• 제목/요약/키워드: laboratory testing

검색결과 1,704건 처리시간 0.026초

Study on the Removal Efficiency of Nitrogen and Phosphorus in Wastewater Treatment System Using Magnetite Powder (자철광 분말을 이용한 하수처리시스템의 질소, 인 제거효율에 관한 연구)

  • Jo, Eun-Young;Park, Seung-Min;Yeo, In-Seol;Moon, Joeng-Sik;Park, Ju-Young;Kim, Jong-Cheol;Kim, Yang-Seob;Park, Chan-Gyu
    • The KSFM Journal of Fluid Machinery
    • /
    • 제18권2호
    • /
    • pp.43-47
    • /
    • 2015
  • As water quality regulations have tightened, many studies to improve wastewater treatment efficiency have been performed. In this study, magnetite powder was used to maintain a high concentration of MLSS in lab-scale wastewater treatment system. After magnetite powder injection, MLSS concentration was above 8,000 mg/L and it was 3.2 times higher than control group(2,500 mg/L). In addition, nitrogen removal efficiency and phosphorus removal efficiency comparing with the control group was increased 20.5% and 11%, respectively.

A Study on a Small-scale Wastewater Treatment System Using MBR and IPNR (MBR과 IPNR을 이용한 소규모 하수처리 시스템에 관한 연구)

  • Kim, Young-Hee;Jo, Eun-Young;Yeo, In-Seol;Park, Seung-Min;Park, Chan-Gyu
    • The KSFM Journal of Fluid Machinery
    • /
    • 제18권2호
    • /
    • pp.37-42
    • /
    • 2015
  • In the purpose of this study, we investigate the characteristics of the pilot-scale wastewater treatment system applied to BAF, MBR and IPNR as examining the removal efficiency of organic pollutants and operating factors in small decentralized wastewater treatment systems, and operating factors. For long-term operation period of more than nine months, pilot-scale plant operating results appeared very stable. This results were the removal efficiency of BOD was 80.3% above and removal efficiency of COD with an average of about 91.0%, satisfied the final effluent water quality standards. TN in the final effluents was the average concentration of 7.9 mg/L, was satisfactory water quality standards 10 mg/L of TN.

Accurate Detection of a Defective Area by Adopting a Divide and Conquer Strategy in Infrared Thermal Imaging Measurement

  • Jiangfei, Wang;Lihua, Yuan;Zhengguang, Zhu;Mingyuan, Yuan
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1644-1649
    • /
    • 2018
  • Aiming at infrared thermal images with different buried depth defects, we study a variety of image segmentation algorithms based on the threshold to develop global search ability and the ability to find the defect area accurately. Firstly, the iterative thresholding method, the maximum entropy method, the minimum error method, the Ostu method and the minimum skewness method are applied to image segmentation of the same infrared thermal image. The study shows that the maximum entropy method and the minimum error method have strong global search capability and can simultaneously extract defects at different depths. However none of these five methods can accurately calculate the defect area at different depths. In order to solve this problem, we put forward a strategy of "divide and conquer". The infrared thermal image is divided into several local thermal maps, with each map containing only one defect, and the defect area is calculated after local image processing of the different buried defects one by one. The results show that, under the "divide and conquer" strategy, the iterative threshold method and the Ostu method have the advantage of high precision and can accurately extract the area of different defects at different depths, with an error of less than 5%.

Direct-to-consumer genetic testing

  • Kim, Jong-Won
    • Genomics & Informatics
    • /
    • 제17권3호
    • /
    • pp.34.1-34.3
    • /
    • 2019
  • Direct-to-consumer (DTC) genetic testing is a controversial issue although Korean Government is considering to expand DTC genetic testing. Preventing the exaggeration and abusing of DTC genetic testing is an important task considering the early history of DTC genetic testing in Korea. And the DTC genetic testing performance or method has been rarely reported to the scientific and/or medical community and reliability of DTC genetic testing needs to be assessed. Law enforcement needs to improve these issues. Also principle of transparency needs to be applied.

Improving Performance Certification of Aviation Security Equipment (항공보안장비 성능인증기술 고도화 방안 연구)

  • Jung, Jin Hyeong;Kim, Ki-Yeon;Yoon, Yeon Ah;Kim, Na Yeon;Sim, Hyun Su;Lee, Seung Hoon;Ha, Da Som;Seol, Eun-Suk;Han, Soo Jin;Park, Soo-Hong;Yu, Sang Woo;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • 제48권1호
    • /
    • pp.187-199
    • /
    • 2020
  • Purpose: This study suggests how to upgrade performance certification technology. Current performance certification of aviation security equipment and the requirements thereof were analyzed. Methods: The performance certification of aviation security equipment worldwide and identified issues with the domestic certification system were compared. The government must upgrade certification in terms of technical standards, the assessment methodology used, and the operating system. Results: Three principal conclusions were drawn. First, certification requirements must be based on a review of the technical literature and real-world experience. Second, development priorities must be set by reference to assessment techniques. Third, both research on the certification system and improvements thereof are essential. Conclusion: Certification of aviation security equipment performance requires gradual upgrading.

Studies on the Thin Rubber Coated Fabrics. (Part 2) Physical Properties of the Coated Fabric with Rubber Compounds Having Different Viscosity (박막(薄膜) Rubber Coated Fabrics에 관(關)한 연구(硏究)(제2보(第2報)) Viscosity가 다른 배합(配合)고무를 각종(各種) 원반(原反)에 도포(塗布)했을때의 물리적(物理的) 성능(性能)에 대(對)하여)

  • Kim, Joon-Soo;Lee, Myung-Whan;Yum, Hong-Chan;Lee, Sook-Ja;Rhim, Kwang-Kew
    • Elastomers and Composites
    • /
    • 제1권1호
    • /
    • pp.49-55
    • /
    • 1966
  • Based upon the results of the previous work, the experiments are concentrated on the improvement of the durability of rubber coated fabrics as a rain garment material. To obtain a much lighter and durable coated fabric, several kinds of light weight cotton prints having almost equal density in warp and fillingwise were chosen. Rubber coating on these prints was made by topping and spreading process using rubber compound of various viscosity, and the physical properties of final product were analysed and interpreted in terms of adhesion and durability. The results are as follows. 1. Any noticeable difference between two coating processes was not found in terms of physical properties. 2. Base fabrics should be dipped once into a dilute rubber compound before coating operation in order to obtain a uniform adhesion and physical properties, and the optimum range of the viscosity of dipping paste are from 100 poise to 200 poise. 3. Generally, the tearing strength of the coated fabrics is inversely proportional to the adhesion. 4. It was assumed that the increase of the water proofness after water immersion on the finished material which have dense base fabric is chiefly due to the swelling of the cellulosic fiber.

  • PDF

Expression of Codon Optimized β2-Adrenergic Receptor in Sf9 Insect Cells for Multianalyte Detection of β-Agonist Residues in Pork

  • Liu, Yuan;Wang, Jian;Liu, Yang;Yang, Liting;Zhu, Xuran;Wang, Wei;Zhang, Jiaxiao;Wei, Dong
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권9호
    • /
    • pp.1470-1477
    • /
    • 2019
  • ${\beta}_2$-adrenergic receptor (${\beta}_2-AR$) was expressed efficiently using Bac-to-Bac Baculovirus Expression System in Sf9 cells as a bio-recognition element for multianalyte screening of ${\beta}$-agonist residues in pork. Sf9 cells were selected as the expression system, and codon optimization of wild-type nucleic acid sequence and time-dependent screening of expression conditions were then carried out for enhancing expression level and biological activity. Under optimum conditions of multiplicity of infection (MOI) = 5 and 48 h post transfection, the protein yield was up to 1.23 mg/ml. After purification by chromatographic techniques, the purified recombinant protein was applied to develop a direct competitive enzyme-linked receptor assay (ELRA) and the efficiency and reliability of the assay was determined. The IC50 values of clenbuterol, salbutamol, and ractopamine were 28.36, 50.70, and $59.57{\mu}g/l$, and clenbuterol showed 47.61% and 55.94% cross-reactivities with ractopamine and salbutamol, respectively. The limit of detection (LOD) was $3.2{\mu}g/l$ and the relevant recoveries in pork samples were in the range of 73.0-91.2%, 69.4-84.6%, and 63.7-80.2%, respectively. The results showed that it had better performance compared with other present nonradioactive receptorbased assays, indicating that the genetically modified ${\beta}_2-AR$ would have great application potential in detection of ${\beta}$-agonist residues.

Comparison for Loss Rate of Low Concentration Nitrous Oxide in Tedlar Bag and Aluminium-Polyester Bag (테들러백과 알루미늄-폴리에스터백에 보관된 저농도 아산화질소의 유실율 비교)

  • Lee, Woo Chan;Park, Sung Bin;Ko, Young Hwan;Hyun, Seung Min;Yoon, Kyoon Duk
    • Journal of Climate Change Research
    • /
    • 제8권1호
    • /
    • pp.31-39
    • /
    • 2017
  • The emission quantity of nitrous oxide is second largest among non-$CO_2$ greenhouse gas in Korea. In this study, we investigated loss rate of nitrous oxide which was filled in PVF and Al-PE bag as time goes on. Concentrations of tested samples were about 25 ppmv, 50 ppmv, 75 ppmv prepared by standard reference gas. In case of all experiments, loss rate of PVF bag was higher than Al-PE bag. After 18 days, loss rate of PVF bag was from 29.7% to 38.6% while Al-PE bag was from 21.7% to 23.7%. Especially the differential growed bigger when initial concentration of $N_2O$ in PVF bag was lower. And we also studied the effect of cock opening/closing procedures on loss rate. Prepared samples in experimental group were analyzed several times for 20 days and samples in control group were analysed only 1 time after 20 days. The experimental results showed that cock opening/closing procedures appeared to have little impact on loss rate.

Differences in Colistin-resistant Acinetobacter baumannii Clinical Isolates Between Patients With and Without Prior Colistin Treatment

  • Park, Yu Jin;Hong, Duck Jin;Yoon, Eun-Jeong;Kim, Dokyun;Choi, Min Hyuk;Hong, Jun Sung;Lee, Hyukmin;Yong, Dongeun;Jeong, Seok Hoon
    • Annals of Laboratory Medicine
    • /
    • 제38권6호
    • /
    • pp.545-554
    • /
    • 2018
  • Background: The increasing morbidity and mortality rates associated with Acinetobacter baumannii are due to the emergence of drug resistance and the limited treatment options. We compared characteristics of colistin-resistant Acinetobacter baumannii (CR-AB) clinical isolates recovered from patients with and without prior colistin treatment. We assessed whether prior colistin treatment affects the resistance mechanism of CR-AB isolates, mortality rates, and clinical characteristics. Additionally, a proper method for identifying CR-AB was determined. Methods: We collected 36 non-duplicate CR-AB clinical isolates resistant to colistin. Antimicrobial susceptibility testing, Sanger sequencing analysis, molecular typing, lipid A structure analysis, and in vitro synergy testing were performed. Eleven colistin-susceptible AB isolates were used as controls. Results: Despite no differences in clinical characteristics between patients with and without prior colistin treatment, resistance-causing genetic mutations were more frequent in isolates from colistin-treated patients. Distinct mutations were overlooked via the Sanger sequencing method, perhaps because of a masking effect by the colistin-susceptible AB subpopulation of CR-AB isolates lacking genetic mutations. However, modified lipid A analysis revealed colistin resistance peaks, despite the population heterogeneity, and peak levels were significantly different between the groups. Conclusions: Although prior colistin use did not induce clinical or susceptibility differences, we demonstrated that identification of CR-AB by sequencing is insufficient. We propose that population heterogeneity has a masking effect, especially in colistin non-treated patients; therefore, accurate testing methods reflecting physiological alterations of the bacteria, such as phosphoethanolamine-modified lipid A identification by matrix-assisted laser desorption ionization-time of flight, should be employed.