• Title/Summary/Keyword: laboratory measurement

Search Result 1,944, Processing Time 0.031 seconds

Data Reduction and Analysis of the Resonant Column Testing Based on the Equation of Motion (운동방정식에 기초한 공진주 실험의 자료분석 및 해석)

  • 조성호;강태호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.133-144
    • /
    • 2003
  • The resonant column testing is a laboratory testing method to determine the shear modulus and material damping factor of soils. The method has been widely used for many applications and its importance has increased. Since the first use of the testing method in 1960's, the low-technology electronic devices fir testing and data acquisition have limited the measurement only to the amplitude of the linear spectrum. The limitations of the testing method are also attributed to the assumption of linear-elastic material in the theory of the resonant column testing and also to the incomplete understanding of the dynamic behaviour of the resonant column testing device. Recently, Joh et al. proposed a theory to overcome the limitations of the resonant column testing by deriving the equation of motion and providing its solution for the resonant column testing device. This study proposed the improved data reduction and analysis method for the resonant column testing, thanks to the advanced data acquisition system and the new theoretical solution for the resonant column testing system. For the verification of the proposed data reduction and analysis method, the numerical simulation of the resonant column testing was performed by the finite element analysis. Also, a series of resonant column testing were performed fir Joomunjin sand, which verified the feasibility of the proposed method and revealed the limitations of the conventional data reduction and analysis method.

Development of a self-leveling system for the bucket of an agricultural front-end loader using an electro hydraulic proportional valve and a tilt sensor (전자유압 비례밸브와 경사센서를 이용한 농용 프론트 로더 버켓 능동수평유지 시스템 개발)

  • Lee, Chang Joo;Ha, Jong Woo;Choi, Deok Su;Kim, Hak Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.60-70
    • /
    • 2015
  • A front-end loader (FEL) mounted on an agricultural tractor is one of the most commonly used implements for farm work. However, when the tractor carries material using the bucket attached to the FEL on a sloping ground, the materials can spill or roll back over the operator due to the tilted body, thereby requiring the bucket surface to remain level at a constant value regardless of varying slopes. In this study, an active system for controlling the angle of the FEL bucket on a tractor based on the real-time measurement of ground slopes was developed to enable the bucket to constantly remain level. A FEL simulator operated based on an electro hydraulic proportional valve (EHPV) was constructed in the laboratory to develop a proportional-integral-derivative (PID) controller forming a virtual electronic control unit (ECU) on the computer, which could automatically adjust the bucket angles depending on varying input angles while sending SAE-J1939 associated messages via CAN BUS to the EHPV. The different parameter values for the PID controller due to the gravity effect of the bucket were determined using a manual PID tuning method while assuming that the tractor travels on either an ascending slope or a descending slope. The developed PID control-based self-leveling system showed a mean of steady-state errors of within $1^{\circ}$ and a mean of delayed times of ~ 0.8s when the step input of $+20^{\circ}$ was given, implying that the developed system and control algorithm would be effective in maintaining the bucket angle at a certain value. Future studies include the improvement of the control algorithm to reduce such a time delay as well as the application of the developed algorithm to the FEL mounted on a tractor tested at a testing ground.

Acute toxicity of lambda-cyhalothrin to Chironomus riparius in water alone and sediment-water systems (저니토독성시험법(sediment toxicity test)을 이용한 lambda-cyhalothrin의 깔따구 (Chironomus riparius)에 대한 급성독성)

  • Kim, Byung-Seok;Hamer, M.J.;Kim, Jin-Hwa;Park, Yoen-Ki;Kim, Jeong-Gu;Ahn, Young-Joon
    • The Korean Journal of Pesticide Science
    • /
    • v.3 no.1
    • /
    • pp.57-65
    • /
    • 1999
  • The midge Chironomus riparius is a member of widespread dipteran insect which has been used for sediment toxicity test. The 2nd-3rd larvae Chironomus riparius were exposed to $^{14}C$-lambda-cyhalothrin in laboratory water only system(A) and sediment-water system(B) at $20{\pm}2^{\circ}C$. The concentration was nominally in the range of 0.16 to $20{\mu}g/{\ell}$ and 62.5 to 8000 ${\mu}g/kg$, respectively. System(A) was prepared by applying the chemical to 250 ml water and introducing Chironomus riparius larvae into the system(day 0). System(B) was prepared by applying the chemical to the 25 g of soil and 250 ml water and shaking and rolling them for two hours. After allowing the system to settle for two days, Chironomus riparius larvae were introduced into the system. After 72 hours, the two systems were terminated and dead larvae were observed. The measurement of residue in water was conducted at the start(day 0) and the end of the study(day 3). The residue of $^{14}C$-lambda-cyhalothrin in water was accounted for approximately 65% of nominal concentration in system(A) and $0.2{\sim}0.4%$ in system) on 3 days. $LC_{50}$ was less than $0.156{\mu}g/{\ell}$ in system(A) and 889 ${\mu}g/kg$ in system(B), based on the nominally applied concentration.

  • PDF

SIMULTANEOUS OBSERVATIONS OF PI 2 PULSATIONS ON THE SATELLITE AND GROUND-BASED MEASUREMENTS (위성 및 지상자력계에서의 PI 2 파동 동시 관측)

  • 이성환;이동훈;김관혁
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.275-285
    • /
    • 1997
  • We have investigated Pi 2 pulsations which were observed both on ground magnetometer array and by satellites. On November 9th in 1994, Pi 2 pulsations appeared globally on the 190/210 magnetometer chain and Hermanus station when two satellites(EXOS-D and ETS-VI) were located near the magnetic meridian of the 210 array. The local time of measurements covers from morning(LT=8.47hr) to afternoon(LT=20.3hr) and the bandwidth of peak frequency is found relatively small. The signals of the electric field are highly coherent with ground-based observations with the out of phase oscillations. However, the magnetic field measurement on the ETS-VI in the outer magnetosphere(L=6.60) shows no signature of Pi 2 pulsations over the same time interval and the correlation with any of the ground-based stations is found to be very weak, even through both satellites and magnetometer chain are located close to each other in local time. We suggest that this event may be a direct evidence of Pi 2 pulsations as virtual resonant modes which are localized in the plasmasphere(Lee 1996). The results show that the cavity mode oscillations can occur in the inner magnetosphere with less spectral noise compared to the outer magnetospheric case.

  • PDF

DEVELOPMENT OF A FLUXGATE MAGNETOMETER FOR THE KITSAT-3 SATELLITE (과학위성용 자력계 탑재체 개발에 관한 연구)

  • ;;;;;;Onishi Nobugito
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.312-319
    • /
    • 1997
  • The magnetometer is one of the most important payloads for scientific satellite to monitor the near-earth space environment. The electromagnetic variations of the space environment can be observed with the electric and magnetic field measurements. In practice, it is well known that the measurement of magnetic fields needs less technical complexities than that of electric fields in space. Therefore the magnetometer has long been recognized as one of the basic payloads for the scientific satellites. In this paper, we discuss the scientific fluxgate magnetometer which will be on board the KITSAT-3. The main circuit design of the present magnetometer is based on that of KITSAT-1 and -2 but its facilities have been re-designed to improve the resolution to about 5nT for scientific purpose. The calibration and noise level test of this circuit have been performed at the laboratory of the Tierra Tecnica company in Japan.

  • PDF

Comparative efficacy of silver containing dressing materials to Staphylococcus aureus and Pseudomonas aeruginosa on infected full thickness skin wound in the rat (흰쥐의 감염된 전층피부결손에서 은 함유 드레싱제제의 Staphylococcus aureus 및 Pseudomonas aeruginosa 균주에 대한 효과의 비교)

  • Lee, Jong Hoon;Kim, Dong Gu;Lee, Won Mi;Chae, Jeong Don
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.372-379
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the effect on antibacterial activities and wound healing effect of silver containing dressings with which of Betadine against Staphylococcus aureus and Pseudomonas aeruginosa. Methods: One full thickness skin defects in rats(n=72) were developed on the back and were given rise to infection with S. aureus(n=36) and P. aeruginosa(n=36). The 72 mice were divided into 6 groups : Acticoat$^{(R)}$, Aquacel$^{(R)}$-Ag, Medifoam silver$^{(R)}$, Polymen silver$^{(R)}$, Ilvadon$^{(R)}$ and Betadine(control group) dressing groups. Five silver containing dressings and Betadine were assesed on infected wound. Measurement of wound size change, bacterial colonies count and histologic findings was applied. Antibacterial activity was analyzed with bacterial restricted zone in Mueller Hinton agar. Results: On S. aureus, wound size was more decreased in all treated groups as compared with betadine, however Ilvadon$^{(R)}$ was less decreased on P. aeruginosa. In histologic findings, experimental group showed more effective findings than others on S. aureus, however on P. aeruginosa, which was showed similar. Acticoat$^{(R)}$ was best effective in wound healing against S. aureus and P. aeruginosa. The bacterial colonies count was increased in all treated groups except Acticoat$^{(R)}$ as compared with the control group on S. aureus, which was decreased in Acticoat$^{(R)}$ and Ilvadon$^{(R)}$ group on P. aeruginosa. There were not statistical differences. The restricted zone was shown in Mueller - Hinton agar of all groups except Medifoam silver$^{(R)}$ group on S. aureus, which was shown of all groups on P. aeruginosa. There were statistical differences. Conclusion: This study suggests that silver containing dressings may have not better potential than Betadine in assisting management of wounds at risk of infection on S. aureus and P. aeruginosa. However, which have better antibacterial activity on S. aureus and P. aeruginosa.

On the Evaluation of Construction Standards Based on Seismic Velocities Obtained In-Situ and through Laboratory Rock Tests (현장 및 실내 측정 탄성파 속도에 근거한 암반평가 기준에 대한 고찰)

  • Lee, Kang Nyeong;Park, Yeon Jun
    • Tunnel and Underground Space
    • /
    • v.27 no.4
    • /
    • pp.230-242
    • /
    • 2017
  • Seismic velocities measured from in-situ tests (n=177) and through rock core samples (n=1,035) are reviewed in light of construction standards, widely used standards as a first-hand approximation of rock classification solely based on seismic velocities. In-situ down hole tests and refraction survey for soft rocks showed seismic velocities of 1,400~2,900 m/s which is faster than those specified in construction standards. For moderate~ hard rocks, in-situ down hole tests and refraction survey showed 2,300~3,800 m/s which roughly corresponds with the range specified in the construction standards. A similar trend is also observed for seismic velocities measured from rock core samples. The observed differences between construction standards and seismic velocities can be explained in two ways. If construction standards are correct the observed differences may be explained with seismic velocities affected by underlying fast velocities and also possibly with selection of intact cores for velocity measurement. Alternatively, construction standards may have intrinsic problems, namely artificial discrete boundaries between soft rocks and moderate rocks, application of foreign standards without consideration of geologic setting and lack of independent verification steps. Therefore, we suggest a carefully designed verification studies from a test site. We also suggest that care must be exercised when applying construction standards for the interpretation and accessment of rock mass properties.

Micro/Nanotribology and Its Applications

  • Bhushan, Bharat
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.128-135
    • /
    • 1995
  • Atomic force microscopy/friction force microscopy (AFM/FFM) techniques are increasingly used for tribological studies of engineering surfaces at scales, ranging from atomic and molecular to microscales. These techniques have been used to study surface roughness, adhesion, friction, scratching/wear, indentation, detection of material transfer, and boundary lubrication and for nanofabrication/nanomachining purposes. Micro/nanotribological studies of single-crystal silicon, natural diamond, magnetic media (magnetic tapes and disks) and magnetic heads have been conducted. Commonly measured roughness parameters are found to be scale dependent, requiring the need of scale-independent fractal parameters to characterize surface roughness. Measurements of atomic-scale friction of a freshly-cleaved highly-oriented pyrolytic graphite exhibited the same periodicity as that of corresponding topography. However, the peaks in friction and those in corresponding topography were displaced relative to each other. Variations in atomic-scale friction and the observed displacement has been explained by the variations in interatomic forces in the normal and lateral directions. Local variation in microscale friction is found to correspond to the local slope suggesting that a ratchet mechanism is responsible for this variation. Directionality in the friction is observed on both micro- and macro scales which results from the surface preparation and anisotropy in surface roughness. Microscale friction is generally found to be smaller than the macrofriction as there is less ploughing contribution in microscale measurements. Microscale friction is load dependent and friction values increase with an increase in the normal load approaching to the macrofriction at contact stresses higher than the hardness of the softer material. Wear rate for single-crystal silicon is approximately constant for various loads and test durations. However, for magnetic disks with a multilayered thin-film structure, the wear of the diamond like carbon overcoat is catastrophic. Breakdown of thin films can be detected with AFM. Evolution of the wear has also been studied using AFM. Wear is found to be initiated at nono scratches. AFM has been modified to obtain load-displacement curves and for nanoindentation hardness measurements with depth of indentation as low as 1 mm. Scratching and indentation on nanoscales are the powerful ways to screen for adhesion and resistance to deformation of ultrathin fdms. Detection of material transfer on a nanoscale is possible with AFM. Boundary lubrication studies and measurement of lubricant-film thichness with a lateral resolution on a nanoscale have been conducted using AFM. Self-assembled monolyers and chemically-bonded lubricant films with a mobile fraction are superior in wear resistance. Finally, AFM has also shown to be useful for nanofabrication/nanomachining. Friction and wear on micro-and nanoscales have been found to be generally smaller compared to that at macroscales. Therefore, micro/nanotribological studies may help def'me the regimes for ultra-low friction and near zero wear.

Development of a Simple In-Situ Data Logger (간단한 현장 데이타 수집장치의 개발에 관한 연구)

  • Yeo, Woo-Kwang;Yoon, Byung-Man;Lee, Jong-Kuk
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.249-260
    • /
    • 1996
  • There have been easily found a number of examples that misleading or unreasonable measuring data set of physical variables are often produced in the field and the laboratory. The primary reason is that the specific requirements of civil engineers are initially disregarded in designing the experimental apparatus. It results from a lack of mutual understanding and co-operating between the user group and the maker. Therefore, their fundamental knowledge and apprehension become indispensible in order to obtain measuring data with high confidence and good quality In this study it is shortly explained the basic structure and the operation system of the experimental equipments commonly used at the present. A simple measuring set is developed which is quite easy for a general civil engineer to design and operate without any other specialty of mostly electricity electronics. Based upon this requirement, one of data logger named PPDL8 is newly designed by making use of the parallel port in the personal computer, consisting of multi-channels able to measure 8 different point values simultaneously. It can also use many valuable sub-programs existing in PC because the user makes his own programs necessary for measurement, by himself. Of all things, it has a great advantage to increase the applicability of field measurements much larger when adopting the notebook computer to operate with small battery only. In addition this study gives, in fact, the excellent agreements of in-situ field variables by showing their measuring results of temperature, distance and turbidity.

  • PDF

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF