• Title/Summary/Keyword: laboratory markers

Search Result 512, Processing Time 0.028 seconds

Development of Underwater Motion Measurement System for Model Test of Ocean System (해양시스템 모형실험을 위한 수중운동계측시스템 개발 연구)

  • CHOI JONG-SU;HONG SUP
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.166-172
    • /
    • 2004
  • An underwater motion measurement system was constructed for applications to the model basin. A commercial motion capture system, FALCON of Motion Analysis Corp., which corrects automatically the distortion caused by refraction of the light passing through water and air, was adopted for underwater motion measurement. The modifications of FALCON system were performed: waterproofing camera housings, markers, connectors, and a new blue ring lighter. the accuracy of the motion measurement was obtained within the calibration error of 0.87mm in average and 0.89mm in standard deviation for the distance of 500mm between two markers on the calibration device. the volume of $2100mm(length)\times2100mm(breadth)\times2300mm(Height)$ was covered with 4 cameras of the underwater motion measurement system. For the performance verification, motion measurement test of a vertical mooring chain model excited at the top end was carried out. The 3D motions of mooring model were measured with variable amplitude and period of the forced excitation. Higher order motions of the mooring model were observed as the excitation period decreases. the performance of the system was verified by successfully measuring 3D motion of mooring model.

  • PDF

Analysis of Biochemical Markers in Sera of Patients with Febrile Disease During the Fall

  • Kim, Chong-Ho;Park, Seung-Taeck;Seo, Young-Mi
    • Biomedical Science Letters
    • /
    • v.16 no.4
    • /
    • pp.311-316
    • /
    • 2010
  • We studied a comparison of the concentration of biochemical markers in sera of patients hospitalized with high fever (n=296) in Jeonbuk province during the last 2 years (2008 to 2009). The patients were divided into three patient groups of viral hemorrhagic fever (VHF) patient group tested positive for Hantavirus (n=53), leptospirosis (LEP) patient group tested positive for Leptospira interrogans (n=137) and scrub typhus (TSU) patient group tested positive for Orientia tsutsugamushi (n=106). We analyzed the concentration of ALP, AST, ALT, blood urea nitrogen, creatinine and glucose and compared the mean levels of them to normal range, the first sample and last sample. The frequencies of abnormal patient elevated above the upper limit of normal for ALP, AST and ALT were 18~43.4%, 78~97% and 62.3~92.7% in patient groups, and 24.5~47.4% (total protein) and 13.2~50.0% (albumin) of patients in patient groups had decreased below the lower limit of normal. The patients showed higher abnormal levels of glucose in patient groups were 58.5% (viral hemorrhagic fever patient group), 66.4% (leptospirosis patient group), 71.7% (scrub typhus patient group) and 66.9% (total patient group). There were significant difference between the first sample and the last sample in the mean levels of AST (decreased 22.2% in viral hemorrhagic fever patient group, 30.2% in leptospirosis patient group, 20.4% in scrub typhus patient group and 24.1% in total patient group), BUN (43.0% in viral hemorrhagic fever patient group, 41.6% in leptospirosis patient group, 47.4% in scrub typhus patient group and 43.0% in total patient group) and glucose (20.2% viral hemorrhagic fever patient group, 17.9% in leptospirosis patient group, 18.6% in scrub typhus patient group and 18.9% in total patient group) in the first sample and the last sample. According to these results, those diseases may cause liver damage and have high concentration of ALP, AST, ALT and glucose in blood even though the patients get out of the hospital.

Value of Combined Detection of Serum CEA, CA72-4, CA19-9 and TSGF in the Diagnosis of Gastric Cancer

  • Yin, Li-Kui;Sun, Xue-Qing;Mou, Dong-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3867-3870
    • /
    • 2015
  • Background: To explore whether combined detection of serum tumor markers (CEA, CA72-4, CA19-9 and TSGF) improve the sensitivity and accuracy in the diagnosis of gastric cancer (GC). Materials and Methods: An automatic chemiluminescence immune analyzer with matched kits were used to determine the levels of serum CEA, CA72-4, CA19-9 and TSGF in 45 patients with gastric cancer (GC group), 40 patients with gastric benign diseases (GBD group) hospitalized in the same period and 30 healthy people undergoing a physical examination. The values of those 4 tumor markers in the diagnosis of gastric cancer was analyzed. Results: The levels of serum CEA, CA72-4, CA19-9 and TSGF of the GC group were higher than those of the GBD group and healthy examined people and the differences were significant (P<0.001). The area under receiver operating characteristic (ROC) curves for single detection of CEA, CA72-4, CA19-9 and TSGF in the diagnosis of GC was 0.833, 0.805, 0.810 and 0.839, respectively. The optimal cutoff values for these 4 indices were 2.36 ng/mL, 3.06 U/mL, 5.72 U/mL and 60.7 U/mL, respectively. With combined detection of tumor markers, the diagnostic power of those 4 indices was best, with an area under the ROC curve of 0.913 (95%CI 0.866~0.985), a sensitivity of 88.9% and a diagnostic accuracy of 90.4%. Conclusions: Combined detection of serum CEA, CA72-4, CA19-9 and TSGF increases the sensitivity and accuracy in diagnosis of GC, so it can be regarded as the important means for early diagnosis.

Prediction Model for the Cellular Immortalization and Transformation Potentials of Cell Substrates

  • Lee, Min-Su;Matthews Clayton A.;Chae Min-Ju;Choi, Jung-Yun;Sohn Yeo-Won;Kim, Min-Jung;Lee, Su-Jae;Park, Woong-Yang
    • Genomics & Informatics
    • /
    • v.4 no.4
    • /
    • pp.161-166
    • /
    • 2006
  • The establishment of DNA microarray technology has enabled high-throughput analysis and molecular profiling of various types of cancers. By using the gene expression data from microarray analysis we are able to investigate diagnostic applications at the molecular level. The most important step in the application of microarray technology to cancer diagnostics is the selection of specific markers from gene expression profiles. In order to select markers of Immortalization and transformation we used c-myc and $H-ras^{V12}$ oncogene-transfected NIH3T3 cells as our model system. We have identified 8751 differentially expressed genes in the immortalization/transformation model by multivariate permutation F-test (95% confidence, FDR<0.01). Using the support vector machine algorithm, we selected 13 discriminative genes which could be used to predict immortalization and transformation with perfect accuracy. We assayed $H-ras^{V12}$-transfected 'transformed' cells to validate our immortalization/transformation dassification system. The selected molecular markers generated valuable additional information for tumor diagnosis, prognosis and therapy development.

Determining the Required Vitamin D Level for Bone Health Based on Bone Turnover Markers

  • Ismail, Tuan Salwani Tuan;Muda, Bayani Che;Rosdi, Roznie Aida Mohd;Zainuddin, Azalina;Isa, Salbiah;Mustapaha, Zulkarnain
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.337-344
    • /
    • 2017
  • To date, no clear threshold that has been established for defining an adequate store of vitamin D for bone health. Therefore, this study aims to determine the required level of vitamin D to maintain a healthy skeleton based on bone remodelling process among healthy adult population. This was a cross sectional study, involving a healthy adult population in Kota Bharu, Malaysia, aged 18~50 years. We measured serum 25(OH)D (vitamin D), serum parathyroid hormone (PTH), serum C-terminal telopeptide of type 1 collagen (CTX), and Procollagen 1 Intact N-Terminal (P1NP) in 120 healthy adults selected via multi stage sampling (64 males, 56 females) from 6 subdistricts in Kota Bharu. The mean level of 25(OH)D was 23.50 (${\pm}8.74$) nmol/L. There was a significant difference of the vitamin D level between genders ($26.81{\pm}8.3nmol/L$ vs $19.72{\pm}7.68nmol/L$ in males and females respectively) (p value<0.001). More than 50% of female subjects had 25(OH)D less than 20 nmol/L, while only 20.3% of male subjects had 25(OH)D below 20 nmol/L. Based on the LOESS plot, the bone turnover markers showed a plateauing result, at the 25(OH)D level of 35 nmol/L for CTX and 20 nmol/L for P1NP. Contrastingly, PTH showed a step rise in the 25(OH)D level of 20 nmol/L. Based on the LOESS plot for CTX, P1NP and PTH versus 25(OH)D, level of vitamin D between 20 to 35 nmol/L is recommended to maintain healthy skeleton.

A Case Report of Metastatic Breast Cancer Patient Treated with Integrative Cancer Treatment (전이성 유방암 환자의 통합 암 치료에 대한 증례보고)

  • Ha, Su-jeong;Lee, Sung-cheol;Park, So-jung;Jeon, Hyung-joon;Lee, Yeon-Weol;Cho, Chong-kwan;Yoo, Hwa-seung
    • Journal of Korean Traditional Oncology
    • /
    • v.24 no.1
    • /
    • pp.19-28
    • /
    • 2019
  • Objective : The purpose of this study is to report and observe effects of Integrative Cancer Treatment (ICT) on metastatic breast cancer patient. Method : A left breast cancer patient diagnosed with recurrence on liver and bones April 2018. The patient had received paclitaxel chemotherapy for two months and discontinued it because of tumor progression and side effects. The patient has been treated with ICT since March 2018 and has been taking capecitabine since October 2018. The clinical outcomes were measured by computed tomography, laboratory findings including tumor markers (CEA, CA15-3). The clinical outcomes were measured by computed tomography, laboratory findings including tumor markers (CEA, CA15-3), liver function test (AST, ALT), Eastern Cooperative Oncology Group performance status (ECOG PS), and numeric rating scales (NRS). Results : After the ICT, tumor size was partially decreased accompanying by reducing the levels of tumor markers. Major clinical symptoms induced by paclitaxel chemotherapy were improved. There were no severe adverse events induced by ICT based on National Cancer Institute Common Terminology Criteria for Adverse Events (NCI CTCAE) version 5.0. Conclusion : This case suggests that ICT may have synergistic effect for the treatment of metastatic breast cancer patient in conjunction with capecitabine.

Molecular Marker Development for the Rapid Differentiation of Black Rot Causing Xanthomonas campestris pv. campestris Race 7

  • Yeo-Hyeon Kim;Sopheap Mao;Nihar Sahu;Uzzal Somaddar;Hoy-Taek Kim;Masao Watanabe;Jong-In Park
    • The Plant Pathology Journal
    • /
    • v.39 no.5
    • /
    • pp.494-503
    • /
    • 2023
  • Xanthomonas campestris pv. campestris (Xcc) is a plant pathogen of Brassica crops that causes black rot disease throughout the world. At present, 11 physiological races of Xcc (races 1-11) have been reported. The conventional method of using differential cultivars for Xcc race detection is not accurate and it is laborious and time-consuming. Therefore, the development of specific molecular markers has been used as a substitute tool because it offers an accurate and reliable result, particularly a quick diagnosis of Xcc races. Previously, our laboratory has successfully developed race-specific molecular markers for Xcc races 1-6. In this study, specific molecular markers to identify Xcc race 7 have been developed. In the course of study, whole genome sequences of several Xcc races, X. campestris pv. incanae, X. campestris pv. raphani, and X. campestris pv. vesicatoria were aligned to identify variable regions like sequence-characterized amplified regions and insertions and deletions specific to race 7. Primer pairs were designed targeting these regions and validated against 22 samples. The polymerase chain reaction analysis revealed that three primer pairs specifically amplified the DNA fragment corresponding to race 7. The obtained finding clearly demonstrates the efficiency of the newly developed markers in accurately detecting Xcc race 7 among the other races. These results indicated that the newly developed marker can successfully and rapidly detect Xcc race 7 from other races. This study represents the first report on the successful development of specific molecular markers for Xcc race 7.

Assessment of genetic diversity among wild and captive-bred Labeo rohita through microsatellite markers and mitochondrial DNA

  • Muhammad Noorullah;Amina Zuberi;Muhib Zaman;Waqar Younas;Sadam Hussain;Muhammad Kamran
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.12
    • /
    • pp.752-761
    • /
    • 2023
  • Genetic diversity serves as the basis for selecting and genetically enhancing any culturable species in aquaculture. Here, two different strains of wild (River Ravi and River Kabul) and six captive-bred strains of Labeo rohita from various provinces were se- lected, and genetic diversity among them was evaluated using three different microsatellite markers, i.e., Lr-28, Lr-29, and Lr-37, and one mitochondrial CO1 (Cytochrome c oxidase subunit 1) gene. Different strains of L. rohita were collected, and part of their caudal fin was cut and preserved in ethanol for DNA extraction and determination of genetic diversity among them. Results in- dicated that selected markers were polymorphic with polymorphic information content (PIC) content values above 0.5 with the highest in Lr-28 followed by Lr-29 and then Lr-37. The observed heterozygosity (Ho) of all strains was higher (Avg: 0.731) but less than the expected heterozygosity (He). Moreover, TMs and WRs showed the highest He, while TKs showed the lowest, He. Over- all, inbreeding coefficient (FIS) values observed for all strains with selected markers were positive. The DNA barcoding with the CO1 gene revealed genetic variation among various strains, as demonstrated by the clades in the phylogenetic tree separating the strains into two distinct clusters that then divided into sub-clusters. In conclusion, TMs showed the highest heterozygosity as compared to other strains. Overall results provide the baseline data for the initiation of the genetic improvement program.

Genetic Variability in the Natural Populations of Daba Ecorace of Tasar Silkworm (Antheraea mylitta Drury), as Revealed by ISSR Markers

  • Mohandas, T.P.;Vijayan, K.;Kar, P.K.;Awasthi, A.K.;Saratchandra, B.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.2
    • /
    • pp.211-215
    • /
    • 2004
  • Genetic diversity within the natural populations of Daba ecorace of Antheraea mylitta Drury was studied using individual silkworms collected from the South Singhbhum district of Jharkhand state of India with 21 inter simple sequence repeat (ISSR) primers. A total of 148 bands were produced, of which 79% was polymorphic. The pair wise genetic distance among the individuals varied from 0.186 to 0.329. The dendrogram grouped the individuals into 3 major clusters. Nei's heterozygosity analysis revealed 0.265 ${\times}$ 0.18 variability within the population. The high genetic variability present within the natural population of Daba ecorace of A. mylitta is indicative of their adaptational strategy in nature and have much importance for in situ conservation as well as utilization in breeding programs.

A Case Report of HBsAg Seroclearance in Chronic Hepatitis B Patient

  • Lee, Hyeok Jae;Lee, Min-Hyeok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.142-146
    • /
    • 2012
  • Hepatitis B surface antigen (HBsAg) seroclearance is a rare event in chronic hepatitis B virus (HBV) infection which acquires the disease early in life. A case study have examined with asymptomatic chronic hepatitis B carrier who exhibits HBsAg seroclearance in anti-HBe positive. We comprehensively studied the biochemical, virological and clinical aspects of a patient with HBsAg seroclearance. Liver biochemistry, serological markers, serum HBV DNA levels, and development of clinical complications were monitored. Mutation of hepatitis B virus is suspected serum HBsAg detected by the HBsAg assay systems of VITROS (OrthoClinical Diagnostics, USA), AxSYM (Abbott Laboratories, USA), Elecsys (Roche Diagnostics, Germany) and ADVIA Centaur (Bayer Diagnostics, USA). These four immunoassays showed negative results. Also, the patient had undetectable serum HBV DNA. Therefore, no mutation within the "a" determinant of HBsAg, which might escape detection from HBsAg immunoassay were found. Natural seroclearance was confirmed.

  • PDF