• Title/Summary/Keyword: kappa values

Search Result 262, Processing Time 0.025 seconds

Longshore Currents Driven by Irregular Waves (불규칙파에 의한 연안류)

  • 유동훈;김창식
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.1
    • /
    • pp.12-23
    • /
    • 1995
  • Currents driven by irregular waves are modelled using numerical model with various empirical relations improved. Kitaigorodskii's equilibrium equation is refined to account for shoaling effect and used for checking the breaking condition. In order to compute the bottom friction realistically. equivalent roughness blights are estimated considering the ripple shape and bed load transport which may be significant the surf zone. Two sets of equations are employed to evaluate the ripple shape: one is suggested by Nielsen and the other by Madsen and Rogengaus. Both equations give similar shape of ripples. but Madsen et al. give lower value of ripple factor than Swart suggesting that the equivalent roughness becomes relatively small. Optimization technique is used to determine the proper values for the empirical parameters of $\kappa$-ι equations, and the longshore current velocity is computed using the values of empirical parameters determined by the optimization technique.

  • PDF

The Use of Confidence Interval of Measures of Diagnostic Accuracy (진단검사 정확도 평가지표의 신뢰구간)

  • Oh, Tae-Ho;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.319-323
    • /
    • 2015
  • The performance of diagnostic test accuracy is usually summarized by a variety of statistics such as sensitivity, specificity, predictive value, likelihood ratio, and kappa. These indices are most commonly presented when evaluations of competing diagnostic tests are reported, and it is of utmost importance to compare the accuracies of diagnostic tests to decide on the best available test for certain medical disorder. However, it is important to emphasize that specific point values of these indices are merely estimates. If parameter estimates are reported without a measure of uncertainty (precision), knowledgeable readers cannot know the range within which the true values of the indices are likely to lie. Therefore, when evaluations of diagnostic accuracy are reported the precision of estimates should be stated in parallel. To reflect the precision of any estimate of a diagnostic performance characteristic or of the difference between performance characteristics, the computation of confidential interval (CI), an indicator of precision, is widely used in medical literatures in that CIs are more informative to interpret test results than the simple point estimates. The majority of peer-reviewed journals usually require CIs to be specified for descriptive estimates, whereas domestic veterinary journals seem less vigilant on this issues. This paper describes how to calculate the indices and associated CIs using practical examples when assessing diagnostic test performance.

Validation of the Short Form Bobath Memorial Hospital Fall Risk Assessment Scale at a Specialized Geriatric Hospital in Korea (단축형 노인 낙상위험 사정도구의 타당도)

  • Sohng, Kyeong-Yae;Park, Mi Hwa;Chaung, Seung Kyo;Park, Hye Ja
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.3
    • /
    • pp.495-508
    • /
    • 2014
  • Purpose: This study was conducted in order to evaluate the reliability, validity, sensitivity, and specificity of the Short Form of Bobath Memorial Hospital Fall Risk Assessment Scale (BMFRAS-SF). Methods: A validation study was conducted on 207 elderly patients aged over 65 who were admitted to Bobath Memorial Hospital. Fall risk scores of BMFRAS, composed of eight subscales (age, fall history, physical activity, consciousness level, communication, fall risk factors, underlying disease, and medications) were assessed from the electronic medical record. BMFRAS-SF was derived from eight subscales of the BMFRAS representing the significance between fallers and non-fallers (fall history, physical activity, fall risk factors, underlying disease, and medications). Internal consistency reliability and interrater reliability were assessed by Cronbach's alpha and kappa coefficient. Validity was assessed by Spearman correlation analysis, factor analysis. Sensitivity, specificity, positive predictive and negative predictive values, and a receiver-operating characteristic curve (ROC) were generated. Results: Fallers had significantly higher risk scores than non-fallers in fall history, physical activity, fall risk factors, underlying disease, and medication scales. The BMFRAS-SF demonstrated acceptable Cronbach's alpha (.706) and kappa coefficients of .95. The BMFRAS-SF subscales showed good convergent validity and construct validity. The BMFRAS-SF presented good sensitivity(86.7%), specificity(67.9%), positive predictive value(42.9%) and good negative predictive value(94.8%) at a cut-off score of 5. Areas under the ROC curves were .860 for the BMFRAS and .861 for the BMFRAS-SF. Conclusion: The BMFRAS-SF was proved to be reliable and valid. It could be used for time-saving assessment and evaluation of the high risks for falls in clinical practice settings.

A Validation Study of the Abbreviated Self-Rated Korean Version of MINI (MINI Patient Health Survey) (한국판 단축된 자기보고형 MINI (MINI 정신건강 평가)의 타당도 연구)

  • Lim, Se-Won;Song, Han-Soo;Oh, Yun-Hee;Shin, Ho-Chul;Cho, Kwang-Hyun;Chung, Sang-Keun;Oh, Kang-Seob
    • Anxiety and mood
    • /
    • v.3 no.1
    • /
    • pp.32-40
    • /
    • 2007
  • Objectives : To investigate the validity of an abbreviated self-rated Korean version of MINI (Mini International Neuropsychiatric Interview) patient health survey which screening social anxiety disorder, panic disorder, generalized anxiety disorder, and major depressive disorder. Methods : 115 subjects completed MINI and MINI patient health survey. The validity of MINI patient health survey was assessed by whether the results from MINI patient health survey were compatible with the results from MINI or not. The Cohen's kappa value, specificity, sensitivity, positive predictive value, and negative predictive value was calculated for this purpose. Results : The Kappa values of social anxiety disorder (0.60), panic disorder (0.49), generalized anxiety disorder (0.60) and major depressive disorder without other co-morbid disorder (0.59) were at least moderate in strength of agreement. Conclusion : The abbreviated self-rated Korean version of MINI patient health survey has the moderate to good validity in social anxiety disorder, panic disorder, generalized anxiety disorder, and major depressive disorder without other co-morbid disorders. Our result suggests that this instrument might be useful for screening above 4 disorders if it is used under careful supervision of experienced clinicians.

  • PDF

The Quality Characteristics of Grape Jelly Made with Various Gelling Agents for Consumption by Elderly Women (여성 고령자를 대상으로 한 포도젤리의 겔화제에 따른 품질 특성 연구)

  • Choi, Eun-Jung;Lee, Ji-Eun;Oh, Myung-Suk
    • Korean journal of food and cookery science
    • /
    • v.23 no.6
    • /
    • pp.891-898
    • /
    • 2007
  • This study was carried out to determine the quality characteristics of grape jellies made with various gelling agents such as agar, $\kappa$-carrageenan, and gellan gum for consumption by elderly women. The concentrations of agar were 0.25, 0.35, and 0.45%, and those of the $\kappa$-carrageenan and gellan gum were 0.15, 0.3, and 0.4%, respectively. The color values, gelling temperatures, melting temperatures, break down rates, textural properties, and consumer acceptance of the grape jellies were measured. The average age of the subjects participating in the acceptance test was 82. The lightness of the grape jelly made with agar was the highest, and its redness was the lowest among the jellies. The gelling and melting temperatures for the grape jelly made with gellan gum were higher than those of the other jellies, and the melting temperatures were 37, 43, and $47^{\circ}C$ based on 0.15, 0.3, and 0.4% gellan gum content, respectively. The break down rate of the grape jelly made with gellan gum was the lowest among the jellies. These results indicate that the stability of the grape jelly made with gellan gum was superior among the jellies. The hardness, adhesiveness, and springiness of the grape jelly made with agar were lowest among the jellies, and the grape jellies made with agar(0.25% and 0.35%) and gellan gum(0.15% and 0.3%) had the highest consumer acceptance among the jellies. However, the gellan gum was deemed an inappropriate gelling agent with regard to the acceptability due to its sour and moldy taste as perceived by the participants.

Thermal conductivity of individual single-crystalline Bi nanowires grown by stress-induced recrystallization

  • Roh, Jong-Wook;Chen, Ren-Kun;Lee, Jun-Min;Ham, Jin-Hee;Lee, Seung-Hyn;Hochbaum, Allon;Hippalgaonkar, Kedar;Yang, Pei-Dong;Majumdar, Arun;Kim, Woo-Chul;Lee, Woo-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.23-23
    • /
    • 2009
  • It has been challenging to increase the thermoelectric figure of merit ($ZT=S^2{\sigma}T/\kappa$) of materials, which determine the efficiency of thermoelectric devices, because the three parameters Seebeck coefficient (S), electrical conductivity ($\sigma$), and thermal conductivity ($\kappa$) of bulk materials are inter-dependent. With the development of nanotechnology, ZT values of nanostructured materials are predicted to be enhanced by classical size effects and quantum confinement effects. In particular, Bi nanowires were suggested as one of ideal thermoelectric materials due to the expected quantum confinement effects for the simultaneous increase in Sand. In this work, we have investigated the thermal conductivity of individual single crystalline Bi nanowires with d = 98 nm and d = 327 nm in the temperature range 40 - 300 K using MEMS devices. The for the Bi nanowire with d = 98 nm was observed to be ~ 1.6 W/m-K at 300 K, which is much lower than that of Bi bulk (8 W/m-K at 300 K). This indicates that the thermal conductivity of the Bi suppressed due to enhanced surface boundary scattering in one-dimensional structures. Our results suggest that Bi nanowires grown by stress-induced method can be used for high-efficiency thermoelectric devices.

  • PDF

Curcumin Conjugates Induce Apoptosis Via a Mitochondrion Dependent Pathway in MCF-7 and MDA-MB-231 Cell Lines

  • Singh, Durg Vijay;Agarwal, Shikha;Singh, Preeti;Godbole, Madan Madhav;Misra, Krishna
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5797-5804
    • /
    • 2013
  • In order to enhance the bioavailability of curcumin its conjugates with piperic acid and glycine were synthesized by esterifying the 4 and 4' phenolic hydroxyls, the sites of metabolic conjugation. Antiproliferative and apoptotic efficacy of synthesized conjugates was investigated in MCF-7 and MDA-MB-231 cell lines. $IC_{50}$ values of di-O-glycinoyl (CDG) and di-O-piperoyl (CDP) esters of curcumin were found to be comparable with that of curcumin. Both conjugates induced chromatin condensation fragmentation and apoptotic body formation. CDP exposure to MCF-7 cells induced apoptosis initiating loss of mitochondrial membrane potential (${\Delta}{\Psi}m$) followed by inhibition of translocation of transcription factor NF-${\kappa}B$ and release of Cytochrome-C. Reactive oxygen species (ROS) production was evaluated by fluorescent activated cell sorter. Change in ratio of Bcl2/Bclxl was observed, suggesting permeablization of mitochondrial membrane leading to the release of AIF, Smac and other apoptogenic molecules. DNA fragmentation as a hallmark for apoptosis was monitored by TUNEL as well as agrose gel electrophoresis. Thus, it was proven that conjugation does not affect the therapeutic potential of parent molecule in vitro, while these could work in vivo as prodrugs with enhanced pharmacokinetic profile. Pharmacokinetics of these molecules under in vivo conditions is a further scope of this study.

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

Sediment Discharge Based on a Time-Integrated Point Sample (연속점 채취를 이용한 유사량 계산)

  • 정관수
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.129-141
    • /
    • 1996
  • A procedure for computing total suspended sediment load is presented based on a single point-integrated sample, a power velocity distribution, and Laursen's sediment concentration distribution equation. The procedure was tested with field data from the Rio Grande River. Computed concentrations agreed well with depth-integrated measurements corrected for unmeasured load using nominal values of $\beta$, $\kappa$ and w. Even better agreement was obtained when site-specific data were used to define the x and z exponents of the velocity and concentration distributions. The difference between total suspended load computed using a single measurement and this procedure and conventional computations based on depthintegrated measurements is well within sampling error. There are major advantages in estimating total suspended load using a single time-integrated suspended-sediment point sample. Less field time is required; sampling costs are greatly reduced; and sampling can be more frequent and better timed to measure the changing sediment load. Single-point sampling makes automatic sampling procedures more feasible.

  • PDF

Change Vector Analysis : Change detection of flood area using LANDSAT TM Data (LANDSAT TM을 이용한 홍수지역의 변화탐지 : Change Vector Analysis 방법을 중심으로)

  • Yoon, Geun-Won;Yun, Young-Bo;Park, Jong-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.2 s.25
    • /
    • pp.47-52
    • /
    • 2003
  • Change detection and analysis is a powerful application of remote sensing, in that the spectral resolution of multi-band sensors can be used to advantage in monitoring both significant and subtle land cover changes over time. In this study, the LANDSAT TM data was used to detect the change areas affected by flood from a heavy rainfall. The study area is the Nakdong River located in the Korea peninsular. Among the several change detection techniques, change vector analysis(CVA), principle component analysis(PCA) and image difference approach are utilized in this paper. CVA uses any number of spectral bands from multi-date satellite data to produce change image that yield information of the magnitude and direction of differences pixel values. And accuracy assessment was carried out with a change image produced from three techniques. In result, CVA was found to be the most accurate for detecting areas affected by flood. CVA with the overall accuracy and Kappa coefficient of 97.27 percent and 94.45 percent, respectively.

  • PDF