• Title/Summary/Keyword: l/3 Octave

Search Result 14, Processing Time 0.023 seconds

A Study on the Acoustic Characteristics of the American Adults Using Phonetic System for Sasang Constitution (한국성인(韓國成人)의 사상체질음성분석기(絲狀體質音聲分析機)를 이용한 체질별(體質別) 음향특성(音響特性) 연구(硏究))

  • Shin, Mi-Ran;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.75-88
    • /
    • 2007
  • 1. Objectives The purpose of this study was to objectively diagnose American male and female's production of two vowels /a, i/ by Sasang Constitution. 2. Methods It was analyzed the constitutional characteristics of the American adults voices with PSSC-2004. of 134 cases of vowels /a, i/ with a duration of $2.5{\sim}3$ seconds were inputted in PSSC-2004 and analyzed into 40 factors. 3. Results and Conclusions 1) APQ In the male group's production of vowel /a/, the Soyangin's APQ(l), APQ(3) and APQ(4) were significantly high compared with those of Taeumin and Soeumin. 2) Shimmer In the male group's production of vowel /a/, Soeumin's Octave1 Shimmer was significantly low compared with that of Taeumin and Soeumin. In the male group's production of vowel /i/, Soeumin's D-Shimmer was significantly low compared with that of Taeumin and Soeumin. In the female group's production of vowel /a/, the Soyangin's C-Shimmer was significantly high compared with that of Taeumin and Soeumin. 3) Octave In the male group's production of vowel /a/, the Soyangin's Octave3, Octave4, Octave5, Octave6 and Octave1 Ratio were significantly high compared with those of Taeumin and Soeumin. In the male group's production of vowels /a, i/, the Soyangin's Octave4 was significantly high compared with that of Taeumin and Soeumin. 4) Energy In the male group's production of vowel /a/, the Soyangin's Time Domain Total Sum /Time Domain Count, Freq Domain Total Sum /cnt(0), 0k-4k Total Sum, Dev., A(A#, C, E, D#, E, F#) tot E, and A(C,, D#, F#) Dev. were significantly high compared with those of Taeumin and Soeumin. In the male group's production of vowel /i/, the Soyangin's Time Domain Total Sum /Time Domain Count, Freq Domain Total Sum /cnt(0) and 0k-4k Total Sum, Dev. were significantly high compared with those of Taeumin and Soeumin. 5) Peak In the male group's production of vowels /a/ and /i/,, the Soyangin's Peak1 Ratio was significantly low compared with that of Taeumin and Soeumin. In the male group's production of vowels /a/ and /i/,, the Soyangin's Peak10 Ratio, Time Domain Peak Total/Total Energy Sum, Time Domain Peak Dev. and Total/Total Dev. Sum were significantly high compared with those of Taeumin and Soeumin. 6) It is necessary to expand the research of the acoustic analysis of American and Korean to other countries in the diagnosis of the Sasang Constitution by using the voice characteristics.

  • PDF

Design of a Tapered Slot Array Antenna with Uniplanar Feed (유니플래너 급전구조를 갖는 테이퍼드 슬롯 안테나의 설계)

  • Kim, Hye-Ri;Park, Noh-Joon;Kang, Young-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.386-391
    • /
    • 2006
  • In this paper, a design of V-type Linearly Tapered Slot Antenna(V-LTSA) with uniplanar microstrip-to-coplanar stripline(CPS) transitions is presented. The effect of reducing and increasing with taper width G, teper length L and opening angle are also considered at 5.8 GHz. In the result of a simulation by using CST-MWS, the return loss characteristic came very wide band about 4.3GHz, or 1.8 Octave. Proposed V-LTSA design schemes are expected to be a good antenna for microwave and millimeter-wave communcations.

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Analysis on Factors Affecting the Vibration of the Ballast Track in Kyeong-Bu High Speed Line (경부고속선 자갈궤도의 진동에 영향을 미치는 인자에 대한 분석)

  • Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.463-472
    • /
    • 2007
  • In this paper, the correlation between the vibration characteristics of the track components and the parameters affecting the vibration is analysed. To do it, the accelerations of each track component such as rails, sleepers and ballast are measured in Kyong-Bu high-speed line. The RMS values of the measured data are calculated and the pad stiffness, the longitudinal irregularity, running velocity and the corrugation, are considered as the parameters in the viewpoint of track. By using the linear regression, the correlation coefficient is calculated to analyse the relationship. Also, the 1/3 Octave analysis is calculated to analyse the dominant frequency band of tile vibrations of the track components.

Interior Noise Characteristics in Japanese, Korean and Chinese Subways

  • Soeta, Yoshiharu;Shimokura, Ryota;Jeon, Jin Yong;Lee, Pyoung Jik
    • International Journal of Railway
    • /
    • v.6 no.3
    • /
    • pp.120-124
    • /
    • 2013
  • The aim of this study was to clarify the characteristics of interior noise in Japanese, Korean, and Chinese subways. The octave-band noise levels, A-weighted equivalent continuous sound pressure level ($L_{Aeq}$) and parameters extracted from interaural cross-correlation/autocorrelation functions (ACF/IACFs) were analyzed to evaluate the noise inside running train cars quantitatively and qualitatively. The average $L_{Aeq}$ was 72-83 dBA. The IACF/ACF parameters of the noise showed variations in their values, suggesting they are affected by the characteristics of the trains running, wheel-rail interaction, and cross-section of the tunnels.

Prediction of Sound Radiation Power from Coupled Structures Uusing SEA (SEA법에 의한 결합구조물의 음향방사파워 예측)

  • 오재응;이명렬
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.20-28
    • /
    • 1989
  • SEA(Statistical Energy Analysis) method has been applied to predict the sound radiation power from vibrating machinery. In this study, sound radiation power was predicted from coupled structures by transmission of vibration, which composed of two plates welded into an L shape. The predicted sound radiation power is in agreement within 2 or 3 dB on octave band comparing with values obtained from direct measurements. Also, in order to prove the validity of this method in changes of sound radiation power associated with modifications to structures, rubber pad was stuck on a plate. The results agree approximately within 3 or 5 dB. And SEA method is valuable for the optimal design to reduce the noise. Additionally, this paper suggests that the logarithmic decrement method is valid as the one for finding the loss factor.

Clustering and classification of residential noise sources in apartment buildings based on machine learning using spectral and temporal characteristics (주파수 및 시간 특성을 활용한 머신러닝 기반 공동주택 주거소음의 군집화 및 분류)

  • Jeong-hun Kim;Song-mi Lee;Su-hong Kim;Eun-sung Song;Jong-kwan Ryu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.603-616
    • /
    • 2023
  • In this study, machine learning-based clustering and classification of residential noise in apartment buildings was conducted using frequency and temporal characteristics. First, a residential noise source dataset was constructed . The residential noise source dataset was consisted of floor impact, airborne, plumbing and equipment noise, environmental, and construction noise. The clustering of residential noise was performed by K-Means clustering method. For frequency characteristics, Leq and Lmax values were derived for 1/1 and 1/3 octave band for each sound source. For temporal characteristics, Leq values were derived at every 6 ms through sound pressure level analysis for 5 s. The number of k in K-Means clustering method was determined through the silhouette coefficient and elbow method. The clustering of residential noise source by frequency characteristic resulted in three clusters for both Leq and Lmax analysis. Temporal characteristic clustered residential noise source into 9 clusters for Leq and 11 clusters for Lmax. Clustering by frequency characteristic clustered according to the proportion of low frequency band. Then, to utilize the clustering results, the residential noise source was classified using three kinds of machine learning. The results of the residential noise classification showed the highest accuracy and f1-score for data labeled with Leq values in 1/3 octave bands, and the highest accuracy and f1-score for classifying residential noise sources with an Artificial Neural Network (ANN) model using both frequency and temporal features, with 93 % accuracy and 92 % f1-score.

Field Measurement of the Reverberation Time in Occupied and Unoccupied Apartment Houses (공동주택 입주 전.후 세대에서의 잔향시간 측정 및 비교)

  • Lee, Byoung-Ki;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.654-657
    • /
    • 2005
  • The aim of this study is to investigate and to analyze the reverberation times of apartment houses Measurements were conducted in a total of 44 rooms(36 rooms were in occupied houses and 8 rooms were in unoccupied houses) according to KS F 2864. The results showed that the averaged reverberation time of the occupied and the unoccupied houses were about 0.3$\sim$0.5sec and 1.2$\sim$l.5 sec, respectively, at 500Hz octave band frequency. And the averaged absorbtion coefficient of the occupied and the unoccupied houses were about 0.13$\sim$0.35 and 0.11$\sim$0.20, respectively. In addition, We verified that the reverberation time generally depended on the frequency; the lower the frequency, the higher the reverberation time.

  • PDF

Investigation into influence of sound absorption block on interior noise of high speed train in tunnel (터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰)

  • Lee, Sang-heon;Cheong, Cheolung;Lee, Song-June;Kim, Jae-Hwan;Son, Dong-Gi;Sim, Gyu-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.223-231
    • /
    • 2018
  • Recently, due to various environmental problems, blast tracks in tunnel are replaced with concrete tracks, but they have more adverse effects on noise than blast tracks so that additional noise measures are needed. Among these measures, sound-absorbing blocks start to be used due to its easy and quick installation. However, the performance of sound absorption blocks need to be verified under real environmental and operational conditions. In this paper, interior noise levels in KTX train cruising in Dalseong tunnel are measured before and after the installation of sound-absorbing blocks and the measured data are analyzed and compared. Additionally, noise reduction are estimated by modeling the high speed train, the tunnel and absorption blocks. Measurement devices and methods are used according to ISO 3381 and the equivalent sound pressure levels during the cruising time inside the tunnel are computed. In addition to overall SPLs(Sound Pressure Levels), 1/3-octave-band levels are also analyzed to account for the frequency characteristics of sound absorption and equipment noise in a cabin. In addition, to consider the effects of train cruising speeds and environmental conditions on the measurements, the measured data are corrected by using those measured during the train-passing through the tunnels located before and behind the Dalseong tunnel. Analysis of measured results showed that the maximum noise reduction of 6.8 dB (A) can be achieved for the local region where the sound-absorbing blocks are installed. Finally, through the comparison of predicted 1/3-octave band SPLs for the KTX interior noise with the measurements, the understanding of noise reduction mechanism due to sound-absorbing blocks is enhanced.

L-band Voltage Controlled Oscillator for Ultra-Wideband System Applications (초광대역 응용 시스템을 위한 L밴드 전압제어발진기 설계)

  • Koo Bonsan;Shin Guem-Sik;Jang Byung-Jun;Ryu Keun-Kwan;Lee Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.820-825
    • /
    • 2004
  • In this paper an octave tuning voltage controlled oscillator which is used in set-top TV tuner was designed. Oscillation frequency range is 0.9 GHz~2.2 GHz with 1.3 GHz bandwidth. By using 4 varactor diodes in base and emitter of transistor, wide-band tuning, sweep linearity and low phase noise could be achieved. Designed VCO requires a tuning voltage of 0 V ~ 20 V and DC consumption of 10 V and 15 mA. Designed VCO exhibits an output power of 5.3 dBm $\pm$1.1 dB and a phase noise below -94.8 dBc/Hz @ 10 kHz over the entire frequency range. The sweep linearity shows 65 MHz/V with a deviation of $\pm$10 MHz.