• 제목/요약/키워드: joint structure

Search Result 1,700, Processing Time 0.034 seconds

A Study on Design Parameters Affecting the Stiffness of Center Pillar-Roof Rail Joint (센터필러 -루프레일 결합부의 강성에 영향을 미치는 인자 연구)

  • 이상범;임홍재;이종선
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.1
    • /
    • pp.94-99
    • /
    • 2004
  • The global stiffnesses and vibration characteristics of vehicle structures are mainly influenced by local stiffnesses of the joint structures consisted of complicated thin-walled panels. In this paper, the parametric study for the stiffnesses of the center pillar-roof rail joint of vehicle structure is performed through the linear static analysis. The analysis result shows that the reinforcement panel much affects the joint stiffness of out-plane direction (i.e., z-direction). And also, the flange radius and width of the joint structure much affect the Joint stiffness of out-plane direction. The study shows that vehicle joint stiffnesses can be effectively determined in designing vehicle structure through the parametric study.

Theoretical and experimental modal responses of adhesive bonded T-joints

  • Kunche, Mani Chandra;Mishra, Pradeep K.;Nallala, Hari Babu;Hirwani, Chetan K.;Katariya, Pankaj V.;Panda, Subhransu;Panda, Subrata K.
    • Wind and Structures
    • /
    • v.29 no.5
    • /
    • pp.361-369
    • /
    • 2019
  • The modal frequency responses of adhesive bonded T-joint structure have been analyzed numerically and verified with own experimental data. For this purpose, the damped free frequencies of the bonded joint have been computed using a three-dimensional finite element model via ANSYS parametric design language (APDL) code. The practical relevance of the joint structure analysis has been established by comparing the simulation data with the in-house experimental values. Additionally, the influences of various geometrical and material parameters on the damped free frequency responses of the joint structure have been investigated and final inferences discussed in details. It is observed that the natural frequency values increase for the higher aspect ratios of the joint structure. Also, the joint made up of Glass fiber/epoxy with quasi-isotropic fiber orientation indicates more resistance towards free vibration.

Design of Compliant Hinge Joints inspired by Ligamentous Structure (인대 구조에 기인한 유연 경첩 관절의 설계)

  • Lee, Geon;Yoon, Dukchan;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.237-244
    • /
    • 2019
  • This paper suggests novel types of joint mechanisms composed of elastic strings and rigid bodies. All of the human hinge joints have the articular capsule and a pair of collateral ligaments. These fibrous tissues make the joint compliant and stable. The proposed mechanism closely imitates the human hinge joint structure by using the concept of tensegrity. The resultant mechanism has several characteristics shown commonly from both the tensegrity structure and the human joint such as compliance, stability, lightweight, and non-contact between rigid bodies. In addition, the role and feature of the human hinge joints vary according to the origins of a pair of collateral ligaments. Likewise, the locations of two strings corresponding to a pair of collateral ligaments produce different function and motion of the proposed mechanism. It would be one of the advantages obtained from the proposed mechanism. How to make a joint mechanism with different features is also suggested in this paper.

A Study on the Strength and Failure Mode of Co-cured Composite Joints (동시경화법으로 제조된 복합재료 조인트의 강도 및 파괴모드 연구)

  • Choi, Jin-Ho;Lee, Dae-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.385-392
    • /
    • 1997
  • The joint design and manufacture of the composite structure have become an important research area because the structural efficiency of the composite structure is often determined by its joint not by its basic structure. The co-cured joint is an efficient joint technique because both curing and jointing for composite structures are achieved simultaneously. In this paper, the torque capacities of the co-cured tubular lap joint with and without knurling of the pyamid type were experimentally measure. From the experimental resuts, it was found that the excess resin played a role as an adhesive in the co-cured tubular lap joint whose steel adherends were not knurled. Also, it was found that the torque capacity of the co-cured joint was increased as the knurling size of the pyramid type on the surface of the steel adherend was increased.

A Study on the Joint Element Connection of Joint Element Structure Method (JES 공법의 JOINT ELEMENT 이음부에 관한 연구)

  • 엄기영;박명준
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.133-141
    • /
    • 2002
  • Recently developed JES(Joint Element Structure) Method was researched as a more safe and economic method than other under pass construction method and was applied to many construction sites. The joint element connection of JES Method is the most important factor for the to behavior of structure. The connection of JES method is filled with the mortar, and the steel and mortar of connections produce the same behavior as one material. The results of experience and numerical analysis are following: The maximum internal stress of connection is decided by the end of connection. also, The connection of joint element structure method have sufficient internal stress against fatigue.

Structural Layout Optimization Strategy Considering Assemblage (조립성을 고려한 위상 최적설계법 개발)

  • Choi Guk-Jin;Kim Myung-Jin;Kim Yoon-Young;Jang Gang-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.5 s.248
    • /
    • pp.512-519
    • /
    • 2006
  • In the ground-structure-based topology optimization, beam elements are regarded to be rigidly connected to each other, and joints are assumed to have infinite stiffness. Thus the optimized topology of a structure is obtained according to the assumption of no joint effect, and the resulting structure should be manufactured in one piece if the joint effect is to be excluded as much as possible. The underlying problems are that 1) the performance of the structure might be seriously decreased if the members of the structure are connected through welding or bolting, not manufactured in one piece, and 2) the topology of the structure will be changed if the joint effect is taken into account. In the paper, the assemblage issue is considered on topology optimization, and a new formulation based on the joint stiffness-varied ground beam structure is developed. Joints of a beam structure are modeled by elastic spring elements whose stiffnesses are controlled by design variables during the optimization.

An Experimental study on the Construction Standard for Sealer of Injection Type for Leakage Maintenance (누수보수용 주입형 실링재의 시공 기준에 관한 실험적 연구)

  • Lim Min-Chan;Cho Il-Kyu;Seon Yun-Suk;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.51-54
    • /
    • 2005
  • The concrete structure hasn't perfect waterproofing performance but if it doesn't have a joint part that could isolate a permeability. Concrete structure(communication tunnel and underground structure) has an expansion joint and construction joint. There are a lot of joint type after construction or expansion, shrinkage, vibration, over load, performance of decline etc.. they offer a water of way by variety change. In this reason, It carries in effect a waterproofing work for the concrete structure of waterproofing. but the structure has a behavior that cause a problem by waterproofing layer of damage, heaving phenomenon, temperature of shrinkage. In this study, we will estimate a field of application for Sealer of injection type for leakage maintenance of construction standard on the waterproofing performance.

  • PDF

A Study on the Identification of the joint's Stiffness of a Stucture by Sensitive Analysis Method (감도해석법에 의한 구조물의 결합부 강성 산출에 관한 연구)

  • 박석주;왕지석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.60-66
    • /
    • 1992
  • In most cases a structure consists of the assembly of some substructures, we assemble them with various joints, and the structure is fixed to a foundation through mounts. In case of the structure with rigid joints like welding, the Finite Element Mothod could be easily used to analyize the structure's characteristics, but in case of the structure with elastic joints like bolts or rivets, it might be difficult to analyize it by taking account of joint's rigidities, with the conventional method. This paper proposes the method to identify the joint rigidities by the Sensitive Analysis Method and the Optimization Techniques. And the proposed method applied to identify the rigidities of 4 bolts to combine 2 plates(500mm long, 100mm wide, 3.15mm thich). The analized results were well coincident with the experimental results. To confirm the reliability 0 the rigidities identified, another trial was done for the stucture to combine other 2 plates with same joints. The results were good too. This paper is proposin the identifying method of the joint rigidity of a structure, and it could be used for the data base of the joint rigidity and for the guidance to select joint stiffness.

  • PDF

Impacts of Capital Structure on Business Efficiency of Listed Joint Stock Commercial Banks in Vietnam Stock Market

  • DOAN, Quyen Thuc;HO, Thu Thi Hoai;DOAN, Quynh Huong
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.8
    • /
    • pp.99-108
    • /
    • 2022
  • This study aims to examine the influence of capital structure on the business efficiency of joint stock commercial banks listed on the Vietnamese stock market. The article uses data collected from the financial statements of 15 prominent joint-stock commercial banks out of 27 joint-stock commercial banks listed in Vietnam from 2011 to 2021. The research uses E-view software in quantitative analysis to build regression models to determine the relationship and the impact of capital structure factors on the business efficiency of listed joint stock commercial banks. Research results show that ROA is affected by 2 variables of capital structure. It is the sum of customer deposits to total assets and total liabilities to total equity. Total debt to total equity and total customer deposits to total assets both have a negative effect on ROA. For the regression results of ROA with all control variables, the control variables have a positive relationship with the dependent variable. The article has provided recommendations based on the research findings to determine the proper capital structure. Managers must solve the outstanding amount of mobilized capital in previous years, combined with the bad debt handling activities that have arisen.

Strength Estimation of T-joint Area of Composite Housing of Medium Range Surveillance Radar (중거리급 탐색레이더 복합재 하우징의 T-joint 영역 구조 강도 평가)

  • Kwon, Min-Sang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.149-158
    • /
    • 2008
  • This article provides strength estimation of T-joint area which made of composite material. Inner and outer structures of medium range surveillance radar are all made of sandwich structure which is made with composite material(CFRP) and aluminum honeycomb core. Since the radar is voluminous and has very complex inner structure, the whole structure cannot be made as one piece. Therefore, usage of T-joints is inevitable. Since some of stress concentration areas were located around T-joint area, series of strength estimations were conducted. Three different configurations were tested to improve mechanical properties(primarily on strength). The results show an improvement on strength to meet calculated strength on stress concentrated T-joint area.