• Title/Summary/Keyword: laboratory measurement methods

Search Result 435, Processing Time 0.023 seconds

A Study of Three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer (DLP 프린터로 제작된 레진 임시수복물의 3차원적 정확도 평가)

  • Kang, Wol;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of the DLP 3D printer by conducting 3-dimensional assesment of resin provisional restorations. Methods: The first premolar of the maxillary was prepared for the abutment. The abutment was scanned by using a scanner. The provisional restoration was designed by using CAD software. A total of 16 resin provisional restorations were produced using ZD200 and Veltz DLP 3D printer. Scanning was done of resin provisional restorations and 3-dimensional measurement was conducted for accuracy. The mean (SD) of RMS was reported for each group. Independent t-test was used to assess the statistical significance of the results. All analyses were done using SPSS 22.0. Results: The mean ± SD of RMS value for the accuracy of the resin provisional restorations that was fabricated by using ZD200 and Veltz DLP 3D printer were 50.85.±4.64㎛ and 70.33±6.31㎛. Independent t-test showed significant differences between groups(p<0.001). Conclusion: The resin provisional restorations made with DLP 3D printers showed clinically acceptable accuracy.

Advanced estimation and mitigation strategies: a cumulative approach to enteric methane abatement from ruminants

  • Islam, Mahfuzul;Lee, Sang-Suk
    • Journal of Animal Science and Technology
    • /
    • v.61 no.3
    • /
    • pp.122-137
    • /
    • 2019
  • Methane, one of the important greenhouse gas, has a higher global warming potential than that of carbon dioxide. Agriculture, especially livestock, is considered as the biggest sector in producing anthropogenic methane. Among livestock, ruminants are the highest emitters of enteric methane. Methanogenesis, a continuous process in the rumen, carried out by archaea either with a hydrogenotrophic pathway that converts hydrogen and carbon dioxide to methane or with methylotrophic pathway, which the substrate for methanogenesis is methyl groups. For accurate estimation of methane from ruminants, three methods have been successfully used in various experiments under different environmental conditions such as respiration chamber, sulfur hexafluoride tracer technique, and the automated head-chamber or GreenFeed system. Methane production and emission from ruminants are increasing day by day with an increase of ruminants which help to meet up the nutrient demands of the increasing human population throughout the world. Several mitigation strategies have been taken separately for methane abatement from ruminant productions such as animal intervention, diet selection, dietary feed additives, probiotics, defaunation, supplementation of fats, oils, organic acids, plant secondary metabolites, etc. However, sustainable mitigation strategies are not established yet. A cumulative approach of accurate enteric methane measurement and existing mitigation strategies with more focusing on the biological reduction of methane emission by direct-fed microbials could be the sustainable methane mitigation approaches.

Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath (3D 프린팅용 UV 경화 수지의 조사량 및 항온수조 침적에 따른 수축률의 차이)

  • Kim, Dong-Yeon
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.113-120
    • /
    • 2020
  • Purpose: This study is to compare and analyze the shrinkage of the specimen after UV irradiation of UV cured resin at 5, 15, and 30 minutes. Methods: A cylindrical UV cured specimen was produced using a stainless steel mold. UV cured resin specimens were prepared in three groups: 5 minutes cured (5M), 15 minutes cured (15M), and 30 minutes cured (30M). The measurement was made in total 3rd. The measurement was made in total 3rd. The primary measurement was made after 24 hours using a digital measuring instrument. The 2nd and 3rd measurements were deposited in a constant temperature water bath and the shrinkage was measured. The measured data was calculated by referring to the ASTM C326 linear measurement calculation method. T-test and One-way ANOVA were performed to test the significance between groups. The post-test was conducted with Tukey (α=0.05). Results: When the inner diameter and the outer diameter of the three groups not placed in the water bath were compared and analyzed, the contraction was the smallest at 6.8% in the 5M group, and the contraction was the largest at 7.3% in the 30M group. In the outer diameter, the contraction of the 5M group was the smallest at 3.5%, and the contraction of the 30M group was the largest at 4.5%. Shrinkage decreased in all three groups immersed in a water bath for 3-7 days. Conclusion: In the UV cured resin specimen, the shrinkage increased as the amount of UV irradiation increased.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

Dispersion Behavior and Size Analysis of Thermally Purified High Pressure-high Temperature Synthesized Nanodiamond Particles

  • Kwon, Hansang;Park, Jehong;Leparoux, Marc
    • Journal of Powder Materials
    • /
    • v.24 no.3
    • /
    • pp.216-222
    • /
    • 2017
  • Synthesized monocrystalline nanodiamond (nD) particles are heat-treated at various temperatures to produce highly structured diamond crystals. The heat-treated nDs show different weight loss ratios during thermogravimetric analysis. The crystallinities of the heat-treated nDs are analyzed using Raman spectroscopy. The average particle sizes of the heat-treated nDs are measured by a dynamic light scattering (DLS) system and direct imaging observation methods. Moreover, individual dispersion behaviors of the heat-treated nD particles are investigated based on ultrasonic dispersion methods. The average particle sizes of the dispersed nDs according to the two different measurement methods show very similar size distributions. Thus, it is possible to produce highly crystallized nD powder particles by a heat-treatment process, and the nD particles are relatively easy to disperse individually without any dispersant. The heat-treated nDs can lead to potential applications such as in nanocomposites, quantum dots, and biomedical materials.

Thermography-based coating thickness estimation for steel structures using model-agnostic meta-learning

  • Jun Lee;Soonkyu Hwang;Kiyoung Kim;Hoon Sohn
    • Smart Structures and Systems
    • /
    • v.32 no.2
    • /
    • pp.123-133
    • /
    • 2023
  • This paper proposes a thermography-based coating thickness estimation method for steel structures using model-agnostic meta-learning. In the proposed method, a halogen lamp generates heat energy on the coating surface of a steel structure, and the resulting heat responses are measured using an infrared (IR) camera. The measured heat responses are then analyzed using model-agnostic meta-learning to estimate the coating thickness, which is visualized throughout the inspection surface of the steel structure. Current coating thickness estimation methods rely on point measurement and their inspection area is limited to a single point, whereas the proposed method can inspect a larger area with higher accuracy. In contrast to previous ANN-based methods, which require a large amount of data for training and validation, the proposed method can estimate the coating thickness using only 10- pixel points for each material. In addition, the proposed model has broader applicability than previous methods, allowing it to be applied to various materials after meta-training. The performance of the proposed method was validated using laboratory-scale and field tests with different coating materials; the results demonstrated that the error of the proposed method was less than 5% when estimating coating thicknesses ranging from 40 to 500 ㎛.

Statistical Test of Agreement between Measurements in Method-comparison Study (검사법의 일치도 평가를 위한 분석기법)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.108-112
    • /
    • 2011
  • In clinical settings, researchers often want to assess agreement between two measurements (or tests) of the same continuous variable. For example, when new point-of-care analyzer for testing blood glucose level were introduced clinicians need to compare results from standard or established laboratory method of measurement to those of new or point-of-care analyzer. The question in a method-comparison study would either of two different methods be used to measure the same variable equivalently. In this paper common misuse of statistical methodologies seen in the medical literatures such as correlation coefficient and paired t-test are discussed. The Bland-Altman technique has been widely used for this purpose and provides a graphic in presentation of the findings from a method-comparison study, with a mean value of measurement, this bias and the limits of agreement. For ease of application and interpretation of this technique we discussed the analysis procedure and illustrated with two worked examples. Finally, a number of alternative ways in which data can be analysed and reported in such studies were reviewed.

Clinical Impact and Reliability of Carbonic Anhydrase XII in the Differentiation of Malignant and Tuberculous Pleural Effusions

  • Liu, Yun-Long;Jing, Li-Ling;Guo, Qi-Sen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.351-354
    • /
    • 2013
  • Objective: To assess the practical utility of pleural fluid carbonic anhydrase XII (CAXII) quantification for differential diagnosis of effusions. Materials and Methods: Fluid was collected prospectively from fifty patients presenting with lymphocytic pleural effusions for investigation and CAXII was quantified by ELISA. Results: Pleural fluid CAXII concentrations were significantly higher in lung cancer patients (n=30) than in tuberculous controls (n=20). The sensitivity and specificity of this biomarker were 60%and 75%, respectively. CAXII measurement was not inferior to cytological examination in the diagnosis and exclusion of pleural effusions from lung cancer patitents (sensitivity 60% vs. 57%; specificity 75% vs. 100%; positive predictive value 77%; negative predictive value 54%). In patients with negative cytology, it offered a sensitivity of 54%. Conclusions: Pleural fluid CAXII is elevated in pleural effusions from lung cancer patients. Measurement of CAXII may be used in the future as a valuable adjunct to cytology in the diagnostic assessment of patients with pleural effusions related to lung cancer, especially when cytological examination is inconclusive.

Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy (코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가)

  • Kim, Jae-Hong;Kim, Won-Soo;Kim, Ki-Baek
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.2
    • /
    • pp.361-368
    • /
    • 2013
  • Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

Reasonable Load Characteristic Experiment for Component Load Modeling (개별 부하모델링을 위한 부하의 합리적인 특성실험)

  • Ji, Pyeong-Sik;Lee, Jong-Pil;Im, Jae-Yun;Chu, Jin-Bu;Kim, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • Load modeling is classified into two methods according to approaching method, so called the measurement and component-based method. The measurement method is to model the load characteristics measured directly at substations and feeders. But it is difficult to measure continuously load characteristics from naturally occurring. system variation. The component-based method consists of the fellowing process; component load modeling, composition rate estimation and aggregation of component loads, etc. In this paper, the characteristic experiment of component loads was performed to obtain data for the component load modeling as the component-based method. At first, representative component loads were selected by the proposed method considering the accuracy of load modeling and the performance possibility of component load experiment in the laboratory. Also an algorithm was Proposed to identify the reliability of data obtained from the component load characteristic experiments. In addition, the results were presented as the case studies.