• 제목/요약/키워드: joint resistance

검색결과 569건 처리시간 0.034초

직접전단시험모델에 의한 뿌리말뚝의 탄소성조인트 유한요소해석 (Elasto-plastic Joint Finite Element Analysis of Root-pile Using the Direct Shear Test Model)

  • 한중근
    • 한국환경복원기술학회지
    • /
    • 제5권4호
    • /
    • pp.19-30
    • /
    • 2002
  • The stability of slope using root-pile like to the reinforcements is affected by the interaction behavior mechanism of soil-reinforcements. Through the studying on the interaction in joint of its, therefore, the control roles can be find out in installed slope. In study, the stress level ratio based on the insert angle of installed reinforcements in soil used to numerical analysis, which was results from the duty direct shear test in Lab. The maximum shear strain variation on the reinforcements was observed at insert angle, which was approximately similar to the calculated angle based on the equation proposed by the Jewell. The elasto-plastic joint model on the contact area of soil-reinforcements was presumed, the reinforced soil assumed non-linear elastic model and the reinforcements supposed elastic model, respectively. The finite element analysis of assumed models was performed. The shear strain variation of non-reinforced state obtained by the FEM analysis including elasto-plastic joint elements were shown the rationality of general limit equilibrium analysis for the slope failure mode on driving zone and resistance zone, which based on the stress level step according to failure ratio. Through the variation of shear strain for the variation of inserting angle of reinforcements, the different mechanism on the bending and the shear resistance of reinforcements was shown fair possibility.

고온초전도 더블 팬케이크 코일들 사이의 접합 방법 (A Joining Method between HTS Double Pancake Coils)

  • 손명환;심기덕;김석호;김해종;배준한;이언용;민치현;성기철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.633-639
    • /
    • 2006
  • High temperature superconductor (HTS) winding coil is one of the key component in superconducting device fabrication. Double-pancake style coils are widely used for such application. High resistance between pancake coils greatly affects the machine design, operating condition and thus the stability. In order to reduce such resistance, experimentalists are looking for efficient and damage free coil connecting methods. In this respect, here we proposed parallel joining method to connect the coils. This is to do crossly joining with HTS tapes on two parallel HTS tapes. Joint samples between two parallel HTS tapes were prepared by using HTS tapes and current-voltage (I-V) characteristic curves were investigated at liquid nitrogen temperature i.e., 77.3 K. A 20 cm length joint connected between two parallel HTS tapes shows $32.5n{\Omega}$, for currents up to 250 A. A small HTS magnet, having two double pancake sub-coils connected together through new parallel joint method was fabricated and their current-voltage (I-V) characteristic curve was investigated. At 77.3K, critical current(Ic) of 97 A and resistance of $55n{\Omega}$ for currents upto 130 A were measured. At operating current 86 A lower than Ic, Joule heats generated in whole magnet and at joint region between sub-coils were 226 mW and 0.4 mW, respectively. Low Joule heat generation suggests that this joining method may be used to fabricate HTS magnet or windings.

The effects of elbow joint angle and resistance point on muscle activation of the contralateral shoulder muscles while performing the ulnar thrust PNF pattern exercise

  • Yeo, Bok-gi;Han, Dong-wook
    • 대한물리의학회지
    • /
    • 제10권3호
    • /
    • pp.101-108
    • /
    • 2015
  • PURPOSE: This study researched the effects of the changes of elbow joint angle and of arm position in PNF pattern on muscle activation of the contralateral shoulder muscles while performing PNF pattern exercise. METHODS: The research subjects were 16 male physical therapists who had no neuromuscular or neurological disorders. To measure the muscle activation of the contralateral shoulder muscles, EMG electrodes were attached to the muscle valley of the middle and posterior areas of the deltoid and triceps muscles of the arm. Muscle activation while performing the ulnar thrust PNF pattern exercise was measured with the elbow joint positioned at angles of $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$. Resistance points were at the initial, middle, and end ranges of PNF pattern exercise. RESULTS: Muscle activation of the middle and posterior portions of the deltoid muscle increased significantly according to the changes of elbow joint angle. In each resistance point the middle range was significantly higher than at other points. A significant difference on muscle activation was demonstrated throughout each range depending on the type of muscle. Muscle activation of the middle and posterior portions of the deltoid muscle was higher than muscle activation of the triceps. CONCLUSION: The results of this study demonstrate that the PNF pattern exercising method used in this study is a selective exercising method focusing on the deltoid muscle over the triceps muscle. In order to increase the muscle strength to the maximum level, it is necessary to provide the maximum level of resistance in the middle range of the elbow joint.

세라믹/금속접합재의 열사이클피로에 따른 접합계면의 잔류응력분포 특성 (Singular Stress Field Analysis and Strength Evaluation in Ceramic/.Metal Joints)

  • 박영철;김현수;허선철;강재욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.709-713
    • /
    • 1996
  • The ceramic has such high qualities as light weight, abrasion resistance, heat resistance compared with metal, but since it is breakable, it can't be used as structural material and it is desirable to joining metal which is full of toughness, but, according as the ceramic/metal joint is executed at high temperature, the joint residual stress develops near the joint sides in the process of cooling the high temperature down to the suitable temperature due to difference of the thermal expansion coefficient between ceramic and metal, and the joint residualstress lowers the fracture strength. In this study, to ensure security and improvement of bending strength, 1 studies on see distribution shape of residual stress according to high thermal cycle, and the influnence of theraml cycle and distribution shape of residual stess on joint-strength.

  • PDF

전통목구조 시스템의 도리방향 골조의 횡저항 성능에 대한 실험 (Experiment of Lateral Load Resistance of Dori-Directional Frame in Traditional Wood Structure System)

  • 이영욱;홍성걸;김남희;정성진;황종국;배병선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.241-246
    • /
    • 2007
  • The capacity of a lateral load resistance of a joint with Jangbu-connection of Dori-directional frame in traditional wood structure system was studied, through experiments of 1/2 scaled and T-shaped 7 subassemblies of joint of Dori-directional frame for Deawoongjeon of Bongjungsa. From the experiment, it was shown that the capacity of a lateral load resistance was influenced by the vertical load confining joint and not influenced by the number of Chok and the depth of Changbang, And lateral load resistance mechanism is developed by the restraint between the vertical load and the contacting edge of column; if structure is pushed to the left, the top-right end of Pyeongju contacts with Changbang and left Changbang loses the contacts with Pyeongju and therefore only right Changbang can resist to lateral load.

  • PDF

저항업셋 용접법을 이용한 Zr-4 End Cap용접부의 특성에 관한 연구 (A Study on the Characteristics of Zr-4 End Cap Welded Joints Using Resistance Upset Welding)

  • 박철주;김형수;이영호;강원석
    • Journal of Welding and Joining
    • /
    • 제10권4호
    • /
    • pp.240-249
    • /
    • 1992
  • The objective of this study is to investigate the characteristics of welded joints on the Zircaloy-4 resistance upset welding for HWR(Heavy Water reactor)fuel rods. To estimate the characteristics of welded joints, the various tests were performed on the test coupons systematically with a wide range of each welding parameters in terms of a tensile test, burst test, knoop hardness test and metallography. Major results obtained in this study are as follows: 1. The tube and machined with 120.deg. projection was the reliable weld joint design for the nuclear fuel rod end cap welding. 2. As the weld current and the amount of upset increased linearly with increasing welding main heat input, it could make an estimate of their variation in accordance with the phase shift control. 3. It was found that an increase in squeeze force has an effect on the upset contour of welded joint because the amount of upset were increased by the change of squeeze force.

  • PDF

Investigation of soldered low-resistance joints for coated conductors

  • Balashov, N.N.;Degtyarenko, P.N.;Ivanov, S.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.25-27
    • /
    • 2015
  • The experimental investigation of resistance and thermal impacts stability of coated conductor joints has been carried out. We measured resistances of solder layers with the thicknesses ca. 10, 20, 30 and $40{\mu}m$ and additionally studied their stability against thermal impacts. The obtained results show a high quality of this joints and their applicability, e.g., for design of current leads in various superconductive energy applications.

Effects of the Abduction Resistance of the Hip Joint during Bridge Exercise in Patients with Chronic Back Pain: A Cross-Over Study

  • Kim, Dong-Hyun;Kim, Kyu-Ryeong;Bae, Chang-Hwan;Kim, Myoung-Kwon
    • 대한물리의학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2022
  • PURPOSE: This study examined the effects of the resistance levels on the muscle activities around the hip and spine during bridge exercise with hip abduction resistance in patients with chronic back pain. METHODS: A cross-over study design was used. Twenty subjects with low back pain were enrolled in this study. The subjects performed bridge exercises with hip abduction resistances (20 mmHg, 40 mmHg, and 60 mmHg). A Narrow Sling was used to provide resistance. Surface electromyography was used to measure the activity of the erector spinae, biceps femoris, gluteus maximus, and gluteus medius. RESULTS: The muscle activity of the gluteus maximus and gluteus medius increased significantly with increasing resistance levels. There was a significant difference in the muscle activity of the biceps femoris with a resistance level between 20 mmHg and 40 mmHg, but there was no significant difference in the other resistance levels. There was no significant difference according to resistance level in the erector spinae. The muscle activity ratios of the gluteus medius/erector spinae and gluteus maximus/erector spinae increased significantly with increasing resistance strength. CONCLUSION: The different levels of abduction resistance for hip abduction during bridge exercise will help activate the gluteus maximus selectively in patients with chronic back pain.

Characteristics of joint resistance with different kinds of HTS tapes for heater trigger switch

  • Lee, Jeyull;Park, Young Gun;Lee, Woo Seung;Jo, Hyun Chul;Yoon, Yong Soo;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.32-35
    • /
    • 2014
  • Recently, many researches on the system of superconducting power supply and superconducting magnetic energy storage (SMES) using high temperature superconducting (HTS) tapes has been progressed. Those kinds of superconducting devices use the heater trigger switches that have a control delay problem at moments of heating up and cooling down. One way to reduce the time delay is using a different HTS tape at trigger part. For example, HTS tape having lower critical temperature can reduce time delay of heating up and heating down stage for heater trigger operation. This paper deals with resistances joint with different kinds of HTS tapes which have different properties to verify usefulness of the suggested method. Three kinds of commercial HTS tapes with different specifications are selected as samples and two kinds of solders are used for comparison. Joint is performed with temperature and pressure controllable joint machine and the joint characteristics are analyzed under the repeatable conditions.

The Effects of Bridge Exercise with One Hip Joint Adduction on Trunk Muscle Thickness

  • Park, Jae-Cheol;Lee, Dong-Kyu
    • The Journal of Korean Physical Therapy
    • /
    • 제32권6호
    • /
    • pp.354-358
    • /
    • 2020
  • Purpose: This study aimed to verify the effects of bridge exercise with resistance to one hip joint adductor muscle on the thickness of external and internal oblique abdominal muscles, transversus abdominis muscle, and erector spinae muscle. Methods: The subjects were divided into two exercise groups: 15 for Bridge Exercise Group (BEG) and 15 for One Hip joint Adduction Bridge Exercise Group (OHABEG). The study used an ultrasonic instrument to measure trunk muscle thickness. OHABEG performed a bridge exercise with one hip Joint adduction. BEG performed a bridge exercise without resistance. Results: The external oblique abdominal, internal oblique abdominal, and the transversus abdominis muscles showed a significant increase by period and time in intra-group interactions (p<0.05), while there was no significant difference in inter-group changes (p>0.05). The erector spinae muscle had a significant increase in each period (p<0.05) but no significant difference in time, intra-group interactions, and in inter-group changes (p>0.05). Conclusion: These results demonstrated that bridge exercise with one hip joint adduction had positive effects on trunk muscle thickness. These results confirm that a bridge exercise with one hip joint adduction has a positive effect on the muscle thickness of trunk, suggesting the possibility of using it as a rehabilitation treatment for a lumbar stabilization exercise and as a basic data.