• 제목/요약/키워드: knife edge test

검색결과 22건 처리시간 0.016초

V급 와동에서 심미성 수복재의 충전 방법에 따른 변연누출에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE ACCORDING TO THE FILLING METHOD OF THE ESTHETIC MATERIALS IN CLASS V CAVITIES)

  • 박진영;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.217-227
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal leakage of esthetic restorative materials according to the filling method in class V cavities. 60 cavities were prepared on buccal surface for dye penetration test and divided into 5 experimental groups according to the filling methods of esthetic materials: group 1 was filled with glass ionomer cement, group 2, 3 and 4 were filled with the chamfer, knife edge and butt joint shaped glass ionomer cement respectively and silux plus/scotchbond 2$^{(R)}$ by sandwich technique, group 5 was lined with Dycal$^{(R)}$ and filled with silux plus/scotchbond 2$^{(R)}$ by bulk filling technique. All the specimens were then thermocycled in a range of $4^{\circ}C-60^{\circ}C$ by and immersed in 2% methylene blue dye solution for 24 hours, and sectioned mesiodistally with carborundum disk into two parts under water spray. All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The obtained results were as follows : 1. At the occlusal margins, group 2, 3, 4 and 5 showed less marginal leakage than group 1 (p<0.05) and there were not significant differences among group 2, 3, 4, and 5. 2. At the gingival margins, group 5 showed the least marginal leakage and group 4 and 5 showed less marginal leakage than group 1, 2 and 3 (p<0.05). 3. In the laminated groups, group 4 showed less marginal leakage than group 2 and 3 at the gingival margins. 4. In comparison to the occlusal and gingival margins, all groups showed less marginal leakage at the occlusal margins than at the gingival margins (p<0.05).

  • PDF

적외선 광학계용 MTF 측정장치 개발 (Development of a MTF Measurement System for an Infrared Optical System)

  • 손병호;이회윤;송재봉;양호순;이윤우
    • 한국광학회지
    • /
    • 제26권3호
    • /
    • pp.162-167
    • /
    • 2015
  • 본 논문에서는 적외선 파장대에서 렌즈의 변조전달함수(MTF)를 칼날 주사방식으로 측정하는 적외선 MTF 측정장치를 구성하고 평가하였다. 측정장치는 물체부, 평행광을 만들어주는 시준부, 형성된 상을 분석하는 분석부로 나뉜다. 광원으로는 텅스텐 필라멘트 광원을 사용하였으며 중적외선 영상을 검출하기 위해 MCT를 사용하였다. 이 장치를 사용하여 ZnSe 재질의 f 수가 5인 표준렌즈의 MTF를 중적외선 파장대인 $3{\sim}5{\mu}m$에서 측정하고 Zemax 프로그램을 통해 계산한 이론값과 측정값 차이를 비교하여 차단주파수(Cut-off frequency)인 50 1/mm까지 전구간에서 ${\pm}0.035$이내임을 확인하였다. 또한 측정값의 신뢰도를 확인하기 위한 A형 측정불확도를 계산한 결과 MTF의 대표 공간 주파수인 20 1/mm에서 0.002으로 동일한 조건 하에서 측정 시 측정값의 변화가 거의 없음을 알 수 있었다.