• Title/Summary/Keyword: kyphosis

Search Result 165, Processing Time 0.027 seconds

Comparison of the Effects of Magnetically Controlled Growing Rod and Tradiotinal Growing Rod Techniques on the Sagittal Plane in the Treatment of Early-Onset Scoliosis

  • Erdogan, Sinan;Polat, Baris;Atici, Yunus;Ozyalvac, Osman Nuri;Ozturk, Cagatay
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.577-585
    • /
    • 2019
  • Objective : Comparing the effects of magnetically controlled growing rod (MCGR) and traditional growing rod (TGR) techniques on the sagittal plane in the treatment of early-onset scoliosis (EOS). Methods : Twelve patients were operated using dual MCGR technique in one center, while 15 patients were operated using dual TGR technique for EOS in another center. Patients' demographic characteristics, complications and radiological measurements such as cobb angle, thoracic kyphosis, lumbar lordosis, T1-S1 range (mm), proximal junctional angle, distal junctional angle, sagittal balance, coronal balance, pelvic incidence, sacral slope and pelvic tilt were assessed and compared in preoperative, postoperative and last follow-up period. Results : Age and sex distributions were similar in both groups. The mean number of lengthening in the MCGR group was 12 (8-15) and 4.8 (3-7) in the TGR group. Two techniques were shown to be effective in controlling the curvature and in the increase of T1-S1 distance. In TGR group, four patients had rod fractures, six patients had screw pull-out and four patients had an infection, whereas three patients had screw pull-out and one patient had infection complications in the MCGR group. Conclusion : There was no significant difference between the two groups in terms of cobb angle, coronal and sagittal balance and sagittal pelvic parameters. MCGR can cause hypokyphosis and proximal junctional kyphosis in a minimum 2-year follow-up period. The implant-related complications were less in the MCGR group. However, larger case groups and longer follow-up periods are required for the better understanding of the superiority of one method on other in terms of complications.

Effect of Palm Facing Forward Posture on SpinoPelvic Parameters on the Whole Spine Lateral Radiography (척추 전장 측면 방사선검사 시 손바닥 정면 자세가 척추골반지표에 미치는 영향)

  • Joo, Young-Cheol;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.391-396
    • /
    • 2022
  • The purpose of this study was to investigate the effect of cross arms and palms facing forward on spinopelvic parameters during the whole spine lateral radiography. In addition, we would like to present the usefulness of a posture with the palm facing forward during whole spine lateral radiography of the spine using EOS. The subjects of this study were images of a total of 50 patients (18 males, 32 females) who whole spine lateral radiography using the conventional method and the EOS method from October 2020 to March 2021. The posture used in this study was set as 'CAP' for cross arms and 'PUSH' for posture with palms facing forward. In this study, among the spinal stability factors, thoracic kyphosis (thoracic vertebrae 4 to 12), lumbar lordosis (lumbar vertebrae 1 to sacrum 1), sagittal vertical axis, sacral slope, and shoulder flexion angle were compared on average. The mean thoracic kyphosis was 34.52±12.46° for CAP and 28.46±10.81° for PUSH (p<0.01). The lumbar lordosis of CAP was 42.45±17.45°and that of PUSH was 40.56±16.14°(p>0.57). The sagittal vertical axis was 26.59±34.34 mm in CAP and 21.21±35.41 mm in PUSH (p>0.44). In CAP, the sacral slope was 30.96±10.29°, and in PUSH, it was 31.01±10.19° (p>0.98). shoulder flexion angle was 38.31±8.24° for CAP and 26,08±6.71° for PUSH(p<0.01). As a result of this study, the PUSH posture is considered to be a posture that can minimize the shoulder flexion angle and can perform a stable examination while minimizing changes in spino-pelvic parameter.

Development of Textile Sensors for Prevention of Forward Head Posture (거북목 예방을 위한 텍스타일 센서 개발)

  • Minsuk kim;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.27 no.4
    • /
    • pp.125-140
    • /
    • 2023
  • This study aimed to develop a smart wearable device for assessing the risk angle associated with turtle neck syndrome in patients with Video Display Terminal (VDT) syndrome. Turtle neck syndrome, characterized by forward head posture resulting from upper cross syndrome, leads to thoracic kyphosis. In this research, a stretch sensor was used to monitor the progression of turtle neck syndrome, and the sensor data was analyzed using a Universal Testing Machine (UTM) and the Gauge Factor (GF) calculation method. The scapula and cervical spine angles were measured at five stages, with 15-degree increments from 0° to 60°. During the experimental process, the stretch sensor was attached to the thoracic spine in three different lengths: 30mm, 50mm, and 100mm. Among these, the attachment method yielding the most reliable data was determined by measuring with three techniques (General Trim Adhesive, PU film, and Heat Transfer Machine), and clothing using the heat transfer machine was selected. The experimental results confirmed that the most significant change in thoracic kyphosis occurred at approximately 30° of forward head posture. Prolonged deformity can lead to various issues, highlighting the need for textile sensor solutions. The developed wearable device aims to provide users with real-time feedback on their turtle neck posture and incorporate features that can help prevent or improve the condition.

Preliminary Result of Revision Fusion Surgery for Thoracolumbar Spine Using Revision Rod (Revision Rod를 이용한 흉요추 유합 재수술 예비 결과)

  • Youn, Yung-Hun;Cho, Kyu-Jung;Park, Ye-Su;Park, Jae-Woo;Park, Jin-Sung;Kwon, Won-Hwan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.520-526
    • /
    • 2020
  • Purpose: The need for revision fusion surgery after spinal fusion has increased. A revision rod that connects to the previous rod was newly developed for revision surgery. The purpose of this study was to analyze the clinical and radiological results after spinal fusion revision surgery using revision rods. Materials and Methods: Twenty-one patients who underwent revision fusion surgery after spinal fusion in two university hospitals with minimum 1 year follow-up were reviewed. This study assessed 16 cases of adjacent-segment disease, four cases of thoracolumbar fracture, and one case of ossification of ligament flavum. The Oswestry Disability Index (ODI) and numerical rating scale (NRS) were evaluated as clinical outcomes, and the union rate, lordosis or kyphosis of the revision level, lumbar lordosis, T5-12 kyphosis, and proximal junctional kyphosis angle were evaluated as the radiological outcomes. Results: The average ODI was 54.6±12.5 before surgery and improved to 29.8±16.5 at the final follow-up. The NRS for back pain and leg pain was 5.0±1.7 and 6.4±2.0 before surgery, which changed to 2.9±1.6 and 2.9±2.2 at the final follow-up. Lumbar lordosis was 18.1°±11.9° before surgery and 21.1°±10.3° at the final follow-up. Proximal junctional kyphosis was 10.8°±10.1° before surgery, and 9.2°±10.5° at the final follow-up. These angles were not changed significantly after surgery. Bony union was successful in all cases except for one case who underwent posterolateral fusion. Conclusion: Revision surgery using a newly developed revision rod on the thoracolumbar spine achieved good clinical outcomes with successful bony union. No problems with the newly developed revision rod were encountered.

Teratogenic and Embryotoxic Effects of Clomiphene Citrate in Developing Mice

  • Ara, Chaman;Asmatullah, Asmatullah
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.8
    • /
    • pp.1053-1059
    • /
    • 2011
  • The objective of this study was to assess the teratogenic and embryotoxic effects of clomiphene citrate in mice. The pregnant mice were administered a single dose of clomiphene citrate at different concentrations i.e 1.0, 2.0, 4.0 and 6.0 ${\mu}g/g$ BW on day 8 of gestation. Fetuses recovered on day 18 of gestation were analyzed on morphological, morphometric and histological basis. Morphological observations showed defects like open eyelids, anophthalmia, fore and hindlimb micromelia, meromelia, amelia, sacral hygroma, hydrocephaly, hemorrhagic spots, kyphosis and clubbed feet. Morphometric analysis indicated a significant (p<0.001) reduction in fetal body weight, crown rump length, head circumference, eye circumference, forelimb and hindlimb lengths and tail size against controls. The histological observations showed brain defects like hydrocephaly, enlarged ventricles and undifferentiated neuroglial cells in cerebellum. Cleft palate, underdeveloped pharynx and atrophy of jaw muscles were the common anatomical defects of pharyngeal region. It is concluded that the concentrations of clomiphene citrate used during the present study proved teratogenic in mice fetuses.

Lateral Laminectomy in Thoracolumbar Disc Herniated Dogs (흉요추 추간원반탈출증 권에서의 편측 추궁절제술)

  • 엄기동;윤정회
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.255-262
    • /
    • 1998
  • Lateral laminectomy was performed far spinal decompression in 7 thoracolumbar disc herniated dogs. These dogs showed upper motor neurologic signs including kyphosisi urinary dysfunction, and paraplegia or paralysis in hindlimbs. The lesions were evaluated with myelographic findings and predominated in $T_{12}-T_{13}, T_{13}-L_{1} and L_{1}-L_{2}$ discs. Five dogs which were operated within 48 hours after the onset of paraplegia were recovered from kyphosis and sustained the normal gait and walkings furthermore normal urination and defecation were presented within 3 days of postoperation. One dog was expired with steroid induced intestinal bleeding. The other dog operated on 96 hours after the onset of paraplegia was not recovered from neurologic deficits. Spinal decompression technique was considered to be useful method fur improving neurological problems resulted firom thoracolumbar disc herniation, if dogs are operated on early stage of the onset of paraplegia.

  • PDF

A Diagnostic Imaging Case of Cervical Spinal Subluxation for Chuna Mannual Therapy: Cervical Malposition with OPLL

  • Na, Hyun-Jong;Chang, Seok-Gon
    • The Journal of Korean Medicine
    • /
    • v.37 no.4
    • /
    • pp.45-48
    • /
    • 2016
  • Objectives: A diagnostic imaging in a fifty five year-old woman diagnosed orthopedically as ossification of posterior longitudinal ligament (OPLL) at C5 and C6 levels was reinterpreted for Chuna mannual therapy. The cervical spinal lesion in simple X-ray and CT scan images was discussed by spinal listing systems and disc block subluxation theory. The primary adjustive target was C4 disc block subluxation, which had been affected by kyphosis. Chuna manual therapy based on diagnostic images could be helpful for adjusting spinal subluxation, correcting its adaptation curvature, and preventing its latent pathology efficiently.

The Ergonomic Perspectives on Chair Design (인간공학이 의자디자인에 미치는 영향에 관한 연구)

  • 김명태;김정호
    • Journal of the Korea Furniture Society
    • /
    • v.13 no.2
    • /
    • pp.53-62
    • /
    • 2002
  • Due to the industrial development some scholars insist that homo sapiens has become a new race--homo sedens. Since this great degree of behavioral change often cause problems in the spinal column, the appropriate sitting became critical. The nineteenth-century idea of sitting upright position is not considered as a proper sitting any longer. Recent studies by such psychological scientists as A. C. Mandal, Ernest McCormick, and Karl Kroemer show that the spinal column in s-curve with forward bends should be efficiently supported in that manner. Designing a chair sometimes focuses on aesthetic points rather than true ergonomic considerations. Therefore, these result in deleterious effects on human bodies such as lordosis and kyphosis. In fact, it has been overlooked due to the lack of technical and scientific supports. Also, in a mass production, it is hard to meet everyone's need. However, the well adapted ergonomic considerations should meet the needs for wide ranges of people. Indeed, in this study we will examine designing chairs in ergonomic perspectives and suggest additional controversial points and alternatives.

  • PDF

Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation (흉요추부 골다공증성 척추 압박 골절의 수술적 치료: 골시멘트 보강술을 이용한 척추경 나사 고정)

  • Jun, Deuk Soo;Baik, Jong-Min;Park, Ji Hyeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.327-335
    • /
    • 2019
  • Purpose: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. Materials and Methods: Twenty OVCF patients, who underwent only posterior fusion using pedicle screws with PMMA augmentation, were included in the study. The mean follow-up period was 15.6 months. The demographic data, bone mineral density (BMD), fusion segments, number of pedicle screws, and amount of PMMA were reviewed as medical records. To analyze the radiological outcomes, the radiologic parameters were measured as the time serial follow-up (preoperation, immediately postoperation, postoperation 6 weeks, 3, 6 months, and 1 year follow-up). Results: A total of 20 patients were examined (16 females [80.0%]; mean age, 69.1±8.9 years). The average BMD was -2.5±0.9 g/cm2. The average cement volume per vertebral body was 6.3 ml. The mean preoperative Cobb angle of focal kyphosis was 32.7°±7.0° and was improved significantly to 8.7°±6.9° postoperatively (p<0.001), with maintenance of the correction at the serial follow-up, postoperatively. The Cobb angle of instrumented kyphosis, wedge angle, and sagittal index showed similar patterns. In addition, the anterior part of fractured vertebral body height averaged 11.0±5.0 mm and was improved to 18.5±5.7 mm postoperatively (p=0.006), with maintenance of the improvement at the 3-month, 6-month, and 1-year follow-up. Conclusion: The reinforcement of pedicle screws using PMMA augmentation may be a feasible surgical technique for OVCF. Moreover, it appears to be appropriate for improving the focal thoracolumbar/lumbar kyphosis and is maintained well after surgery.

Radiographic and Clinical Outcomes Following Pedicle Subtraction Osteotomy : Minimum 2-Year Follow-Up Data

  • Choi, Ho Yong;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.99-107
    • /
    • 2020
  • Objective : The purpose of this study was to report the results of pedicle subtraction osteotomy (PSO) for fixed sagittal imbalance with a minimum 2-year follow-up. Besides, authors evaluated the effect of adjunctive multi-level posterior column osteotomy (PCO) on achievement of additional lumbar lordosis (LL) during PSO. Methods : A total of 31 consecutive patients undergoing PSO for fixed sagittal imbalance were enrolled and analyzed. Correction angle of osteotomized vertebra (PSO angle) and other radiographic parameters including pelvic incidence (PI), thoracic kyphosis, LL, and sagittal vertical axis (SVA) were evaluated. Clinical outcomes and surgical complications were also assessed. Results : The mean age was 66.0±9.3 years with a mean follow-up period of 33.2±10.5 months. The mean number of fused segments was 9.6±3.5. The mean operative time and surgical bleeding were 475.9±160.5 minutes and 1406.1±932.1 mL, respectively. The preoperative SRS-22 score was 2.3±0.7 and improved to 3.2±0.8 at the final follow-up. The mean PI was 54.5±9.5°. LL was changed from 7.0±28.9° to -50.2±13.2°. The PSO angle was 33.7±13.5° (15.6±20.1° preoperatively, -16.1±19.4° postoperatively). The difference of correction angle of LL (57.3°) was greater about 23.6° than which of PSO angle (33.7°). SVA was improved from 189.5±93.0 mm, preoperatively to 12.4±40.8 mm, postoperatively. There occurred six, eight, and 14 cases of complications at intraoperative, early (<2 weeks) postoperative, and late (≥2 weeks) postoperative period, respectively. Additional operations were needed in nine patients due to the complications. Conclusion : PSO could provide satisfactory results for patients with fixed sagittal imbalance regarding clinical and radiographic outcomes. Additional correction of LL could be achieved with conduction of adjunctive multi-level PCOs during PSO.