• Title/Summary/Keyword: l/f Noise

Search Result 62, Processing Time 0.027 seconds

Analysis and Optimization of the CMOS Transistors for RF Applications with Various Channel Width and Length (CMOS 트랜지스터의 채널 폭 및 길이 변화에 따른 RF 특성분석 및 최적화)

  • Choi, Jeong-Ki;Lee, Sang-Gug;Song, Won-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.9-16
    • /
    • 2000
  • MOS transistors are fabricated and evaluated for RF IC applications such as mobile communication systems using 0.35m CMOS process. Characteristics of MOSFETs are analyzed at various channel length, width and bias conditions. From the analysis, cut-off frequency ($f_T$) is independent on channel width but maximum oscillation frequency ($f_{max}$) tends to derease as the channel width increases. As channel length increases, $f_T$ and fmax decrease. $f_T$ is 22GHz and fmax is 28GHz at its maximum value. High frequency noise performance is improved with larger channel width and smaller channel length at same bias conditions. NFmin at 2GHz is 0.45dB as a minimum value. From the evaluation, MOSFETs designed using 0.35m CMOS process demonstrated a full potential for the commercial RF ICs for mobile communication systems near 2GHz. And optimization methods of the CMOS transistors for RF applications are presented in this paper.

  • PDF

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

Optimum Design of an Indoor Package Air-Conditioner's Flow Path by Taguchi Method (다구찌 방법에 의한 PAC 실내기 유로의 최적설계)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 2014
  • In this study, the optimum design process of an indoor package air-conditioner (PAC) was implemented by Taguchi method. The goal of this study is to obtain the best set condition of each control factor composing of an indoor PAC. The number of revolution of a double inlet sirocco fan installed in an indoor PAC was measured by the orthogonal array of $L_{18}(2^3{\times}3^4)$ and analysed by using the-smaller- the-better characteristic among the static characteristic analyses. As a result, the optimum condition of an indoor PAC was found as a set of when the cost of production, assembling and working conditions were considered. Moreover, the number of revolution of a double-inlet sirocco fan used for an optimum condition was reduced about 8.5% more than that of a standard condition for the target flowrate of $18.5m^3/min$.

Korean ESL Learners' Perception of English Segments: a Cochlear Implant Simulation Study (인공와우 시뮬레이션에서 나타난 건청인 영어학습자의 영어 말소리 지각)

  • Yim, Ae-Ri;Kim, Dahee;Rhee, Seok-Chae
    • Phonetics and Speech Sciences
    • /
    • v.6 no.3
    • /
    • pp.91-99
    • /
    • 2014
  • Although it is well documented that patients with cochlear implant experience hearing difficulties when processing their first language, very little is known whether or not and to what extent cochlear implant patients recognize segments in a second language. This preliminary study examines how Korean learners of English identify English segments in a normal hearing and cochlear implant simulation conditions. Participants heard English vowels and consonants in the following three conditions: normal hearing condition, 12-channel noise vocoding with 0mm spectral shift, and 12-channel noise vocoding with 3mm spectral shift. Results confirmed that nonnative listeners could also retrieve spectral information from vocoded speech signal, as they recognized vowel features fairly accurately despite the vocoding. In contrast, the intelligibility of manner and place features of consonants was significantly decreased by vocoding. In addition, we found that spectral shift affected listeners' vowel recognition, probably because information regarding F1 is diminished by spectral shifting. Results suggest that patients with cochlear implant and normal hearing second language learners would experience different patterns of listening errors when processing their second language(s).

Design of Quadrature CMOS VCO using Source Degeneration Resistor (소스 궤환 저항을 이용한 직교 신호 발생 CMOS 전압제어 발진기 설계)

  • Moon Seong-Mo;Lee Moon-Que;Kim Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.12 s.91
    • /
    • pp.1184-1189
    • /
    • 2004
  • A new schematic of quadrature voltage controlled oscillator(QVCO) is designed and fabricated. To obtain quadrature characteristic and low phase noise simultaneously, two differential VCOs are forced to un in quadrature mode by using coupling amplifier with a source degeneration resistor, which is optimized to obtain quadrature accuracy with minimum phase noise degradation. The designed QVCO was fabricated in standard CMOS technology. The measured performance showed the phase noise of below -120 dBc/Hz at 1 MHEz frequency offset, tuning bandwidth of 210 MHz from 2.34 GHz to 2.55 GHz with a tuning voltage varying form 0 to 1.8 V Quadrature error of 0.5 degree and amplitude error of 0.2 dB was measured with conjunction with low-lF mixer. The fabricated QVCO requires 19 mA including 5 mA in the VCO core part fiom a 1.8 V supply.

Performance of Radio Communication DS/CDMA System with Diversity Technique and BCH Coding under Impulsive Noise and Nakagami Fading (임펄스 잡음과 나카가미 페이딩이 존재할 때 다이버시티 기법과 오류정정 부호를 이용한 무선통신 DS/CDMA 시스템의 오율 특성)

  • 김지웅;강희조;이권현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.4
    • /
    • pp.539-549
    • /
    • 1999
  • In this paper, the bit error rare (BER) performance of DS/CDMA DQPSK communication system in the presence of multi access interference, impulsive noise and Nakagami fading is investigated. The DS/CDMA DQPSK communication system adopts Maximum Ratio Combining (MRC) diversity reception and error correcting BCH code technique to enhance system performance. Using the derived error probability equation, the error rate performance of DS/CDMA DQPSK communication system has been evaluated and shown in figures to discuss as a function of impulsive index(A), Gaussian noise to impulsive noise power ratio($\Gamma$'), multi access interference(Κ), Nakagami fading parameter(m), the number of diversity branch (L), the number of error correction symbol (t), PN code sequence length(N) and $E_b/N_0$. The error performance of DS/CDMA-MDPSK signals improve by adopting MRC diversity and BCH(15,7) coding technique in the environment of impulsive noise plus Nagakami fading. From the results, we known that proposed system is affected by multi access interference, impulsive noise and Nakagami fading in radio communication system environment. Also, BER performance of DS/CDMA DQPSK communication system cam be improved increasing either the power of desired signal or the value of Gaussian noise to impulsive noise power ratio. And BCH(15,7) code technique is more effective to restrain the affection of multi access, interference, impulsive noise and Nakagami fading in DS/CDMA DQPSK communication system than MRC diversity reception technique.

  • PDF

Robustness Examination of Tracking Performance in the Presence of Ionospheric Scintillation Using Software GPS/SBAS Receiver

  • Kondo, Shun-Ichiro;Kubo, Nobuaki;Yasuda, Akio
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.235-240
    • /
    • 2006
  • Ionospheric scintillation induces a rapid change in the amplitude and phase of radio wave signals. This is due to irregularities of electron density in the F-region of the ionosphere. It reduces the accuracy of both pseudorange and carrier phase measurements in GPS/satellite based Augmentation system (SBAS) receivers, and can cause loss of lock on the satellite signal. Scintillation is not as strong at mid-latitude regions such that positioning is not affected as much. Severe effects of scintillation occur mainly in a band approximately 20 degrees on either side of the magnetic equator and sometimes in the polar and auroral regions. Most scintillation occurs for a few hours after sunset during the peak years of the solar cycle. This paper focuses on estimation of the effects of ionospheric scintillation on GPS and SBAS signals using a software receiver. Software receivers have the advantage of flexibility over conventional receivers in examining performance. PC based receivers are especially effective in studying errors such as multipath and ionospheric scintillation. This is because it is possible to analyze IF signal data stored in host PC by the various processing algorithms. A L1 C/A software GPS receiver was developed consisting of a RF front-end module and a signal processing program on the PC. The RF front-end module consists of a down converter and a general purpose device for acquiring data. The signal processing program written in MATLAB implements signal acquisition, tracking, and pseudorange measurements. The receiver achieves standalone positioning with accuracy between 5 and 10 meters in 2drms. Typical phase locked loop (PLL) designs of GPS/SBAS receivers enable them to handle moderate amounts of scintillation. So the effects of ionospheric scintillation was estimated on the performance of GPS L1 C/A and SBAS receivers in terms of degradation of PLL accuracy considering the effect of various noise sources such as thermal noise jitter, ionospheric phase jitter and dynamic stress error.

  • PDF

Automated data interpretation for practical bridge identification

  • Zhang, J.;Moon, F.L.;Sato, T.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.433-445
    • /
    • 2013
  • Vibration-based structural identification has become an important tool for structural health monitoring and safety evaluation. However, various kinds of uncertainties (e.g., observation noise) involved in the field test data obstruct automation system identification for accurate and fast structural safety evaluation. A practical way including a data preprocessing procedure and a vector backward auto-regressive (VBAR) method has been investigated for practical bridge identification. The data preprocessing procedure serves to improve the data quality, which consists of multi-level uncertainty mitigation techniques. The VBAR method provides a determinative way to automatically distinguish structural modes from extraneous modes arising from uncertainty. Ambient test data of a cantilever beam is investigated to demonstrate how the proposed method automatically interprets vibration data for structural modal estimation. Especially, structural identification of a truss bridge using field test data is also performed to study the effectiveness of the proposed method for real bridge identification.

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

A semispherical SQUID magnetometer system using high sensitivity double relaxation oscillation SQUIDs for magnetoencephalographic measurements

  • Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kim, Kwoong;Park, Yong-Ki
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2003
  • We designed and constructed a multichannel superconducting quantum interference device (SQUID) magnetometer system to measure magnetic fields from the human brain. We used a new type of SQUID, the double relaxation oscillation SQUID (DROS). With high flux-to-voltage transfers of the DROS, about 10 times larger than the dc SQUIDs, simple flux-locked loop circuits could be used for SQUID operation. Also the large modulation voltage of the DROS, typically being 100 $mutextrm{V}$, enabled stable flux-locked loop operation against the thermal offset voltage drift of the preamplifier. The magnetometers were fabricated using the Nb/AlOx/Nb junction technology. The SQUID system consists of 37 signal magnetometers, distributed on a semispherical surface, and 11 reference channels were installed to pickup background noises. External feedback was used to eliminate the magnetic coupling with the adjacent channels. The liquid helium dewar has a capacity of 29 L and boil-off rate of about 4 L/d with the total 48 channel insert. The magnetometer system has an average noise level of 3 fT/√Hz at 100 Hz, inside a shielded loon, and was applied to measure auditory-evoked fields.