• Title/Summary/Keyword: joint resistance

Search Result 569, Processing Time 0.028 seconds

Chloride Diffusion Coefficients in Cold Joint Concrete with GGBFS (고로슬래그 미분말을 혼입한 콜드조인트 콘크리트의 염화물 확산계수)

  • Oh, Kyeong-Seok;Mun, Jin-Man;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.44-49
    • /
    • 2016
  • Among the deteriorating agents, chloride ion is reported to be one of the most harmful ions due to its rapid diffusion and direct effect on steel corrosion. Cold joint which occurs in mass concrete placing is vulnerable to shear resistance and more severe deterioration. The paper presents an quantitative evaluation of chloride diffusion coefficient in OPC(Ordinary Portland Cement) and GGBFS(Ground Granulated Blast Furnace Slag) concrete containing cold joint. GGBFS concrete shows $6.6{\times}10^{-12}m^2/sec$ which is almost 30% level of OPC concrete results and the trend is repeated in the case of cold joint concrete. Compared with OPC concrete, GGBFS concrete is evaluated to have better resistance to chloride penetration, showing 0.30 times of chloride diffusion coefficient in concrete without cold joint 0.39 times with cold joint, respectively.

Experimental Study on Interface Shear Strength of Concrete in Vertical Construction Joint (콘크리트 수직시공이음 접합면의 전단강도에 대한 실험적 연구)

  • Kim, Ook-Jong;Kim, Young-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.125-129
    • /
    • 2004
  • In masive concrete placement, cracking problem due to hydration heat is frequently encountered. One of measure to solve this problem is to make a construction joint. However, it is cumbersome to make it by chipping the surface of joint. In this study, push-out test for 18 specimens was conducted to compare the interface shear strength of consturction joints whose surfaces were prepared with three methods; chipping, rib-lath, folded rib-lath. Compared to the specimens made with conventional surface chipping, those with rib-lathe showd excellent preformance increasing shear resistance capacity and the role of shear key conceived by folding rib-lath played important role in enhancing shear resistance.

Shrinkage and crack characteristics of filling materials for precast member joint under various restraint conditions

  • Lim, Dong-Kyu;Choi, Myoung-Sung
    • Advances in concrete construction
    • /
    • v.14 no.2
    • /
    • pp.139-151
    • /
    • 2022
  • Filling materials poured into precast member joint are subjected to restraint stress by the precast member and joint reinforcement. The induced stress will likely cause cracks at early ages and performance degradation of the entire structure. To prevent these issues and design reasonable joints, it is very important to analyze and evaluate the restrained shrinkage cracks of filling materials at various restraint conditions. In this study, a new time zero-that defines the shrinkage development time of a filling material-is proposed to calculate the accurate amount of shrinkage. The tensile stresses and strengths at different ages were compared through the ring test (AASHTO PP34) to evaluate the crack potential of the restrained filling materials at various restraint conditions. The mixture which contained an expansive additive and a shrinkage reducing agent exhibited high resistance to shrinkage cracking owing to the high-drying shrinkage compensation effect. The high-performance, fiber-reinforced cement composite, and ultra-high-performance, fiber-reinforced cement composite yielded very high resistance to shrinkage and cracking owing to the pull-out property of steel fibers. To this end, multiple nonlinear regression analyses were conducted based on the test results. Accordingly, a modified tensile stress equation that considered both the geometric shape of the specimen and the intrinsic properties of the material is proposed.

Fire resistance assessment in construction joint of precast fireproof duct slab (프리캐스트 방식 내화풍도슬래브 시공조인트부의 화재저항성능 평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Lee, Chulho;Kim, Se Kwon;Kim, Tae Kyun;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.5
    • /
    • pp.359-370
    • /
    • 2021
  • Duct slabs, which are used to build ventilation facilities in underground spaces with transverse ventilation system, need to secure fire resistance according to longitudinal and heavy vehicle traffic of tunnels. This study measured the temperature change at the construction joint of the precast fireproof duct slab which integrates fire resistance material and duct slab under the RWS fire scenario. As a result, it was confirmed that if there is no reinforcement of the construction joint, damage will occur in concrete inside the construction joint, leading to damage to the fireproofing layer. On the other hand, when one side of the construction joint was reinforced with fireproofing materials, it showed more than three times the fire resistance performance compared to when there was no reinforcement. At this time, cross-sectional losses of concrete and fireproofing layer were shown in blocks without reinforcement, but no damage was seen in the reinforced blocks.

Transverse Concinement and Slab Effect on Shear Behavior of Beam-Column Connection (보-기둥 접합부의 전단거동에 대한 슬래브 및 횡구속 영향)

  • 장극관;서대원;방세용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.419-422
    • /
    • 1999
  • This study was intended to investigate the cyclic behavior of high strength concrete beam-column connection. Four assemblies were designed 2/3 scale beam-column-slab joint and tested. The obtained results are follows. 1) The transverse beams increase the shear resistance and ductility of joint, 2) The slab was contributed to increase of the flexural capacity of the beam, but was not contributed to increase the joint ductility under lateral loads.

  • PDF

Joint Behavior and Wind Resistance Characteristics of the Composite Waterproof Method in Which the Sheet Layer is Partially Attached with Perforated Film and the Joint is FRP-Treated (타공필름에 의한 부분절연과 FRP로 조인트부를 강성접착한 복합방수공법의 조인트 거동 및 내풍압 특성)

  • Choi, Sung-Min;Kwon, Yong-Hwa
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.85-86
    • /
    • 2023
  • This study confirmed the improvement of the Composite Waterproof Method in which the sheet layer is partially attached with perforated film and the joint is FRP-treated.

  • PDF

Properties of Butt Joint in $Nb_{3}$Sn Conductors with change of Surface Pressure (접촉 면압에 따른 $Nb_{3}$Sn 도체의 Butt 접합부 특성)

  • 이호진;김기백;김기만
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.253-255
    • /
    • 2002
  • Since a butt Joint is smaller than a lap type joint, it is expected to have smaller AC losses. The butt joint is produced by the diffusion bonding of the contacting surface under pressured and heated condition. It is important to find robust joining conditions, because butt joint has small contact area and has the shape by which the quality of bonding is hard to be checked. In this research, the loading pressure is considered as the joining parameter to find optimum joining condition. The DC resistance of the joint may be changed by the surface pressure during joining process, because the superconducting strands near the contact surface are failed by large plastic deformation. The range from 10 MPa to 18 MPa is expected optimum surface pressure in the conditions of 1 hour heating time and $750^{\circ}C$ temperature in the vacuum furnace.

  • PDF

Structural Behavior of Beam-Column Joints Consisting of Composite Structures

  • Lee, Seung-Jo;Park, Jung-Min;Kim, Wha-Jung
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.111-120
    • /
    • 2002
  • This study proposes a joint model consisting of different types of members as a new structural system, and then investigates the resulting structural behavior. The joint model consists of a concrete-filled steel tube column (CFT) together with a steel reinforced concrete at the end plus reinforced concrete beam at the center. For comparison, two other joint models were designed, that are, a CPT with a reinforced concrete beam, and a CFT with a steel reinforced concrete at the end plus steel concrete beam at the center, then their joint capacity and rigidity, energy absorption capacity, etc., were all investigated. From the results, the CFT column with a steel reinforced concrete at the end plus steel concrete beam at the center was outstanding in terms of its capacity and rigidity. The results of this analysis demonstrate that an adequate connection type and reinforcement method with different materials of increasing the rigidity, thereby producing a capacity improvement along with protection from pre-fractures.

  • PDF

Seismic Assessment of Shear Capacity of RC Beam-Column Joints Without Transverse Re-bars (내진성능평가시 횡보강근이 없는 RC 보-기둥 접합부의 전단내력 평가)

  • Lee, Young Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.249-259
    • /
    • 2019
  • To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.