• Title/Summary/Keyword: keeping warm

Search Result 49, Processing Time 0.027 seconds

Textural Changes of Cooked-Rice during Warm Keeping in Electrical Rice Cooker (전기밥솥에서 보온중인 밥의 조직감 변화)

  • Lee, Y.J.;Hwang, S.W.;Kim, S.K.;Park, Y.S.;Chun, J.K.
    • Applied Biological Chemistry
    • /
    • v.38 no.5
    • /
    • pp.422-424
    • /
    • 1995
  • In order to investigate the textural changes of cooked rice in a home electrical rice cooker during warm keeping period, rice was cooked and stored at $73^{\circ}C$ for 42 hours. The time course changes of hardness and adhesiveness of cooked rice were measured with the specimen prepared as a cylindrical rice block(H/D= 15 mm/20 mm). At the initial stage of warm keeping period the hardness was 1.61 kg and it was increased steadily to 1.95 kg up to 12 hours. And it was rapidly dropped to 1.57 kg within 3 hours, and thereafter gradually decreased to 1.44 kg. The adhesiveness was steadily declined with warm keeping period from 0.51 to 0.323kg set The cohesiveness and chewiness were also changed in the similar pattern to that of hardness while the springiness remained unchanged throughout the whole warm keeping period.

  • PDF

Development of Manufacturing Method of Vessel for Keeping Warm by Hydraulic Bulging (액압벌징에 의한 보온용기의 제조방법 개발)

  • Chung, Joon-Ki;Cho, Woong-Shick
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.24-31
    • /
    • 1999
  • Bulging is a forming method to shape of die cavity by using hydraulic pressure in tube or vessel. Bulging machine and die were developed in order to produce vessel for keeping warm. Bulging machine is a double type with two horizontal cylinders for bulging of two pieces at the same time. The developed die system has one bulging die and two drawing dies for necking at the both ends of tube. The diameter of tube expands by hydraulic pressure in tube. at the same time, thrust at the both ends of tube. pushes tube in the direction of expansion to obtain high expanding rate with no crack. In this study, the bulging properties were investigated to solve tube crack and necking in manufacturing vessel by the combination method of bulging and drawing. As a result, high expanding rate of tube radius without crack, precision necking and high productivity were obtained.

  • PDF

Development of Manufacturing Method of Vessel for Keeping Warm by Hydraulic Bulging

  • Chung, Joon-Ki;Cho, Woong-Shick
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.40-46
    • /
    • 2001
  • Bulging is a forming method to shape die cavity by using hydraulic pressure in tube or vessel. Bulging machine and die were developed in order to produce vessel for keeping warm. Bulging machine is a double type with two horizontal cylinders for bulging of two pieces at the same time. The developed die system has one bulging die and two drawing dies for necking at both ends of the tube. The diameter of tube expands by hydraulic pressure in tube. At the same time, thrust at both ends of the tube pushes tube in the direction of expansion to obtain high expansion rate with no crack. In this study, the bulging properties were investigated to solve tube crack and necking in manufacturing vessel by combining bulging and drawing. As a result, high expanding rate of tube radius without crack, precision necking and high productivity were obtained.

  • PDF

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Research on warmth-keeping, anti-bacteria and deodorant treatment for feet, the active organ of human body (행동기관으로서 발의 보온 및 항균방취에 대한 연구)

  • 한상덕;이상도;정중희
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.41-44
    • /
    • 1987
  • Researches were made on foot-warming, anti-bacteria and deodorant treatment. Feet, the very important organ to human body, perspire much and their temperature is lower than those of other parts. Hence, keeping feet warm, sanitary and deodorant is the area of this study. Latex sponge of activated carbon, impregnated open cell foam, treated with Vikol DZ-anti-bacteria finishing agent, was developed and tested for warmth-keeping by KSK 0560 test method and for sanitization by AATCC 90 HALO test method and for deodorization by wearing tests. The results show that the new developed latex spongee has warmth-keeping ratio of 2.5 times higher than that of the conventional spong and it has an excellent anti-bacteria effect. Actual wearing function tests also show that it improves significantly the performance of deodorization, sanitization, warmth-keeping and bulkiness.

  • PDF

The cases report of postpartum hyperhidrosis caused by keeping overwarm (산욕기 과보온으로 야기된 산욕기 발한 과다에 대한 증례 보고)

  • Cho, Hyung-Lae
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.4
    • /
    • pp.203-210
    • /
    • 2005
  • Purpose : The keeping warm and avoidance of cold are one of important Korean traditional postpartum care, but sometimes overwarm for example over-bundling, an overheated room or a steam bath cause heavy sweats. I observed and treated three patients complained of heavy sweats, chills, fatigue, malaise, cold sensation and pain caused by keeping overwarm for postpartum care. Although the symptoms have aggravated, they have maintained keeping overwarm because of a belief of Korean traditional postpartum care. The purpose of these cases studies are to report postpartum hyperhidrosis caused by keeping overwarm and to make a point of keeping the appropriate room temperature and humidity during puerperium. Methods : I observed and treated three patients complained of heavy sweats, chills, fatigue, malaise, cold sensation and pain caused by keeping overwarm for postpartum care. I found that a cause of the symptoms was hyperhidrosis by keeping overwarm, and administered herbal medicine and was to keep the appropriate room temperature. Results : After medication of Herbal medicine(補中益氣湯加味方) and keeping the appropriate room temperature, they were improved. Conclusion : Postpartum care is not to keep overwarm but to keep the appropriate room temperature and humidity.

  • PDF

The Physical Property of Nylon/PP Warm-up Knitted Fabric for High Emotional Garment (고감성 의류용 Nylon/PP 온감 니트 소재의 물성)

  • Kim, Hyun Ah;Jang, Hong Won;Heo, Kyoung;Kim, Seung Jin;Kwon, Sang Jun
    • Textile Coloration and Finishing
    • /
    • v.26 no.1
    • /
    • pp.22-31
    • /
    • 2014
  • This study investigated the physical properties of warm up yarns and their knitted fabrics including the dye affinity and color fastness to washing of these knitted fabrics according to the various dyeing times and temperatures on dyeing process. The results were summarized as follows. The tenacity of Nylon/PP warm-up yarn was 4g/d and breaking strain was 4.5%. The wet and dry thermal shrinkages were higher than those of PET warm-up yarn. The maximum heat flow rate(Qmax) of Nylon/PP warm-up knitted fabric was lower than that of PET warm-up knitted fabric and heat keeping rate(a) of Nylon/PP warm-up knitted fabric was higher as 47% than that of PET warm-up knitted fabric. It was shown that the shape retention and wearing comfort of Nylon/PP warm-up knitted fabric were better than those of PET warm-up knitted fabric. The dye-affinity(K/S) of Nylon/PP warm-up knitted fabric showed maximum value at the dyeing condition of 40minute or 50minute dyeing time with $80^{\circ}C$ dyeing temperature, but PET warm-up knitted fabric showed maximum value at the 30minute or 40minute with $110^{\circ}C$ dyeing temperature. Finally, the color fastness to washing of Nylon/PP warm-up knitted fabric showed good value as between 4 and 5 grade.

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

3D FEM Analysis of Warm Forging Process Design for Socket at Automotive Steering Unit (자동차 조향장치용 소???R의 온간단조 공정 설계를 위한 3차원 유한요소해석)

  • Lee Y. S.;Lee J. H.;Lee J. Y.;Bae M. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.186-189
    • /
    • 2001
  • In keeping with the needs of the times for energy and labor saving and simplifying production processes, interests has been growing in warm forging. Moreover, it is interested in increasing the material usage and production amounts. To improve the productivity and material usage, it is studied the process design of warm forging for socket. Until now, socket is manufactured by hot forging in hammer. The percentage of material usage is under $60\%$ in hammer forging. On the other han4 the percentage can be increased over $90\%$ in warm forging. To change the process from hot forging to warm forging, process designs must be performed. In this time, by using the FEM package, DEFORM-3D, we could get the shape of 1st process and minimum sealing pressure. They are very essential design data to decrease the trial and error. Practically, the overlap defect could be detected and eliminated with design modification of rib height and fillet radius. Moreover, forging load and minimum sealing pressure was defined by the 3D FEM analysis.

  • PDF