckling Behavior of Stiffened Laminated Composite Panels (보강된 복합적층 판넬의 좌굴 및 좌굴후 거동 연구)

  • Lee, In-Cheol;Gyeong, U-Min;Gong, Cheol-Won;Hong, Chang-Seon;Kim, Cheon-Gon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3199-3210
    • /
    • 1996
  • The buckling and postbuckling behaviors were sutdied analytically and experimentally for stiffened laminated composite panels under compression loading. The panels with I-, blade, -and hat-shapeed stiffeners were investigated. In the analysis, the stiffened panels were anlyzed using the nonlinear finite element method combined with an improved arc-length method. The progressive failure analysis was done by adopting the maximum stress criterion and complete unloading failure model. The effects of the fiber angles were investigated on the buckling and postbuckling behaviors. In the experiment, the web and the lower cap of each stiffener were formed by the continuous lay-up of the skin for cocuring the stiffened panels. Therefore, the separation between stiffener and skin was not found in the junction part even after postbuckling ultimate load and the stiffened panels had excellent postbuckling load carrying capacity. A shadow moire thchnique was used to monitor the out-of-plane deformations of the panels. The piezoelectric films were attached to the panels to get the failure characteristics of the panel. The analytical results on the buckling load, postbuckling ultimate load, and failure pattern showed good agreement with the experimental results.

A Study on the Improvement of Cold Protective Clothing for Mailman (우편배달원 방안복 개선을 위한 연구)

  • Kwon, Myoung-Sook;Seok, Hye-Jung
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.8
    • /
    • pp.14-23
    • /
    • 2007
  • The purpose of this study was to investigate the present condition of cold protective clothing for mailman, to improve its design in movement, fitness, and other functions, and supply basic data for its performance evaluation. The results are as follows : The 46.60% of those questioned did not satisfy current clod protective clothing fer mailman. Especially, they considered dissatisfactory in properties such as waterproof, comfort, activity, and sweat absorption. The newly developed cold protective clothing is two-piece style composed of jacket and pants. Both jacket and pants are composed of inner and outer clothing individually. In both jacket and pants, their outer clothing's material was waterproof, windproof, and breathable shell fabric on which PTFE film laminated and their inner clothing's material was 100% polyester Polar polis to have better insulation property. The jacket has attachable cap which can be used as rain gear and set-in sleeve with stand collar. It also had big outside patch pockets and side seam pockets to ensure enough storage space. The pants have knee pads to give free movement to knees and slant side pockets. Inner clothing of both jacket and pants can be worn during working inside without out clothing. Insulation of the newly developed cold protective clothing was not better than current one except right hand, left hand and left foo. It is considered that is because thickness of material is the most important factor to influence insulation.