• 제목/요약/키워드: k-$\omega$

검색결과 3,472건 처리시간 0.034초

코헤시브 실리콘 젤 보형물을 이용한 유방확대술시 보형물 크기에 따른 유방 크기 변화 예측 (Predicting the Degree of Breast Size in Augmentation with Cohesive Gel Implant)

  • 이중호;서제원;이백권;오득영;이종원;안상태
    • Archives of Plastic Surgery
    • /
    • 제37권3호
    • /
    • pp.256-258
    • /
    • 2010
  • Purpose: Predicting the change in breast size for a specific patient's need is a challenging problem in breast augmentation. We intended to investigate the postaugmentation degree of breast size according to the size of cohesive silicone gel implant. Methods: To predict post-augmentation breast size, we measured 100 patients' pre-and postoperative 3 month's bust circumference. All patients were performed by total subfascial breast augmentation with moderate profile cohesive silicone gel implant through areolar omega (transareolar-perinipple) incision. Results: According to this study, each additional one pair of 100 mL in implant size yielded an approximate 1.5 cm increase in bust circumference (p=0.006). Conclusion: From this result, we conclude that each additional one pair of 100 mL in implant volume yielded about 1.5 cm increase in bust circumference. Although this result may not be applied to every patient, we believe that it yields a practical chart that can help to predict the amount of increase in breast size with the use of cohesive silicone gel implant of a specific size preoperatively.

평판 유도 결합형 $CH_4/H_2/Ar$ 플라즈마를 이용한 GaN 건식 식각에서 공정변수가 저항성 접촉 형성에 미치는 영향 (The Effects of Etch Process Parameters on the Ohmic Contact Formation in the Plasma Etching of GaN using Planar Inductively Coupled $CH_4/H_2/Ar$ Plasma)

  • 김문영;태흥식;이호준;이용현;이정희;백영식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.438-444
    • /
    • 2000
  • We report the effects of etch process parameters on the ohmic contact formation in the plasma etching of GaN. Planar inductively coupled plasma system with $CH_4/H_2/Ar$gas chemistry has been used as etch reactor. The contact resistance and the specific contact resistance have been investigated using transfer length method as a function of RF bias power and %Ar gas concentration in total flow rate. AES(Auger electron spectroscopy) analysis revealed that the etched GaN has nonstoichiometric Ga rich surface and was contaminated by carbon and oxygen. Especially large amount of carbon was detected at the sample etched for high bias power (or voltage) condition, where severe degradation of contact resistance was occurred. We achieved the low ohmic contact of $2.4{\times}10^{-3} {\Omega}cm^2$ specific contact resistance at the input power 400 W, RF bias power 150 W, and working pressure 10mTorr with 10 sccm $CH_4$, 15 sccm H2, 5 sccm Ar gas composition.

  • PDF

탄소블록과 동봉의 접지임피던스 비교 분석 (Comparative Analysis on Ground Impedance for a Carbon Block and a Copper Rod)

  • 서재석;박희철;길경석;오재근
    • 한국전기전자재료학회논문지
    • /
    • 제26권6호
    • /
    • pp.472-477
    • /
    • 2013
  • This paper carried out the comparative analysis on ground impedance of a carbon block and a copper rod. Two types of grounding electrode were compared ; a carbon block (L : 1 m, ${\Phi}$ : 245 mm) buried at a depth of 0.8 m and a three-linked copper rod (L : 1 m, ${\Phi}$ : 10 mm) of equilateral triangles with 1 m spacing. Ground impedance depending on applied current source was evaluated by the application of a sine wave current with 60 Hz ~ 3.5 MHz, a fast-rise pulse with rising time of 200 ns, a standard lightning impulse of $8/20{\mu}s$ and a 600 Hz square wave. Ground impedance for both electrodes were almost the same value below 100 kHz, and increased rapidly afterwards. The maximum ground impedance appeared $400{\Omega}$ at around 1.5 MHz. Ground impedance of the carbon block was lower at the square wave and was higher at fast-rise pulse than that of the copper rod. Also, ground impedance as ages showed no difference for the last 8 months. From the results, it is likely that ground performance for both electrodes shows no difference against commercial frequency and lightning impulse current, while the copper rod shows better performance against a fast-rise pulse with rise-time of a few hundred ns.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

Elimination of Saturated Fatty Acids, Toxic Cyclic nonapeptide and Cyanogen Glycoside Components from Flax Seed Oil

  • Choi, Eun-Mi;Kim, Jeung-Won;Pyo, Mi-Kyung;Jo, Sung-Jun;Han, Byung-Hoon
    • Biomolecules & Therapeutics
    • /
    • 제15권1호
    • /
    • pp.65-72
    • /
    • 2007
  • Flax seed(Linseed, Linum usitatissimum L.) and its oil, a richest source of alpha-linolenic acid(ALA)(${\omega}-3$), contain saturated fatty acids, neurotoxic cyanogen glycosides and immuno-suppressive cyclic-nonapeptides. Present paper describes the development of two chemical processes, Process-A and -B, to remove saturated fatty acids and to destroy cyclic nonapeptides and cyanogen glycosides from flax seed oil. Process-A consists of three major steps, i.e., extraction of fatty acid mixture by alkaline saponification, removal of saturated fatty acid by urea-complexation, and triglyceride reconstruction of unsaturated fatty acid via fatty acyl-chloride activation using oxalyl chloride. Process-B consists of preparation of fatty acid ethyl ester by transesterification, elimination of saturated fatty acid ester by urea-complexation, and reconstruction of triglyceride by interesterification with glycerol-triacetate (triacetin). The destruction of lipophilic cyclic nonapeptide during saponification or transesterification processes could be demonstrated indirectly by the disappearance of antibacterial activity of bacitracin, an analogous cyclic-decapeptide. The cyanogen glycosides were found only in the dregs after hexane extraction, but not in the flax seed oil. The reconstructed triglyceride of flax seed oil, obtained by these two different pathways after elimination of saturated fatty acid and toxic components, showed agreeable properties as edible oil in terms of taste, acid value, iodine and peroxide value, glycerine content, and antioxidant activity.

온도변화에 따른 주석 도금한 전기 커넥터의 미동마멸 부식 거동 (Fretting Corrosion Behavior of Tin-plated Electric Connectors with Variation in Temperature)

  • 오만진;강세형;이만석;김호경
    • Tribology and Lubricants
    • /
    • 제30권3호
    • /
    • pp.146-155
    • /
    • 2014
  • In this study, we conduct fretting corrosion tests on tin-plated brass coupons to investigate the effect of temperature on fretting corrosion for various span amplitudes. We prepare a coupled fretting corrosion specimens using a tin-plated brass coupon with a thickness of $10{\mu}m$. One specimen is a flat coupon and the other specimen is a coupon with a protuberance in 1 mm radius, which is produced using 2 mm diameter steel ball. We conduct fretting corrosion tests at $25^{\circ}C$, $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$ by rubbing the coupled coupons together at the contact between the flat and protuberance coupons. We measure electric resistance of the contact during the fretting corrosion test period. There is increase in resistance with fretting cycles. It is found that rate of increase in electric resistance becomes faster with increase in testing temperature. Magnitude of friction coefficient increases with fretting span amplitudes. And, change in friction coefficient becomes desensitized to the increment in span amplitude. Assuming that failure cycle is the cycle with an electric resistance of $0.01{\Omega}$, we find that failure lifetime ($N_f$) decreases with increase in testing temperature. Furthermore, based on the assumption that the damage rate of the connector is inversely related to the failure cycle, we calculate the activation energy for fretting damage to be 13.6 kJ/mole by using the Arrhenius equation. We propose a method to predict failure cycle at different temperatures for span amplitudes below $30{\mu}m$. Friction coefficients generally increase with increase in span amplitude and decrease in testing temperature.

천이효과를 고려한 BWB UCAV 형상의 공력 특성 전산해석 (CFD Analysis of Aerodynamic Characteristics of a BWB UCAV configuration with Transition effect)

  • 조영희;장경식;신동진;박수형
    • 한국항공우주학회지
    • /
    • 제42권7호
    • /
    • pp.535-543
    • /
    • 2014
  • 비세장형, 둥근 앞전을 가지고 스팬이 1.0m로 축소된 BWB형 UCAV에 대해 완전난류, 천이 모델을 사용하여 전산해석을 수행하였다. 자유류는 받음각 -4도부터 26도까지 50m/s이며, 평균 시위 기준 레이놀즈수는 $1.25{\times}10^6$이다. 멀티블록 6면체 격자와 함께 완전난류 모델과 천이 모델의 결과를 비교하여 천이효과가 공력 특성에 미치는 영향을 살펴보았다. 풍동 실험과 비교한 결과 양/항력 계수는 해석범위 내에서 잘 일치하였으며, 피칭 모멘트는 높은 받음각에서 작게 예측됨과 동시에 난류모델에 따라 결과가 크게 달라졌다. 압력분포와 skin friction line, 축 방향 속도장을 이용하여 와류구조의 거동과 천이현상이 미치는 영향을 살펴본 결과, 천이효과를 고려하는 것이 UCAV의 정확한 와류 구조와 공력특성 예측에 필요한 것으로 확인하였다.

Metal Grids Embedded Transparent Conductive Electrode with Flexibility and Its Applications

  • Jung, Sunghoon;Lee, Seunghun;Kim, Jong-Kuk;Kang, Jae-Wook;Kim, Do-Geun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.314-314
    • /
    • 2013
  • Recently, flexibility is one of the hottest issues in the field of electronic devices. For flexible displays or solar cells, a development of transparent conductive electrodes (TCEs) with flexibility, bendability and foldability is an essential element. Hundreds of nanometers indium-tin-oxide (ITO) films have been widely used and commercialized as a transparent electrode, but their brittleness make them difficulty to apply flexible electronics. Many researchers have been studying for flexible TCEs such as a few layers of graphene sheets, carbon nanotube networks, conductive polymer films and combinations among them. Although gained flexibility, their transmittance and resistivity have not reached those of commercialized ITO films. Metal grids electrode cannot act as TCEs only, but they can be used to lower the resistance of TCEs with few losses of transmittance. However, the possibility of device shortage will be rise at the devices with metal grids because a surface flatness of TCEs may be deteriorated when metal grids are introduced using conventional methods. In our research, we have developed hybrid TCEs, which combined tens of nanometers ITO film and metal grids which are embedded in flexible substrate. They show $13{\Omega}$/${\Box}f$ sheet resistance with 94% of transmittance. Moreover, the sheet resistance was maintained up to 1 mm of bending radius. Also, we have verified that flexible organic light emitting diodes and organic solar cells with the TCEs showed similar performances compared to commercial ITO (on glass substrate) devices.

  • PDF

그라비어 인쇄용 Ag Paste의 레오로지 특성에 따른 전도성 패턴의 물성 연구 (A Study on Properties of Conductive Pattern by the Rheology Characteristics of Ag Pastes for Gravure Printing)

  • 이동욱;조미정;이미영;남수용;이택민
    • 한국인쇄학회지
    • /
    • 제26권1호
    • /
    • pp.39-50
    • /
    • 2008
  • We have manufactured Ag pastes for gravure printing by adding different solvent contents. Then the gravure printability and properties of conductive patterns gravure-printed by the different rheology characteristics of pastes were investigated. The dispersity of pastes was increased and the viscosity and shear rate dependence of viscosity for pastes were decreased by increasing the solvent content. Also storage modulus G', loss modulus G" and angular frequency value when G" starts to be bigger than G' of pastes were increased by decreasing the solvent content. These mean a flow drop of paste. As a result of gravure printing using two plates which have different line counts(175line and 350line), conductive patterns printed using 175line were spreaded more but Ag packing, thickness and conductivity of the conductive patterns were better than those printed using 350line. And the spread values of conductive patterns were increased with solvent contents but the best properties for Ag packing, surface roughness and conductivity of the conductive pattern were obtained by paste (3) which has 550cps of viscosity at $100s^{-1}$ and tan ${\delta}$ > 1 at 10rad/s. As a result of gravure printing using 350 line plate and paste (3), the conductive pattern has $1.2{\mu}m$ of film thickness and $1.9{\times}10^{-5}{\Omega}{\cdot}cm$ of conductivity.

  • PDF

Noradrenergic Modulation of Spontaneous Inhibitory Postsynaptic Currents in the Hypothalamic Paraventricular Nucleus

  • Lee, Long-Hwa;Chong, Won-Ee;Lee, Ki-Ho;Park, Jin-Bong;Ryu, Pan-Dong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권2호
    • /
    • pp.71-80
    • /
    • 2002
  • Previous studies have suggested that brain stem noradrenergic inputs differentially modulate neurons in the paraventricular nucleus (PVN). Here, we compared the effects of norepinephrine (NE) on spontaneous GABAergic inhibitory postsynaptic currents (sIPSCs) in identified PVN neurons using slice patch technique. In 17 of 18 type I neurons, NE $(30{\sim}100{\mu}M)$ reversibly decreased sIPSC frequency to $41{\pm}7%$ of the baseline value $(4.4{\pm}0.8\;Hz,\;p<0.001).$ This effect was blocked by yohimbine $(2{\sim}20{\mu}M),$ an ${\alpha}_2-adrenoceptor$ antagonist and mimicked by clonidine $(50{\mu}M),$ an ${\alpha}_2-adrenoceptor$ agonist. In contrast, NE increased sIPSC frequency to $248{\pm}32%$ of the control $(3.06{\pm}0.37\;Hz,\;p<0.001)$ in 31 of 54 type II neurons, but decreased the frequency to $41{\pm}7$ of the control $(5.5{\pm}1.3\;Hz)$ in the rest of type II neurons (p<0.001). In both types of PVN neurons, NE did not affect the mean amplitude and decay time constant of sIPSCs. In addition, membrane input resistance and amplitude of sIPSC of type I neurons were larger than those of type II neurons tested (1209 vs. 736 $M{\Omega},$ p<0.001; 110 vs. 81 pS, p<0.001). The results suggest that noradrenergic modulation of inhibitory synaptic transmission in the PVN decreases the neuronal excitability in most type I neurons via ${\alpha}_2-adrenoceptor,$ however, either increases in about 60% or decreases in 40% of type II neurons.