• Title/Summary/Keyword: k-out of-n systems

Search Result 346, Processing Time 0.024 seconds

Characteristics of the Angular-dependent Exchange Coupling Bias in Multilayer [Pt/Co]N-IrMn with Toward-in Plane Applied Fields (박막수직방향에서 면방향으로 회전하는 인가자기장에 대한 다층박막 [Pt/Co]N-IrMn의 교환바이어스의 각도의존특성)

  • Kim, S.S.;Yim, H.I.;Rhee, J.R.;Lee, S.S.;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.4
    • /
    • pp.142-146
    • /
    • 2008
  • The angular dependence of the exchange bias($H_{ex}$) and coercivity($H_c$) in multilayer $[Pt/Co]_N-IrMn$ with applied measuring field rotated toward in-plane at angle $\theta$ from perpendicular-to-plane, has been measured. Multilayer films consisting of $Si/SiO_2/Ta(50)/Pt(4)/[Pt(15)/Co(t_{Co})]_N/IrMn(50)/Ta(50)(in\;{\AA})$ were prepared by magnetron sputtering under typical base pressure below $2{\times}10^{-8}$ Torr at room temperature. Magnetization measurements were performed on a vibrating sample magnetometer and extraordinary Hall voltage measurement systems after cooling from 550 K under a field of 2 kOe applied along the perpendicular to film direction. The hysteresis loop shifts from the origin not only along the field axis but also along the magnetization axis. $H_{ex}$ and $H_c$ show a $1/cos{\theta}$ and $1/|cos{\theta}|$ dependence on the angle($\theta$) between the applied measuring field and the perpendicular-film direction, respectively. This $1/cos{\theta}$ dependence can be accounted for by considering the angular dependence of strong out-of-plane magnetic anisotropy introduced during the field cooling.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

Pyroelectric and pyromagnetic effects on behavior of magneto-electro-elastic plate

  • Kondaiah, P.;Shankar, K.;Ganesan, N.
    • Coupled systems mechanics
    • /
    • v.2 no.1
    • /
    • pp.1-22
    • /
    • 2013
  • Under thermal environment, Magneto-Electro-Elastic (MEE) material exhibits pyroelectric and pyromagnetic effects which can be used for enhancing the performance of MEE sensors. Recently studies have been published on material constants such as pyroelectric constant and pyromagnetic constant for magneto-electro-thermo-elastic smart composite. Hence, the main aim of this paper is to study the pyroelectric and pyromagnetic effects on behavior of MEE plate under different boundary conditions subjected to uniform temperature. A numerical study is carried out using eight noded brick finite element under uniform temperature rise of 100 K. The study focused on the pyroelectric and pyromagnetic effects on system parameters like displacements, thermal stresses, electric potential, magnetic potential, electric displacements and magnetic flux densities. It is found that, there is a significant increase in electric potential due to the pyroelectric and pyromagnetic effects. These effects are visible on electric and magnetic potentials when CFFC and FCFC boundary conditions are applied. Additionally, the pyroelectric and pyromagnetic effects at free edge is dominant (nearly thrice the value in CFFC in comparison with FCFC) than at middle of the plate. This study is a significant contribution to sensor applications.

The effect of flavonoids on the TREK-1 channel (TREK-1 채널에 대한 플라보노이드의 효과)

  • Kim, Yang-Mi;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2660-2667
    • /
    • 2011
  • TREK-1 channel is a member of the two-pore domain potassium (K2P) channel family that is regulated by intracellular pH, membrane stretch, polyunsaturated fatty acids, temperature, and some neuroprotectant agents. TREK-1 channel can influence neuronal excitability by regulating leakage of potassium ions and resting membrane potential. TREK-1 channel has been shown to be overexpressed in prostate cancer cells. Although the importance of these properties, relatively little is known about flavonoid effects in the regulations of TREK-1 channel. The purpose of the study was to screening of flavonoids as the TREK-1 channel modulator using one of electrophysiological techniques such as excised inside-out patch configuration. We demonstrated blocking effect on TREK-1 channel by flavonoids such as epigallocatechin-3-gallate (EGCG), curcumin and quercetin in CHO cells transiently expressing TREK-1 channel. The inhibition of TREK-1 channel by quercetin and curcumin was reversible, whereas EGCG was little reversible. Quercetin, EGCG and curcumin decreased the relative channel activity to 73%, 91% and 94%, respectively. The half-inhibitory concentration (IC50) of curcumin, quercetin and EGCG was $1.04{\pm}0.19\;{\mu}M$, $1.13{\pm}0.26\;{\mu}M$ and $13.5{\pm}2.20\;{\mu}M$ in CHO cells expressing TREK-1 channel, respectively. These results indicate that flavonoids might regulate TREK-1 and this regulation might be one of the pharmacological actions of flavonoid in nervous systems and cancer cells.

Modified Particle Swarm Optimization with Time Varying Acceleration Coefficients for Economic Load Dispatch with Generator Constraints

  • Abdullah, M.N.;Bakar, A.H.A;Rahim, N.A.;Mokhlis, H.;Illias, H.A.;Jamian, J.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.15-26
    • /
    • 2014
  • This paper proposes a Modified Particle Swarm Optimization with Time Varying Acceleration Coefficients (MPSO-TVAC) for solving economic load dispatch (ELD) problem. Due to prohibited operating zones (POZ) and ramp rate limits of the practical generators, the ELD problems become nonlinear and nonconvex optimization problem. Furthermore, the ELD problem may be more complicated if transmission losses are considered. Particle swarm optimization (PSO) is one of the famous heuristic methods for solving nonconvex problems. However, this method may suffer to trap at local minima especially for multimodal problem. To improve the solution quality and robustness of PSO algorithm, a new best neighbour particle called 'rbest' is proposed. The rbest provides extra information for each particle that is randomly selected from other best particles in order to diversify the movement of particle and avoid premature convergence. The effectiveness of MPSO-TVAC algorithm is tested on different power systems with POZ, ramp-rate limits and transmission loss constraints. To validate the performances of the proposed algorithm, comparative studies have been carried out in terms of convergence characteristic, solution quality, computation time and robustness. Simulation results found that the proposed MPSO-TVAC algorithm has good solution quality and more robust than other methods reported in previous work.

Estimation of Kinetic Parameters of Nonenzymatic Browning Reaction Using Equivalent Time at Reference Temperarture with Linearly Increasing Temperature Profile (정속가열(定速加熱)조건에서 표준온도상당시간(相當時間)을 이용한 비효소적 갈색화 반응의 동력학 파라미터 추정(推定))

  • Cho, Hyung-Yong;Kwon, Yun-Joong;Kim, In-Kyu;Pyun, Yu-Ruamg
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.178-184
    • /
    • 1993
  • The procedure using equivalent time at reference temperature has been assessed for the estimation of kinetic parameters with experimental data. Kinetic studies of nonenzymatic browning reaction in model and food system were carried out with linearly increasing temperature method. These kinetic parameters, n, $k_{ref}$ and $E_a$ of the systems were evaluated from original data in one step by nonlinear least square regression. The one step procedure yielded efficiently accurate parameter estimation. Computer simulated data with the kinetic models were well consistent with experimental data (average correlation coefficient=0.96).

  • PDF

A Study on Frequency Sharing of Fixed Satellite Service with Microwave Landing System (고정위성업무와 마이크로파착륙장치 간의 주파수 공유 연구)

  • Jun, Byung-Kyu;Kang, Ji-Han;Lim, Sang-Seok;Lee, Jae-Wook;Oh, Dae-Sub;Gam, Hye-Mi
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.1
    • /
    • pp.11-17
    • /
    • 2011
  • In this paper, we consider the frequency sharing feasibility of Fixed Satellite Service (FSS) with Microwave Landing System (MLS) allocated in the C-band. On the basis of characteristics of MLS and FSS suggested by ITU and safety standards of MLS by ICAO, three interference scenarios are built and numerical simulations are carried out for investigating the frequency sharing between the two systems. From the simulation results, we calculate the separation distance between MLS and FSS ground antennas, required for frequency sharing by employing standard protection limits regulating the interference to noise ratio (I/N) of the receiver.

Review of Failure Mechanisms on the Semiconductor Devices under Electromagnetic Pulses (고출력전자기파에 의한 반도체부품의 고장메커니즘 고찰)

  • Kim, Dongshin;Koo, Yong-Sung;Kim, Ju-Hee;Kang, Soyeon;Oh, Wonwook;Chan, Sung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.37-43
    • /
    • 2017
  • This review investigates the basic principle of physical interactions and failure mechanisms introduced in the materials and inner parts of semiconducting components under electromagnetic pulses (EMPs). The transfer process of EMPs at the semiconducting component level can be explained based on three layer structures (air, dielectric, and conductor layers). The theoretically absorbed energy can be predicted by the complex reflection coefficient. The main failure mechanisms of semiconductor components are also described based on the Joule heating energy generated by the coupling between materials and the applied EMPs. Breakdown of the P-N junction, burnout of the circuit pattern in the semiconductor chip, and damage to connecting wires between the lead frame and semiconducting chips can result from dielectric heating and eddy current loss due to electric and magnetic fields. To summarize, the EMPs transferred to the semiconductor components interact with the chip material in a semiconductor, and dipolar polarization and ionic conduction happen at the same time. Destruction of the P-N junction can result from excessive reverse voltage. Further EMP research at the semiconducting component level is needed to improve the reliability and susceptibility of electric and electronic systems.

Sporicidal Efficacy of a Fumigation Disinfectant Composited to Ortho-phenylphenol Against Spores of Clostridium Perfringens (Ortho-phenylphenol을 주성분을 하는 훈증소독제의 Clostridium perfringens 아포에 대한 살아포 효과)

  • Cha, Chun-Nam;Cho, Youyoung;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.217-222
    • /
    • 2014
  • This study was performed to evaluate the sporicidal efficacy of a fumigation disinfectant containing 20% ortho-phenylphenol against Clostridium perfringens (C. perfringens) spores. In this research, efficacy test of fumigant against C. perfringens spores was carried out according to French standard NF T 72-281. C. perfringens spores working culture suspension number (N value), all the spore numbers on the carriers exposed with the fumigant (n1, n2, and n3), the number of bacterial spore suspensions by pour plate method (N1), the number of bacterial spore suspensions by filter membrane method (N2) and the mean number of bacterial spore recovered on the control-carriers (T value) were obtained from the preliminary test. In addition, the reduction number of C. perfringens spores exposed with the fumigant (d value) was calculated using T value, the mean number of bacterial spore in recovery solution (n'1) and the mean number of bacterial spore on carriers plated in agar (n'2). N value was $4.3{\times}10^7spores/mL$, and n1, n2, and n3 were higher than 0.5N1, 0.5N2 and 0.5N1, respectively. Additionally, T value was $4.9{\times}10^5spores/carrier$. In the sporicidal effect of the fumigant, the d value was 4.52log reduction. According to the French standard for the fumigant, the d value for the effective sporicidal fumigant should be over than 3log reduction. The results indicated that Fumagari $OPP^{(R)}$ had an efficient sporicidal activity against spores of C. perfringens, then the fumigant can be applied to disinfect food materials and kitchen appliances contaminated with bacterial spores.

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.