• Title/Summary/Keyword: jump phenomena

Search Result 69, Processing Time 0.019 seconds

Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures (SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상)

  • 이복희;이경옥;백승권
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF

Effects of Surface Radiation on the Unsteady Natural Convection in a Rectangular Enclosure

  • Baek, Seung-Wook;Kim, Taig-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • Numerical solution of the full Navier-Stokes equation as well as the energy equation has been obtained for the unsteady natural convection in a rectangular enclosure. One side wall was maintained at very high temperature simulating fires. Especially the effect of surface radiation was taken into account. While the enclosed air was assumed to be transparent, the internal walls directly interacted one another through the surface radiation. Due to a significant temperature difference in the flow field, the equation of state was used instead of the Boussinesq approximation. It was found that the rapid heating of the adiabatic ceiling and floor by the incoming radiation from the hot wall made the evolution at thermo-fluid field highly unstable in the initial period. Therefore, the secondary cells brought about at the floor region greatly affected the heat transfer mechanism inside the enclosure. The heat transfer rate was augmented by the radiation, resulting in requiring less time for the flow to reach the steady state. At the steady state neglecting radiation two internal hydraulic jumps were clearly observed in upper/left as well as in lower/right comer. However, the hydraulic jump in the lower/right comer could not be observed for the case including radiation due to its high momentum flow over the bottom wall. Radiation resulted in a faster establishment of the steady state phenomena.

A Basic Study on the Crack Arrest Phenomena (균열정지현상에 관한 기초적 연구)

  • 이억섭;김상철;송정일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.112-118
    • /
    • 1990
  • Catastrophic fracture cannot be avoided after cracks(initiated from pre-existing defects) propagate rapidly with speeds comparable to a sound wave velocity of the materials. Preventing catastropic failure, crack arrest fracture toughness defined from dynamic(or kinetic) fracture mechanics point of view has been introduced in determining accurate and/or proper crack arrest fracture toughness of a material. For the past decades, many studies have been carried out to render proper theoretical and experimental backgrounds on the use of the static plain strain crack arrest fracture toughness, $K_{1a}$ (which seems to be a material property). $K_{1a}$ has been used to predict the performance of thick walled structures and has been considered as a measure of the ability of a material to stop a fast running crack. Determination of such a material property is of prime importance to the nuclear reactor pressure vessel and bridge materials industries. However, standards procedures for measuring toughness associated with fast running cracks are yet to exist. This study intends to give insight on the determination of the crack arrest fracture toughness of materials such as polymethylmethacrylate(PMMA), SM45C-steel, and A1 7075-T6. The effects of crack jump lengths and fast crack initiation stress intensity factor on the determination of $K_{1a}$ have been experimentally observed.erved.

정규모드 동역학을 활용한 비선형 진동

  • 박철희
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.6-12
    • /
    • 1997
  • 물리계에서 일어나는 동적 현상들은 선형해석 만으로 설명하기에는 불충분한 점이 많이 있다. 이는 기계구조물과 같은 실제 계의 진동이 기하학적 비선형성, 강성 의 비선형성 또는 경계조건의 비선형성 등의 영향으로 비선형적인 거동을 하기 때문 이다. 비선형 진동을 하는 기계 계는 우리 주변에서 쉽게 찾아 볼 수 있는데, 그 예로써 진자운동을 포함하여 동흡진기, 회전체계, 공작기계의 절삭운동, 건마찰 (dry friction) 관련 기계장치, 치차 및 기차의 바퀴와 레일 간의 접촉에서 볼수 있는 구분적 선형(piecewise linear) 진동계, 충격 진동계 등을 들 수 있다. 비선형 진동 연구는 limit cycle, 준주기운동(quasiperiodic motion), 점프현상(jump phenomena) 등의 인식에서 시작되어, 과거에는 설명이 안되어 회피되 왔던 랜덤(random) 형태의 비주기운동에 대한 연구로 까지 발전하고 있다. 비선형 진동을 다루는데 있어서 정규모드(normal mode)를 이용하는 방법이 있다. 일반적으로 선형계는 선형 정규모드 (linear normal mode)가 존재하는 것과 같이 비선형계에도 이와 유사한 정규모드가 존재한다는 사실이 연구 보고된 바 있다. 비선형계에 존재하는 정규모드는 계의 매개 변수(system parameters)에 따라 그 안정성이 바뀔 수 있으며, 만일 안정한 정규모드 가 어떤 매개변수에서 그 안정성이 바뀐다면 선형이론으로는 설명될 수 없는 새로운 운동이 일어나고 이러한 운동을 분기모드(bifurcation mode)라고 한다. 안정한 정규 모드 및 분기모드를 포함하여 비선형계를 다류는 것을 "정규모드 동역학(normal mode dynamics)"이라고 한다. 정규모드 동역학은 앞에서 언급된 비선형 현상들의 원인규명, 예측, 안정성해석 및 강제진동 해석을 가능하게 한다. 또한 최근에 활발히 연구되고 있는 혼돈운동(chaotic motion)의 해석도 가능하다. 이 글에서는 비선형 진동해석을 위한 정규모드 동역학에 대한 연구동향 및 기본 이론을 살펴 보았고, 그 적용 예를 통하여 실험결과와 비교 고찰 함으로써 정규모드 동역학의 적용성을 서술하여 보았다. 선형이론으로 이해하기 어려운 현상들에 대하여는 비선형의 관점에서 새롭게 접근하 려는 노력이 필요하며 비선형 이론에 대한 연구가 지속적으로 진행되어야 한다. 진행되어야 한다.

  • PDF

Heat Transfer Equation and Finite Element Analysis Considering Frozen Ground Condition the Cyclic Loading (지반의 동결조건을 고려한 열전도 구성방정식과 유한요소해석)

  • Kim, Young-Seok;Kang, Jae-Mo;Hong, Seung-Seo;Kim, Kwang-Jin
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.3
    • /
    • pp.39-45
    • /
    • 2010
  • When the ground temperature drops below $0^{\circ}C$, wet soils expand due to the ice formation in their porous space. This results in frost heave which causes structural stability problems. Frost heave is attributed by several factors such as physical soil properties and heat transfer including pore water phase change. Due to the complex physical phenomena, reliable and verified multi-dimensional numerical models for frost heave problems are still in a research stage. This study presents an efficient and simple method of overcoming numerical problems associated with sudden jump of heat capacity due to the phase change from water to ice in the pore space. This paper proposes heat transfer equation and finite element method when the saturated soils or porous rocks are subjected to freezing. Numerical analyses using the proposed method agree well with the known closed form solution and the laboratory test results.

  • PDF

MULTI-SCALE MODELING AND ANALYSIS OF CONVECTIVE BOILING: TOWARDS THE PREDICTION OF CHF IN ROD BUNDLES

  • Niceno, B.;Sato, Y.;Badillo, A.;Andreani, M.
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.620-635
    • /
    • 2010
  • In this paper we describe current activities on the project Multi-Scale Modeling and Analysis of convective boiling (MSMA), conducted jointly by the Paul Scherrer Institute (PSI) and the Swiss Nuclear Utilities (Swissnuclear). The long-term aim of the MSMA project is to formulate improved closure laws for Computational Fluid Dynamics (CFD) simulations for prediction of convective boiling and eventually of the Critical Heat Flux (CHF). As boiling is controlled by the competition of numerous phenomena at various length and time scales, a multi-scale approach is employed to tackle the problem at different scales. In the MSMA project, the scales on which we focus range from the CFD scale (macro-scale), bubble size scale (meso-scale), liquid micro-layer and triple interline scale (micro-scale), and molecular scale (nano-scale). The current focus of the project is on micro- and meso-scales modeling. The numerical framework comprises a highly efficient, parallel DNS solver, the PSI-BOIL code. The code has incorporated an Immersed Boundary Method (IBM) to tackle complex geometries. For simulation of meso-scales (bubbles), we use the Constrained Interpolation Profile method: Conservative Semi-Lagrangian $2^{nd}$ order (CIP-CSL2). The phase change is described either by applying conventional jump conditions at the interface, or by using the Phase Field (PF) approach. In this work, we present selected results for flows in complex geometry using the IBM, selected bubbly flow simulations using the CIP-CSL2 method and results for phase change using the PF approach. In the subsequent stage of the project, the importance of effects of nano-scale processes on the global boiling heat transfer will be evaluated. To validate the models, more experimental information will be needed in the future, so it is expected that the MSMA project will become the seed for a long-term, combined theoretical and experimental program.

Experimental Investigations on Air Entrainment Through an Air Vent Installed on a Gated Conduit of a Reservoir (저수지 취수시설의 공기관을 통한 공기연행에 대한 실험적 연구)

  • Kang, Min Goo;Park, Young Jin;Kim, Ji Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.149-155
    • /
    • 2013
  • In this study, factors that affect the air entrainment within a closed conduit by air drawn in through an air vent are investigated using a hydraulic scale model, which represents a gated circular conduit system connected to the intake tower of an irrigation reservoir. In addition, using data obtained during the hydraulic experiments, experimental equations are developed to estimate the amount of air drawn in through the air vent. In case of pressurized flow conditions downstream of hydraulic jumps, the relationships between $\frac{Q_a}{Q_w}$ and $Fr_g-1$ of the data form a experimental equation, $\frac{Q_a}{Q_w}=0.0304(Fr_g-1)^{1.0622}$; in case of free surface flow conditions, $\frac{Q_a}{Q_w}=0.0271(Fr_g-1)^{1.8205}$. Comparing two data sets observed under the two flow regimes with the results of previous researchers, patterns of the data sets are similar to the results estimated using the equations presented previously, and this indicates that the quality of the data obtained during the hydraulic experiments is ensured. In addition, it is revealed that air entrainment phenomena in the regions close to air vents are affected by the characteristics of supercritical flows downstream of gates. Finally, it is concluded that the equation developed for pressurized flow conditions can be applied to design of air vents.

A Study of Predictability of VKOSPI on the KOSPI200 Intraday Jumps using different Jump Size and Trading Time (점프발생 강도 및 거래시간에 따른 변동성지수의 KOSPI200 일중 점프 예측력에 관한 연구)

  • Jung, Dae-Sung
    • Management & Information Systems Review
    • /
    • v.35 no.1
    • /
    • pp.273-286
    • /
    • 2016
  • This study investigated the information contents of KOSPI200 Options for intraday big market movement by using minute by minute data. The major findings are summarized as follows; First, big market movement occurred more frequently during 9:00~10:00 and 14:00~14:50. These phenomena reflect market unstability just after opening and near closing. Second, VKSOPI is most closely associated with extreme changes such as KOSPI200 jumps. Third, VKOSPI is showed more predictive power with negative KOSPI200 jumps than KOSPI200 jumps. Fourth, VKOSPI showed predictive power for the positive and negative jumps up to 30 minutes before the jumps occurs. The purpose of this study is to explore the most recent topics in the field of finance, research on market microstructure. This study is an important contribution to investigate intraday information comprehensively in terms of market microstructure effects using the 15-year long-term and the high-frequency data(minute by minute). The results of this study are expected to contribute to detect intraday true jumps, proactive development of market risk indicators, risk management, derivatives investment strategy.

  • PDF

Identifying Three-Dimensional Hydraulic Characteristics of the Sea Region Under Combined Tidal Current and Shock Waves (조류와 충격파가 혼재한 해역의 3차원적 수리특성 분석)

  • Kang, Min Goo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.339-346
    • /
    • 2009
  • In this study, the flow characteristics of the sea region, where tidal current and shock waves are combined, are identified using a three-dimensional numerical model (Princeton Ocean Model, POM). The model is adopted and applied for simulating the flows of the sea region near the open sections during the seadike closure work of Sihwa Seadike which was closed in 1994. The simulation results show that the shock waves with high velocities propagate through the sections toward the inside and outside of the seadike during the periods of the spring and ebb tides, respectively. It is found that the phenomena of flow separation occur near the shock waves; as the shock waves extend to wider zones after passing the sections, their effects on the tidal current become weak. In addition, the longitudinal velocity profiles of the flows are revealed to be affected by the shock waves. For all the simulations, at the ebb tide, the drawdown of the water levels occurs in front of the open section, respectively, especially, hydraulic jump occurs when simulating the case of maximum difference in water level between the inside and outside of the seadike. As a result, it is thought that the flow characteristics of the sea region dominated by shock waves need to be identified employing three-dimensional analysis approach, which is expected to provide the information for ocean engineering works and facility management.