• 제목/요약/키워드: laboratory model tests

검색결과 891건 처리시간 0.027초

Investigation of the tensile behavior of joint filling under experimental test and numerical simulation

  • Fu, Jinwei;Haeri, Hadi;Sarfarazi, Vahab;Marji, Mohammad Fatehi;Guo, Mengdi
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.243-258
    • /
    • 2022
  • In this paper, tensile behavior of joint filling has been investigated under experimental test and numerical simulation (particle flow code). Two concrete slabs containing semi cylinder hole were prepared. These slabs were attached to each other by glue and one cubic specimen with dimension of 19 cm×15 cm×6 cm was prepared. This sample placed in the universal testing machine where the direct tensile stress can be applied to this specimen by implementing a special type of load transferring device which converts the applied compressive load to that of the tensile during the test. In the present work, two different joint filling thickness i.e., 3 mm and 6 mm were prepared and tested in the laboratory to measure their direct tensile strengths. Concurrent with experimental test, numerical simulation was performed to investigate the effect of hole diameter, length of edge notch, filling thickness and filling length on the tensile behavior of joint filling. Model dimension was 19 cm×15 cm. hole diameter was change in four different values of 2.5 cm, 5 cm, 7.5 cm and 10 cm. glue lengths were different based on the hole diameter, i.e., 12.5 cm for hole diameter of 2.5 cm, 10 cm for hole diameter of 5 cm, 7.5 cm for hole diameter of 7.5 cm and 5 cm for hole diameter of 10 cm. length of edge notch were changed in three different value i.e., 10%, 30% and 50% of glue length. Filling thickness were changed in three different value of 3 mm, 6 mm and 9 mm. Tensile strengths of glue and concrete were 2.37 MPa and 6.4 MPa, respectively. The load was applied at a constant rate of 1 kg/s. Results shows that hole diameter, length of edge notch, filling thickness and filling length have important effect on the tensile behavior of joint filling. In fixed glue thinks and fixed joint length, the tensile strength was decreased by increasing the hole diameter. Comparing the results showed that the strength, failure mechanism and fracture patterns obtained numerically and experimentally were similar for both cases.

아스팔트 혼합물의 점탄성과 차량의 이동 속도가 포장 거동에 미치는 영향 (Asphalt Concrete Pavement Response to Moving Load and Viscoelastic Property)

  • 조명환;김낙석;서영국
    • 대한토목학회논문집
    • /
    • 제28권4D호
    • /
    • pp.485-492
    • /
    • 2008
  • 본 논문에서는 차량의 주행속도가 아스팔트 포장의 변형률 거동에 미치는 영향을 알아보기 위하여 현장시험을 실시하고 그 결과를 3차원 유한요소해석과 비교, 분석하였다. 한국도로공사 시험도로에서 기층의 두께가 다른 세 단면(A2, A5, A8)을 선정하고, 각 단면별로 세 가지의 주행속도(25, 50, 80km/hr)에 대한 종, 횡방향 변형률을 측정하였다. ABAQUS를 이용한 수치해석에서는 시험차량인 덤프트럭(단축-탠덤축)의 축하중을 단계하중(step loading)으로 모사하였으며, 시험도로 아스팔트 혼합물에 대한 선형 점탄성 물성 계수(E(t))를 적용하여 보다 현실적인 거동해석을 실시하였다. 주어진 시험 조건에서 아스팔트 층 하부에서 측정한 종, 횡방향 변형률의 차이(이방성)는 모든 단면에서 목격되었고, 수치해석결과 차량의 주행속도가 증가함에 따라 임계 지점에서 발생하는 최대 변형률의 크기는 감소하는 것으로 예측되었다. 또한, 최대변형률의 크기도 횡방향 변형률이 종방향 변형률에 비하여 약 27% 정도 작았으며, 차량의 속도가 증가함에 따라 최대 변형률의 감소폭도 횡방향이 약간 큰 것으로 나타났다.

급.만성 기관지염 환자에서 엘도스$^{(R)}$(Erdosteine)의 임상효과 -염산 암브록솔과의 무작위 이중맹검 비교시험- (Clinical Efficacy of Erdosteine in Patients with Acute or Chronic Bronchitis -A Randomized, Double Blind, Comparative Study vs. Ambroxol-)

  • 김석찬;이상학;송소향;김영균;문화식;송정섭;박성학
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권6호
    • /
    • pp.1296-1307
    • /
    • 1997
  • 연구배경 : Erdosteine은 만성 기관지염 급성 악화시는 물론 만성 폐색성 기관지염 치료제로 개발된 Thiol 유도체로서 점액조절작용, 항산화작용이 있으며, 특히 위장관 부작용이 거의 없다. 본 연구에서는 현재 유효성 및 안전성이 입증되어 임상에서 많이 처방되고 있는 Ambroxol과의 비교임상연구를 통해 급성 및 만성 기관지염 환자에서 Erdosteine의 임상적 유용성을 알아보고자 하였다. 방 법 : 본 연구는 무작위 이중맹검 비교시험으로서 전향적 연구방법으로 수행되었다. 급 만성 기관지염으로 다량의 객담배출 혹은 객담배출곤란을 주증상으로 하는 80명을 무작위로 할당하여 Erdosteine 투여군에는 1일 2회, 1회 300mg, Ambroxol 투여군에는 1일 2회, 1회 30mg을 총 7일간 투여하였다. 1차 효과평가기준으로는 객담배출횟수, 객담량, 객담배출용이도, 객담점도, 기침정도, 호흡곤란을 포함한 자각증상이 평가되었고, 2차 효과평가기준으로는 동맥혈가스검사, 폐기능검사가 평가되었다. 안전성은 부작용과 임상병리검사로 평가하였다. 총 80명의 환자 중 61명(Erdosteine군 : 31명, Ambroxol군 : 30명)이 본 연구를 종료하였고 19명은 중도 탈락되었다. 결과의 분석은 paired t-test, ANOVA test, multivariate t2-test, Repeated measures analysis of covariance, two sample t-test, Loglinear-Logit model analysis, Fisher's exact test를 이 용하여 유의성을 검정하였다. 결 과 : 1) 두 군간의 환자배정에 있어서 인구학적, 임상적 특징은 차이가 없었다. 2) 동맥혈가스검사, 폐기능검사에서는 두 군간의 차이는 없었고, 자각증상에서는 Erdosteine군은 객담 배출횟수, 객담량, 객담배출용이도, 객담점도, 기침정도, 호흡곤란에서, Ambroxol군은 객담배출횟수, 객담량, 객담배출용이도, 객담점도, 기침정도에서 유의하게 호전을 보였다. 통계적으로 유의하지 않았으나 Erdosteine군이 Ambroxol군에 비해 더 유의하게 호전되는 경향을 보였다($\alpha$=0.05). 3) 혈액학적검사, 혈액화학적검사 및 소변검사에서는 각 군 모두 임상적으로 의미있는 변화는 없었고 두 군간의 차이도 없었으며, 자각증상에서는 Ambroxol군에서만 4명이 연구 종료시까지 부작용이 소실되지 않았고 2명은 연구를 중단하였으나 두 군간의 차이는 없었다. 4) 각 약제의 최종효과평가에서 Erdosteine군은 31명 중 아주좋은효과 11명, 좋은효과 12명, 경도효과 6명, 무효과 2명, 악화 0명이었고 Ambroxol군은 30명 중 아주좋은효과 6명, 좋은효과 14명, 경도 효과 5명, 무효과 4명, 악화 1명이었으며 Erdosteine군이 Ambroxol군에 비해 증상이 개선될 확률이 약 2.5배만큼 높았다 (p<0.05). 결 론 : Erdosteine은 급성 및 만성 기관지염 환자의 치료에 있어 그 효과와 안전성에 있어서 우수한 약물이라고 할 수 있다.

  • PDF

용담댐 건설후 하류부 하천 생태계의 탁수영향 평가 (Ecological Health Assessments on Turbidwater in the Downstream After a Construction of Yongdam Dam)

  • 김자현;서진원;나영언;안광국
    • 생태와환경
    • /
    • 제40권1호
    • /
    • pp.130-142
    • /
    • 2007
  • 본 연구에서는 용담댐의 탁수 방류로 인한 하류 하천의 영향을 알아보기 위하여 생태계 건강성 평가 모델, 물리적 서식지 평가 모델, 해부학적 건강성 평가 모델을 적용하였다. 건강성 평가 결과 $S1{\sim}S4$의 생태계 건강도는 평균 43으로 최적${\sim}$ 양호 상태였고, 물리적 서식지 건강도는 평균 154로 양호상태로 나타나 건강도가 양호하게 유지되고 있는 것으로 나타났다. 한편 개체의 건강도를 평가하는 해부학적 건강도 평가 결과 10개 메트릭에서 이상증상이 나타나지 않아 어류 건강성에 대한 영향은 없는 것으로 판단되었다. 한편, 부유물의 증가에 따른 어류 아가미의 전자현미경적 영향 분석을 위해 탁도 처리군 및 대조군의 비교분석 결과에 따르면, 어류 아가미에서 많은 부유물 미세 입자가 관찰되어 고탁도에 장기간 노출될 경우 건강성에 영향을 미칠 가능성이 있을 것으로 사료되었다. 또한, 탁도 증가에 따른 부유사 이동에 의한 어류의 물리적 서식지 영향 분석(특히, 하상 매몰도 및 하상특성 분석)을 위해 서식지 건강성 평가모델을 적용 평가한 결과에 따르면, 대상 조사지역$(S1{\sim}S4)$이 대조군 지역(C1, C2)보다 더 좋은 것으로 나타났다. 즉, 부유사의 증가는 현재의 결과로는 서식지 건강도에 영향을 주지 않는 것으로 나타나 어류의 먹이사슬, 산란장 및 서식처에 대한 부정적 영향은 없는 것으로 사료되었다. 한편, 이런 결과는 단기간 연구 결과에 의한 현재 상태의 건강도 평가의 결과이지만 향후 탁수가 지속될 경우 수 환경이 어떻게 변할 것인가에 대해서는 사후 지속적인 모니터링이 이루어져야 하며, 향후 $3{\sim}5$년 후의 지속적인 모니터링을 실시할 경우 용담댐 건설에 의한 생태 건강도가 어떻게 변할 것인지에 대한 정보를 제공하기 때문에 지속적인 모니터링이 요구된다.

Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석 (Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff)

  • 이준호;방기웅;홍성철
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone은 높은 수면적부하율 운전이 가능하고, 구동부분이 없고, 운전 및 유지관리비가 적게 소요되어 미세입자물질제거에 효과적인 장치로 다양한 산업 분야에서 활용되고 있다. Hydrocyclone에 나선형 유입부를 통해 직각으로 유입되어 중력이 아닌 원심력에 의해 입자물질이 하부배출구로 분리되고 처리수는 vortex finder를 통해 배출된다. 입자분리에 hydrocyclone은 많은 장점을 가지고 있음에도 불구하고 도시지역 강우유출수 처리사례는 드문 실정이다. 본 연구에서는 변형된 hydrocyclone과 perlite 여재를 조합한 hydrocyclone filter (HCF)을 이용하여 강우유출수내 미세입자의 제거능을 분석하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환 수지, 도로측구 퇴적물질, 상업지역 맨홀퇴적물질, 그리고 실리카겔 등이다. 하부배출부와 vortex finder 구조를 달리하여 HCFopen system과 HCF-closed system으로 구분하여 처리능을 분석하였다. HCF장치는 아크릴 수지를 이용하였는데 hydrocyclone의 직경은 120 mm이고 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 운전조건별 유입수 농도와 입경을 다양하게 적용하였고 SS와 COD농도를 분석하여 처리효율을 산정하였다. HCF-open system의 경우 운전 가능한 최대 수면적부하율은 700 $m^3/m^2$/day이었고 HCF-closed system의 경우 수면적부하율 1,200 $m^3/m^2$/day까지이다. HCF-open system 운전결과 HCFclosed system에 비교하여 평균 수면적부하율은 2배 이상 높게 운전이 가능하며 처리효율도 8~20% 이상 향상되는 것으로 분석되었다. 또한 유입수 SS농도가 높을수록 처리효율이 증가하며, 입경이 클수록 수면적부하율의 변화에 대한 처리효율의 영향이 적은 것으로 분석되었다. HCF-closed system의 실험을 통한 수면적부하율 변화에 대한 실리카겔입자의 제거 효율과 CFD입자추적기법을 이용한 예측 처리효율을 비교한 결과 CFD에 예측효율이 실제실험결과와 비교하여 다소 높게 나타나지만 처리효율의 경향은 매우 유사하게 나타나 CFD추적기법을 이용한 HDS유형 처리장치 설계 시 유용한 도구로 활용될 수 있을 것으로 판단된다.

슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향 (Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection)

  • 최명신;조인중;안종문;신성우
    • 콘크리트학회논문집
    • /
    • 제19권4호
    • /
    • pp.515-525
    • /
    • 2007
  • 본 연구는 주거용 고층 건물에서 폭넓게 사용되고 있는 플랫플레이트 구조에서 장방형 기둥-슬래브 접합부를 대상으로 실시한 4개의 실험 결과를 분석한 것이다. 이 연구의 목적은 지진하중과 같이 반복적으로 작용하는 횡하중에 대하여 기둥 단면의 형상비 (${\beta}_c=c_1/c_2$=횡하중과 나란한 방향의 기둥 단면의 크기/횡하중과 직교 방향의 기둥 단면의 크기)에 따른 접합부의 이력 거동을 비교 평가한 것이다. 기둥 단면의 형상비는 $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$으로 선정되었고, 기둥 또는 슬래브 위험단면의 둘레 길이 $(b_o)$가 일정하지 않을 경우 공칭 수직 전단력 $(V_c)$의 크기기 변화하여 중력 전단력비의 차이가 발생하기 때문에 기둥 양변의 크기를 동시에 변화시켜서 $b_o$가 일정해 지도록 기둥 단면의 크기를 결정하였다. 그리고 슬래브 휨 철근비와 중력 전단력비 $(V_g/V_c)$ 등 접합부의 이력 거동에 영향을 줄 수 있는 다른 영향 인자들은 일정한 조건으로 계획하여 기둥 형상비의 영향을 고찰할 수 있도록 하였다. 일정 수직하중과 반복횡하중이 작용하는 슬래브_기둥 접합부의 실험을 통해서 뚫림전단파괴 양상과 균열 패턴, 철근 및 콘크리트의 변형률, 접합부의 강도와 강성, 그리고 변형 능력 등을 기둥 형상비 변수에 따라 분석하였다. 또한, ACI 318-05 설계기준의 편심 전단응력 모델에 의한 전단응력을 실험 결과와 비교하여 평가하였고, 실험 결과에 기초하여 휨과 전단에 의한 접합부 불균형모멘트 전달비율에 대한 검토를 하였다.

노인성 우울증 환자에서 수면 장애와 인지기능 저하의 관련성 (Relationship between Sleep Disturbances and Cognitive Impairments in Older Adults with Depression)

  • 이혁주;이정석;김태;윤인영
    • 수면정신생리
    • /
    • 제21권1호
    • /
    • pp.5-13
    • /
    • 2014
  • 목 적: 노인성 우울증에서의 수면장애와 인지기능 저하의 동반은 흔히 나타나는 증상이다. 본 연구의 목적은 지역 사회에 살고 있는 노인 우울증 환자에서 나타나는 수면장애와 인지기능 저하의 양상을 파악하고 수면장애가 인지기능 저하와의 상관관계를 살펴보는 것이다. 방 법: 본 연구의 대상자들은 지역사회에 거주하고 치매 등의 인지기능 장애를 가지고 있지 않으며 수면 및 기분, 인지기능에 영향을 주는 정신과 약물을 복용하고 있지 않은 282명의 65세 이상 노인으로 하였다. 우울증의 평가를 위해 노인성 우울척도(Geriatric depression Scale, GDS)를 평가하였으며 GDS 점수에 따라 10점 미만을 대조군으로 하였고 10점 이상 17점 미만을 경도 우울증군, 17점 이상을 중증도 우울증군으로 분류하였다. 모든 대상자들에게 1회의 야간수면다원검사를 시행하여 객관적인 수면지표를 얻었고 피츠버그 수면의 질 지수(PSQI)를 평가하여 주관적인 수면의 질을 평가하였으며 CERAD-K 신경심리검사를 통하여 인지기능을 평가하였다. 결 과: 연구 대상자들의 평균연령, 성별, 내과적 질환 여부는 세 군 간에 유의한 차이가 없었으나 교육 연한은 대조군에 비해 중증도 우울증군에서 유의하게 낮은 결과를 보였다(p=0.015). 수면다원검사와 피츠버그 수면의 질 지수를 통하여 얻어진 수면지표들 중 REM수면시간, 무호흡-저호흡 지수, 산소 탈포화 지수, PSQI 점수는 세 군 간에 유의한 차이가 있었다(모든 p<0.05). 신경인지기능검사 결과에서는 단어목록재인검사, 스트룹 색깔 및 단어검사, 벤톤 시각 기억 검사-A, 길 만들기 검사-B에서 세 군 간에 통계적으로 유의한 차이가 나타났다(모든 p<0.05). 우울증군에서의 수면장애와 인지기능 저하 간에 상호 인과 관계를 알아보기 위한 Pearson 상관분석과 단계적 다중선형회귀분석 결과 수면장애와 인지기능 저하 간에 상호 관련성은 없는 것으로 나타났다. 결 론: 본 연구에서 노인성 우울증 환자에서 나타나는 수면무호흡증을 제외한 수면장애는 인지기능 저하에 직접적인 영향을 미치지는 않는 것으로 나타났다. 이러한 결과는 노령화에 따른 수면장애 및 수면구조의 변화와 연령, 교육 수준 등의 영향으로 인한 것으로 보인다. 그러나 노인 인구에서의 수면장애의 높은 유병률과 잠재적으로 인지기능에 미칠 수 있는 부정적인 영향력을 고려할 때 후속 연구를 통한 노인성 우울증 환자에서의 수면장애와 인지기능 저하의 상호 관련성에 대한 논의가 요구된다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

온라인 실험을 이용한 카올리나이트 점토의 일차원 압밀 시뮬레이션 (One-Dimensional Consolidation Simulation of Kaolinte using Geotechnical Online Testing Method)

  • 권영철
    • 대한토목학회논문집
    • /
    • 제26권4C호
    • /
    • pp.247-254
    • /
    • 2006
  • 온라인 실험 방법은 실험 정보를 직접 수치 해석에 사용하는 수치 실험법의 하나로, 지반의 역학적 특성이 요소 시험체로 부터 실시간으로 수치해석에 업데이트되므로 이상화된 역학모델을 사용하지 않고 지반 해석을 수행할 수 있다는 장점이 있다. 이 방법은 모래 지반을 주요한 대상으로 하는 지반내진공학 분야에서 주로 사용되어 왔으나 최근 압밀 문제에 적용할 수 있는 실험법이 개발되어 실내 검증과 현장검증이 시도되었다. 지금까지의 관련 연구에서는 압밀층 중앙에 요소 시험체를 위치시켜 평균적인 반응 거동만을 수치해석에 업데이트하는 방법이 주로 사용되어 왔으나, 이러한 경우에는 압밀층 두께가 두꺼워 질수록 해석 정도가 떨어질 수 있다는 점이 단점으로 지적되어 왔다, 따라서 압밀 문제에 대한 온라인 실험법의 유효성 및 가능한 해석 범위를 명확하게 하기 위해서는 이러한 영향요소를 완전히 배제할 수 있는 실험 조건을 적용하여 결과를 검토할 필요가 있다. 따라서, 본 연구에서는 동일한 조건 하에서 실시된 온라인 압밀 시험과 분할형 압밀시험 결과를 이용하여 점토 시료의 압밀 침하와 과잉간극수압 소산 재현 측면에서 온라인 압밀 실험 결과를 검토하였다. 실험결과, 온라인 압밀 실험은 재구성 카올리나이트 점토의 유효 응력에 따른 압축성 변화를 큰 모순 없이 재현해 내고 있었으며, 과잉간극수압 소산 속도 측면에서는 온라인 압밀 실험이 조금 빠른 것을 알 수 있었다. 이러한 실험 결과를 바탕으로 점토 시료의 과잉간극수압 소산 거동을 보다 정도 높게 예측하기 위해서는 점토의 투수성도 리얼타임으로 업데이트 할 수 있는 방향으로 실험 절차가 개선이 되어야 한다는 점과 과잉간극수압 소산 후의 변형에 대해서는 추가적인 연구나 개선이 필요하다는 점을 알 수 있었다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF