• Title/Summary/Keyword: laboratory measurement methods

Search Result 431, Processing Time 0.027 seconds

Finite Element Analysis of BLDC Motor Characteristic according to Magnetic Property Measurement Methods (자성 측정 방법에 따른 BLDC 전동기의 전자계 특성해석)

  • Kim, Ji-Hyun;Ha, Kyung-Ho;Kwon, Oh-Yeoul;Cha, Sang-Yoon;Kim, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.697-698
    • /
    • 2008
  • This paper deals with finite element characteristic analysis of brushless DC motor according to magnetic property measurement methods. Magnetic property data for non-oriented (NO) electrical steel for electric motors are measured by the Epstein test which is considered as the international standards. Data from Epstein test may result in discrepancy from motor characteristic tests due to innate anisotropic property of NO electrical steel. Finite element analysis were performed for a BLDC motor by various measurement methods such as Epstein test, Ring test and single sheet test (SST), and calculated results were compared with considering anisotropic property conditions.

  • PDF

Comparison of measurement uncertainty calculation methods on example of indirect tensile strength measurement

  • Tutmez, Bulent
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.871-882
    • /
    • 2017
  • Indirect measure of the tensile strength of laboratory samples is an important topic in rock engineering. One of the most important tests, the Brazilian strength test is performed to obtain the tensile strength of rock, concrete and other quasi brittle materials. Because the measurements are provided indirectly and the inspected rock materials may have heterogeneous properties, uncertainty quantification is required for a reliable test evaluation. In addition to the conventional measurement evaluation uncertainty methods recommended by the Guide to the Expression of Uncertainty in Measurement (GUM), such as Taylor's and Monte Carlo Methods, a fuzzy set-based approach is also proposed and resulting uncertainties are discussed. The results showed that when a tensile strength measurement is measured by a laboratory test, its uncertainty can also be expressed by one of the methods presented.

Measurement of Sound Transmission Loss in a Sound Barrier Filled with the Rice-Straw Particles by the Transfer Function and Laboratory Measurement Methods

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sang-Sik;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.338-345
    • /
    • 2018
  • The sound insulation capacity of a barrier is indicated by its transmission loss. In this study, the sound transmission loss of a sound barrier filled with rice-straw particles was measured by the transfer function method and a laboratory measurement method. The results of the two measurements were compared. The transmission losses measured by the two methods were similar above a frequency of 500 Hz. The loss increased greatly upon the introduction of a plywood to the sound barrier. The results of this study are expected to be used to design sound barriers for roads.

A Study on Measurement Uncertainty of Insensitive Munitions Tests (둔감탄약 시험의 측정불확도 산출 방안 연구)

  • Kim, Min;Kim, Jong-Myoung;Yang, Seung-Ho;Sun, Tae-Boo
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.533-547
    • /
    • 2017
  • Purpose: This study proposes the main sources of uncertainty and uncertainty analysis of a measurement system of insensitive munitions tests. Methods: We established the mathematical model for calculating measurement uncertainty of insensitive munitions tests, conducted experiments for calculating uncertainties of dynamic sensitivity and overshoot value, and estimated the distributions of uncertainty factors. Results: The measurement uncertainty calculation methods are presented, which include experimental data processing methods for calculating uncertainties of dynamic sensitivity and overshoot value. Conclusion: The measurement of explosion pressure in insensitive munitions tests is an important issue to the reporting test results and classifying reaction types. The more efforts to ensure the reliability of the insensitive munitions tests results are required.

Analyzing the Influence of Spatial Sampling Rate on Three-dimensional Temperature-field Reconstruction

  • Shenxiang Feng;Xiaojian Hao;Tong Wei;Xiaodong Huang;Pan Pei;Chenyang Xu
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.246-258
    • /
    • 2024
  • In aerospace and energy engineering, the reconstruction of three-dimensional (3D) temperature distributions is crucial. Traditional methods like algebraic iterative reconstruction and filtered back-projection depend on voxel division for resolution. Our algorithm, blending deep learning with computer graphics rendering, converts 2D projections into light rays for uniform sampling, using a fully connected neural network to depict the 3D temperature field. Although effective in capturing internal details, it demands multiple cameras for varied angle projections, increasing cost and computational needs. We assess the impact of camera number on reconstruction accuracy and efficiency, conducting butane-flame simulations with different camera setups (6 to 18 cameras). The results show improved accuracy with more cameras, with 12 cameras achieving optimal computational efficiency (1.263) and low error rates. Verification experiments with 9, 12, and 15 cameras, using thermocouples, confirm that the 12-camera setup as the best, balancing efficiency and accuracy. This offers a feasible, cost-effective solution for real-world applications like engine testing and environmental monitoring, improving accuracy and resource management in temperature measurement.

Comparison of Rock Young's Moduli Determined from Various Measurement Methods (다양한 시험법으로 규명된 암반 탄성계수 비교)

  • Ryu Kuen-Hwan;Chang Chan-Dong
    • The Journal of Engineering Geology
    • /
    • v.16 no.1 s.47
    • /
    • pp.1-14
    • /
    • 2006
  • Various measurements were carried out to estimate the modulus of deformation in two dominant rock types in Korea: granite and gneiss. Four most commonly used methods were utilized: Goodman jack tests, PS well logging, laboratory ultrasonic tests and laboratory uniaxial loading tests. Laboratory static and dynamic Young's moduli depend on the magnitude of the applied axial stress, range of Sequency used for measurement and the loading/unloading condition. As the laboratory measurement condition approaches to that in situ, the resultant moduli also appear to be comparable to that in situ. This suggests that the simulation of in situ stress condition is important when the modulus of rock is determined in the laboratory Dynamic Young's modulus is generally higher than static Young's modulus because of (micro)crack behavior in response to the stress, different range of frequency used for measurements, and the effect of the amplitude of deformation. Understanding of the relations in moduli from different measurement methods will help estimate appropriate in situ values.

Precision Current Measurement of Magnet Power Supply at the PLS-II (포항가속기연구소 전자석전원장치 출력 전류 정밀 측정)

  • Kim, Sung-chul;An, Suk-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.67-68
    • /
    • 2016
  • The accurate measurement of magnet power supplies (MPS) output currents is essential to delivering stable and repeatable currents to magnets in particle accelerators. An essential element in guaranteeing and evaluating the required performance is the current measurement device and methode. In this paper, we discuss instrument and methods for precision current measurement and performance of the PLS-II MPS.

  • PDF

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

GPS phase measurement cycle-slip detection based on a new wavelet function

  • Zuoya, Zheng;Xiushan, Lu;Xinzhou, Wang;Chuanfa, Chen
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.91-96
    • /
    • 2006
  • Presently, cycle-slip detection is done between adjacent two points in many cycle-slip methods. Inherently, it is simple wavelet analysis. A new idea is put forward that the number of difference point can adjust by a parameter factor; we study this method to smooth raw data and detect cycle-slip with wavelet analysis. Taking CHAMP satellite data for example, we get some significant conclusions. It is showed that it is valid to detect cycle-slip in GPS phase measurement based on this wavelet function, and it is helpful to improve the precision of GPS data pre-processing and positioning.

  • PDF