• Title/Summary/Keyword: kVp

Search Result 849, Processing Time 0.023 seconds

Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment (이동형 치과 X선 발생장치의 공간선량 분포)

  • Han, Gyeong-Soon;Ahn, Sung-Min
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.254-258
    • /
    • 2015
  • To compare the stationary dental X-ray generator and the portable dental X-ray generator and to understand spatial radiation dose depended on locations by measuring spatial radiation dose of the portable dental X-ray generator. The researchers used an Ionization chamber to measure spatial radiation dose which was generated while applying X-ray radiation to real bone skull phantom with both portable and stationary dental X-ray generator. There were 4 measurement locations which were immediate anterior, right, left and posterior. Distance of measurement was 50 cm in every location and the recorded result is an average of two applications of X-ray radiation to the maxillary molar area under the condition of 70 kVp, 3 mA, 0.1 sec. Average spatial radiation dose of portable X-ray generator was $37.51{\mu}Sv$, much higher than that of stationary X-ray generator which was $10.77{\mu}Sv$ (p<0.001). The result of the spatial radiation dose of the portable X-ray generator showed a huge difference depending on types of units which varied from $17.77{\mu}Sv$ to $68.90{\mu}Sv$ (p<0.05), also depending on the measurement location, immediate anterior resulted in the highest radiation dose of $54.14{\mu}Sv$ and immediate right was the lowest of $13.60{\mu}Sv$. Immediate left and posterior, however, resulted in similar radiation dose which were $42.12{\mu}Sv$, $40.18{\mu}Sv$ (p<0.01). With this result, we claim that usage of portable dental X-ray generator should be restricted to patients who can't move and exposure to radiation should be minimized by wearing lead-apron.

The Effect of Total Dose of Radiation on Normal Colon of Hybrid Mice (치료방사선 조사가 잡종 백색마우스의 대장에 미치는 병리조직학적 영향)

  • Jho, Gil-Ho;Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.99-105
    • /
    • 1986
  • Optimal balance between control probability and risk of complication is emphasized even in present time, Although certain incidence of intestinal injury is accepted as an inevitable consequence after abdominopelvic irradiation, these complications still remain as problems. 60 mice were irradiated with 250 kVp orthovoltage x-ray machine and $200rad{\times}5/wk$ regimen. Histpathologic findings of colorectum and the relationship with occult blood test were analyzed and possible tolerable dose which would be safe from permanent complication was also estimated. Followings are the results: Mild mucosal and submucosal edema were observed in 1,000 rad irradiated group. Congestion of small vessels was prominent in 2,000 rad irradiated group and infiltration of inflammatory cells was observed in 3,000 rad irradiated group. Denuded mucosa was observed in 3,000 rad irradiated group. Occult blood test is not a proper indicator for rectal denuding or rectal ulcer, but our results suggest the possibility of using this as a relative scale of intestinal damage. Mitotic figures of crypt cells were observed even in 5,000 rad irradiated group, these suggest that the repair capacity of crypt cells are still functioning.

  • PDF

Discrimination of Postradiotherapy Lung Fibrosis from Recurrence by Gallium-67 Scan in Lung Cancer (갈륨 스캔을 이용한 폐암의 치료 후 섬유성 변성과 재발의 감별)

  • Ryu, Sam-Uel;Lee, Jae-Tae
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.81-85
    • /
    • 1991
  • The differentiation between post-radiotherapy lung fibrosis and tumor recurrence is often a dilemma to physicians. Twenty two patients with lung cancer who had received 45~60 Gy to the chest were chosen to study the possible role of gallium-67 scan. Seventeen squamous cell carcinomas were treated with only radiotherapy, 3 small cell carcinomas with combination chemotherapy, 2 adenocarcinomas with lobectomy. A total of 8 patients with pneumonitis with or without fibrosis and recurrence showed uptake of gallium at the site of inflammation. Of the 12 recurrences and residual diseases after radiotherapy, positive gallium uptake was present in 11 cases (92%). Of the 10 recurrence-free cases, all the 5 patients with pneumonitis revealed gallium accumulation. However, 4 of the 5 patients (80%) with recurrence-free fibrosis have not accumulated gallium in the fibrotic areas. Fibroses in S patients were developed after 8 months of completion of radiotherapy. These facts suggest that gallium-67 scan after 1 year post-treatment may aid for the discrimination of fibrosis from tumor recurrence unless pneumonitis is present.

  • PDF

Quantitative Analysis of Bone Mineral Measurements in Different Types of Dual-energy Absorptiometry Systems: Comparison of CT vs DEXA (이중 에너지 조사 방식의 장비별 골밀도 측정의 정량적 비교 분석: CT vs DEXA 비교)

  • Kim, Myeong Seong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.311-316
    • /
    • 2017
  • Generally assessing bone mineral density (BMD) were performed on dual energy X-ray absorptiometry (DEXA) the same as dual energy CT (DECT) with a rapid-kVp switching. The purpose of this study is to compare the different of BMD value between DEXA and DECT method, and evaluate usefulness of DECT method. Using scanner for BMD measurements were GE, Healthcare Discovery 750 HD for DECT and Hologic QDR 4500W for DEXA. For compare BMD value in each method, scanned lumbar spine phantom and subjects visiting Korean National Cancer Center from April 2015 to December 2015, records of 50 patients. This study was approved by the Institutional Review Board. The mean BMD value measures for spine phantom and for subjects in each scanners presented strong correlation (r=0.948 with p<0.05 for phantom; r=0.635 with p<0.05 and Kendall's tau $({\tau})=0.46$ with p<0.05 for subjects) and linear relationship between DECT and conventional DEXA. DECT technique for BMD measurement will provide a very useful methodology without additional radiation dose.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

TOPSIS-Based Multi-Objective Shape Optimization for a CRT Funnel (TOPSIS 를 적용한 CRT 후면유리의 다중목적 형상최적설계)

  • Lee, Kwang-Ki;Han, Jeong-Woo;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.729-736
    • /
    • 2011
  • The technique for order preference by similarity to ideal solution (TOPSIS) is regarded as a classical method of multiple attribute decision making (MADM), often used to solve various decision-making or selection problems. It is based on the concept that the chosen alternative should have the shortest distance from the positive ideal solution and the farthest distance from the negative ideal solution. The TOPSIS can be applied to a design process for carrying out multi-objective shape optimization wherein the best and worst alternatives are to be decided. In this paper, multi-objective shape optimization using the TOPSIS and Rational Bezier curve was applied to the funnel of a cathode-ray tube (CRT). In order to minimize the weight and first principal stress, a new multi-objective shape optimization methodology is proposed, wherein the relative-closeness coefficients of the TOPSIS are defined as the performance indices of a multi-objective function and evaluated by response surface models. This methodology enables the designer to decide on the best solution from a number of design specification groups by examining the various conflicts between the weight and the first principal stress.

Robust Optimal Design of Disc Brake Based on Response Surface Model Considering Standard Normal Distribution of Shape Tolerance (표준정규분포를 고려한 반응표면모델 기반 디스크 브레이크의 강건최적설계)

  • Lee, Kwang-Ki;Lee, Yong-Bum;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1305-1310
    • /
    • 2010
  • In a practical design process, the method of extracting the design space information of the complex system for verifying, improving, and optimizing the design process by taking into account the design variables and their shape tolerance is very important. Finite element analysis has been successfully implemented and integrated with design of experiment such as D-Optimal array; thus, a response surface model and optimization tools have been obtained, and design variables can be optimized by using the model and these tools. Then, to guarantee the robustness of the design variables, a robust design should be additionally performed by taking into account the statistical variation of the shape tolerance of the optimized design variables. In this study, a new approach based on the use of the response surface model is proposed; in this approach, the standard normal distribution of the shape tolerance is considered. By adopting this approach, it is possible to simultaneously optimize variables and perform a robust design. This approach can serve as a means of efficiently modeling the trade-off among many conflicting goals in the applications of finite element analysis. A case study on the robust optimal design of disc brakes under thermal loadings was carried out to solve multiple objective functions and determine the constraints of the design variables, such as a thermal deformation and weight.

A Study of Changes in the Primary Dose Penetrating the Protective Apron on SID in X-ray Radiography (X선촬영에서 보호앞치마를 투과한 1차 선량의 SID별 변화)

  • Choi, Seong-Kwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.501-507
    • /
    • 2016
  • This study is to figure out the amount of primary X-ray generated in SID 50cm, 1m, and 2m penetrating protective aprons in X-ray radiography for hands, skull, and lumbar spine. Results are as follows: Firstly, the exposure dose of primary X-ray which is low such as that of hand X-ray may be reduced by 270 times if protective aprons are worn, but it still slightly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Secondly, the exposure dose of primary X-ray which is moderate such as that of skull X-ray may be reduced by 22 times if protective aprons are worn, but it still fairly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Thirdly, the exposure dose of primary X-ray which is very high such as that of lumbar spine X-ray may be reduced by 13 times if protective aprons are worn, but it still penetrates a lot 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Therefore, people in X-ray room should not only wear protective aprons at any spaces that the primary X-ray can reach, but also need to stand behind the thick Pb shield to protect the body if it is inevitable to stay in the room.

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

Optimization of Wind Turbine Pitch Controller by Neural Network Model Based on Latin Hypercube (라틴 하이퍼큐브 기반 신경망모델을 적용한 풍력발전기 피치제어기 최적화)

  • Lee, Kwangk-Ki;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1065-1071
    • /
    • 2012
  • Wind energy is becoming one of the most preferable alternatives to conventional sources of electric power that rely on fossil fuels. For stable electric power generation, constant rotating speed control of a wind turbine is performed through pitch control and stall control of the turbine blades. Recently, variable pitch control has been implemented in modern wind turbines to harvest more energy at variable wind speeds that are even lower than the rated one. Although wind turbine pitch controllers are currently optimized using a step response via the Ziegler-Nichols auto-tuning process, this approach does not satisfy the requirements of variable pitch control. In this study, the variable pitch controller was optimized by a genetic algorithm using a neural network model that was constructed by the Latin Hypercube sampling method to improve the Ziegler-Nichols auto-tuning process. The optimized solution shows that the root mean square error, rise time, and settle time are respectively improved by more than 7.64%, 15.8%, and 15.3% compared with the corresponding initial solutions obtained by the Ziegler-Nichols auto-tuning process.