• Title/Summary/Keyword: kV 영상

Search Result 572, Processing Time 0.033 seconds

An Example of Internal Wave Detection in North Coastal Waters of Cheju Island Using a SAR Image (SAR를 이용한 제주도 북부해역에서의 내부파 관측예)

  • Kim, Tae-Rim;Won, Joong-Sun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.1
    • /
    • pp.18-24
    • /
    • 1999
  • The satellite image acquired by RADARSAT SAR on August 15, 1996 reveals internal waves in north coastal waters of Cheju Island. It is indicated from the image data, the tidal elevation data, and the bottom topography data, the internal waves seem to be generated by interaction between shallow bottom and tidal currents travelling in the stratified water in the summer time during the tidal changeovers from ebb to flood. The internal waves generated in such condition show patterns of trains of solitons. Probable amplitude of observed solitons is calculated using estimation of the soliton wave length from SAR image data and K-dV equation. Detection of the internal waves is very significant not only to military strategist for underwater maneuvers such as operation of submarines, but also to physical and biological oceanographers. Temporal and spatial variation of the internal waves are needed to be measured by simultaneous in-situ field study together with SAR to examine the nature of these internal waves.

  • PDF

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Small animal brain functional MRI study using light stimulation (광자극을 이용한 소동물 뇌 fMRI 연구)

  • Kim, Wook;Park, Yong Sung;Ko, In Ok;Kang, Kyung Joon;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.295-296
    • /
    • 2016
  • 본 연구에서는 LED 광 자극이 뇌의 어느 영역을 자극하여 신경신호를 전달하는지에 관해서 관찰하고자 연구를 진행하였다. 광 자극에 의한 뇌 영역의 활성변화를 관찰하기 위하여 실험용 소동물과 영상장비인 9.4T MRI를 이용하여 연구를 수행 하였다. 실험용 소동물은 Balb/c 마우스를 이용하였으며 기능적 자기공명영상 획득 방법 중 하나인 에코평면영상 기법을 이용하여 뇌 영상을 획득 하였다. 획득한 영상을 바탕으로 뇌 영역의 자극 정도를 확인해보기 위해 영상처리기법인 재편성(realignment), 일치(co-registration), 표준화(normalization), 평활화(smoothing) 방법으로 영상을 전처리 하고, statistical parametric map (SPM12)을 사용하여 분석하였다. 본 연구에서는 광자극이 소동물 뇌 영역 중 하나인 상구(Superior colliculus)영역과 대뇌의 시각피질 (visual cortex, V1) 영역에서 자극을 일으키는 것을 확인할 수 있었다.

  • PDF

Fabrication and Characteristics of a-Si : H TFT for Image Sensor (영상센서를 위한 비정질 실리콘 박막트랜지스터의 제작 및 특성)

  • Kim, Young-Jin;Park, Wug-Dong;Kim, Ki-Wan;Choi, Kyu-Man
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.95-99
    • /
    • 1993
  • a-Si : H TFTs for image sensor have been fabricated and their operational characteristics have been investigated. Hydrogenated amorphous silicon nitride(a-SiN : H) films were used for the gate insulator and $n^{+}$-a-Si : H films were depostied for the source and drain contact. The thicknesses of a-SiN : H and a-Si : H films were $2000{\AA}$, respectively and the thickness of $n^{+}$-a-Si : H film was $500{\AA}$. Also the channel length and channel width of a-Si : H TFTs were $50{\mu}m$ and $1000{\mu}m$, respectively. The ON/OFF current ratio, threshold voltage, and field effect mobility of fabricated a-Si : H TFTs were $10^{5}$, 6.3 V, and $0.15cm^{2}/V{\cdot}s$, respectively.

  • PDF

Performance Analysis of 3D-HEVC Video Coding (3D-HEVC 비디오 부호화 성능 분석)

  • Park, Daemin;Choi, Haechul
    • Journal of Broadcast Engineering
    • /
    • v.19 no.5
    • /
    • pp.713-725
    • /
    • 2014
  • Multi-view and 3D video technologies for a next generation video service are widely studied. These technologies can make users feel realistic experience as supporting various views. Because acquisition and transmission of a large number of views require a high cost, main challenges for multi-view and 3D video include view synthesis, video coding, and depth coding. Recently, JCT-3V (joint collaborative team on 3D video coding extension development) has being developed a new standard for multi-view and 3D video. In this paper, major tools adopted in this standard are introduced and evaluated in terms of coding efficiency and complexity. This performance analysis would be helpful for the development of a fast 3D video encoder as well as a new 3D video coding algorithm.

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection (홍삼 내공검출을 위한 X-선 영상처리기술)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.457-463
    • /
    • 2002
  • 이 연구는 x-선 투과영상을 이용하여 홍삼의 내공을 검출하기 위하여 수행되었다. 이를 위하여 x-선관에 조사되는 x-ray 양의 차이에 따른 위치별 밝기 값 차이를 보정하고 내공 검출에 적합한 영상처리 알고리즘을 개발하였다. 주요연구 결과를 요약하면 다음과 같다. 1) x-선관에 조사되는 x-ray양은 중심에서 가장자리로 갈수록 감소하며, 이것은 위치에 따른 gray 값의 분포가 달라지게 되는 원인이 되었다. 2) 홍삼을 2치화 하기 위해서는 동일한 x-선 조사강도에서 입력된 원 영상에서 빈 영상을 뺀 감산 영상을 만들어 줌으로써 가능하였다. 3) 조사강도 별 감산영상처리 결과 36kV/4.15mA와 39kV/4.15mA에서는 조사량이 많아서 홈삼 지근 부분의 영상이 손실되는 경우가 발생하였다. 4) 내공 검출을 위해서는 정상부분과 내공부분의 자기 값 차이를 크게 하는 전처리 영상을 만들 필요가 있었고, multiple 감산영상에서 뚜렷한 골짜기가 나타났으나 주근의 내공부분의 밝기값 보다 지근의 정상부분의 자기 값이 더 낮게 나타나 이를 보정하기 위하여 홍삼 위치에 따라 부분 보정된 알고리즘을 개발하였다. 5) x-선관의 놓인 위치에 따라서 내공판정시험 결과 중심에 있을 때에 비해 가장자리에 있을 때는 영상이 일부 손실되었으며, 중심 위치에서 서로 다른 굵기의 홍삼에 대해서는 모두 양호한 결과가 나타났다. 6) 완전한 홈삼으로 내공판정시험 결과 내공주위의 정상부분가지도 일부 내공으로 잘못 검출되었으나 이것을 재차 line profile에 의해 한 라인씩 문턱 값을 설정하여 내공만을 정확하게 판정하는 알고리즘을 개발하였다.양체의 접종작업은 모든 배양실이 인력에 의존하였으며, 배양체를 배지와 분리하여 불필요한 부분을 제거하고 배양작물에 따라 생육정도를 2~3등급으로 구분하여 배양용기의 배지 위에 치상하는 과정으로 수행되었으며, 작업능률은 호접란의 경우 배양병에 25본을 접종하는데 시간당 6병, 심비디움은 원형 플라스크에 25본을 접종하는데 시간당 10병 정도였다. 바. 식물체의 대량증식에 사용되는 플라스크, 배양병, PE용기 등 배양용기의 세척작업은 농원의 1개배양실에서 간이식 세척기, 이 외의 9개배양실은 모두 물에 담겨 두었다가 세제와 브러쉬 등을 사용하여 인력으로 세척하고 있어 생력화 기술개발이 요구되었다.도가 빠를수록 건조속도가 빨라졌으며, 건조에너지도 1,334kcal/kg.water로 비슷하게 소요되었다. 마. 시험구와 대비구의 건감률은 시험구에서 1.08~1.36w.b./h로 나타나 대비구보다 약 9.9~18.3%가 높게 나타났고, 건조에너지는 10.2~14.6%가 절감되었다. 발아율은 열풍온도가 낮을수록 높게 나타났고 시험구가 대비구보다 발아율이 낮게 나타났으며, 동할률 증가량도 원적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성

  • PDF

Image Evaluation according to Tube Current of X-ray Device for Intraoral Imaging (구내 촬영용 엑스선 장치의 관전류에 따른 영상 평가)

  • A Yeon Kim;Byungdu Jo;Seung-Jae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.515-521
    • /
    • 2023
  • The radiation dose received by the patient varies according to the tube current and time used during dental intraoral imaging. A large amount of tube current is required for image quality, but the radiation dose to the patient increases accordingly. Therefore, in this study, the optimal amount of tube current that can reduce the radiation dose received by the patient while securing the image quality was calculated through the evaluation of the image quality according to the tube current used during intraoral imaging through simulation. The average tube current, time, and tube voltage presented in the Guidelines for Diagnostic Reference Level for intraoral radiography were used as basic imaging conditions, and images were obtained when only the tube current was changed, and then the optimal tube current was compared and analyzed with the basic image quantity was calculated. Images were obtained by changing the tube current to 0.1, 0.5, 1, 2, 3, 4 and 5 mA under the basic conditions of 63 kV, 6 mA, and 0.29 s. The obtained image was evaluated for structural similarity index with the image taken under the condition of 6 mA using the ICY program. As a result, even under the condition of 0.5 mA tube current, the index of structural similarity with the image of 6 mA was evaluated to be high. Based on these results, it is considered that the radiation dose given to the patient can be greatly reduced if imaging is performed at 0.5 mA instead of 6 mA during dental intraoral imaging.

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF