• 제목/요약/키워드: joint resistance

검색결과 571건 처리시간 0.029초

고전류 스트레싱하에서 의 ACF플립칩의 신뢰성 해석에 관한 연구

  • 권운성;백경욱
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 춘계 기술심포지움 논문집
    • /
    • pp.247-251
    • /
    • 2002
  • In this paper the maximum current carrying capability of ACAs flip chip joint is investigated based on two failure mechanisms: (1) degradation of the interface between gold stud bumps and aluminum pads; and (2) ACA swelling between chips and substrates under high current stress. For the determination of the maximum allowable current, bias stressing was applied to ACAs flip chip joint. The current level at which current carrying capability is saturated is defined as the maximum allowable current. The degradation mechanism under high current stress was studied by in-situ monitoring of gold stud bump-aluminum pad ACA contact resistance and also ACA junction temperature at various current level. The cumulative failure distributions were used to predict the lifetime of ACAs flip chip joint under high current stressing. These experimental results can be used to better understand and to improve the current carrying capability of ACA flip chip joint.

  • PDF

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • 제8권4호
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

플립 칩 BGA에서 2차 레벨 솔더접합부의 신뢰성 향상 (The Improvement of 2nd Level Solder Joint Reliability fur Flip Chip Ball Grid Array)

  • 김경섭;이석;장의구
    • Journal of Welding and Joining
    • /
    • 제20권2호
    • /
    • pp.90-94
    • /
    • 2002
  • FC-BGA has advantages over other interconnection methods including high I/O counts, better electrical performance, high throughput, and low profile. But, FC-BGA has a lot of reliability issues. The 2nd level solder joint reliability of the FC-BGA with large chip on laminate substrate was studied in this paper. The purpose of this study is to discuss solder joint failures of 2nd level thermal cycling test. This work has been done to understand the influence of the structure of package, the properties of underfill, the properties and thickness of bismaleimide tiazine substrate and the temperature range of thermal cycling on 2nd level solder joint reliability. The increase of bismaleimide tiazine substrate thickness applied to low modulus underfill was improve of solder joint reliability. The resistance of solder ball fatigue was increased solder ball size in the solder joints of FC-BGA.

Ductility analysis of bolted extended end plate beam-to-column connections in the framework of the component method

  • Girao Coelho, Ana M.;Simoes da Silva, Luis;Bijlaard, Frans S.K.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.33-53
    • /
    • 2006
  • The rotational behaviour of bolted extended end plate beam-to-column connections is evaluated in the context of the component method. The full moment-rotation response is characterized from the force-deformation curve of the individual joint components. The deformability of end plate connections is mostly governed by the bending of the column flange and/or end plate and tension elongation of the bolts. These components form the tension zone of the joint that can be modelled by means of "equivalent T-stubs". A systematic analytical procedure for characterization of the monotonic force-deformation behaviour of individual T-stub connections is proposed. In the framework of the component method, the T-stub is then inserted in the joint spring model to generate the moment-rotation response of the joint. The procedures are validated with the results from an experimental investigation of eight statically loaded extended end plate bolted moment connections carried out at the Delft University of Technology. Because ductility is such an important property in terms of joint performance, particularly in the partial strength joint scenario, special attention is given to this issue.

Seismic behavior and strength of L-shaped steel reinforced concrete column-concrete beam planar and spatial joints

  • Chen, Zongping;Xu, Deyi;Xu, Jinjun;Wang, Ni
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.337-352
    • /
    • 2021
  • The study presented experimental and numerical investigation on the seismic performance of steel reinforced concrete (SRC) L-shaped column- reinforced concrete (RC) beam joints. Various parameters described as steel configuration form, axial compressive ratio, loading angle, and the existence of slab were examined through 4 planar joints and 7 spatial joints. The characteristics of the load-displacement response included the bearing capacity, ductility, story drift ratio, energy-dissipating capacity, and stiffness degradation were analyzed. The results showed that shear failure and flexural failure in the beam tip were observed for planar joints and spatial joint, respectively. And RC joint with slab failed with the plastic hinge in the slab and bottom of the beam. The results indicated that hysteretic curves of spatial joints with solid-web steel were plumper than those with hollow-web specimens. The capacity of planar joints was higher than that of space joints, while the opposite was true for energy-dissipation capacity and ductility. The high compression ratio contributed to the increase in capacity and initial stiffness of the joint. The elastic and elastic-plastic story deformation capacity of L-shaped column frame joints satisfied the code requirement. A design formula of joint shear resistance based on the superposition theory and equilibrium plasticity truss model was proposed for engineering application.

탄력밴드저항운동이 장기요양 방문간호 이용 여성노인의 체력, 일상생활수행능력, 낙상효능감 및 삶의 질에 미치는 효과 (Effects of Elastic Band Resistance Exercise on Physical Fitness, Activities of Daily Living, Falls Efficacy, and Quality of Life Among Older Women Receiving Home Nursing)

  • 조정옥;안옥희
    • 근관절건강학회지
    • /
    • 제27권2호
    • /
    • pp.71-80
    • /
    • 2020
  • Purpose: This thesis study aimed to examine the effects of elastic-band resistance exercise on physical fitness, activities of daily living (ADLs), falls efficacy, and quality of life among older women receiving home nursing care under long-term care insurance. Methods: We used an equivalent control group pre-test/post-test design. We assigned older women at the nursing care center J to the experimental group (n=21), and older adult women at the nursing care center H to the control group (n=21). The experimental group engaged in an elastic band resistance exercise twice per week from February 18 to April 12, 2019. Results: There were significant differences in the Short Physical Performance Battery score (t=4.15 p<.001), left grip strength (t=0.57, p<.569), right grip strength (t=1.38 p<.177), flexibility test scores (t=2.34, p<.024), ADLs (t=6.86, p<.001), falls efficacy (t=5.16, p<.001), and quality of life (t=3.87, p<.001). Grip strength was increased slightly in the experimental group, but the increase was not significant. Conclusion: Elastic band resistance exercise is an effective nursing intervention to enhance physical fitness, flexibility, ADLs, falls efficacy, and quality of life among older women receiving home nursing care under long term care insurance.

살충제 저항성 배추좀나방 방제를 위한 Bifenthrin과 Prothiofos 혼용의 연합작용 (Joint Toxic Action of Bifenthrin and Prothiofos Mixture for the Control of Insectivcide-Resistant Diamondback Moth, Plutella xylostella L.)

  • 정부근;강수웅;추호렬
    • 한국응용곤충학회지
    • /
    • 제36권1호
    • /
    • pp.105-110
    • /
    • 1997
  • Fenvalerate, cypermethrin, furathiocarb 및 prothiofos에 대해 각각 581, 18, 19, 11배의 저항성을 보인 진주계통과 fenvalerate와 furathiocarb에 대해 각각 38배와 9배의 저항성을 나타내고 있는 함양.서상계동을 bifenthrin과 prothiofos의 혼합조합으로 방제하기 위해 실내 엽침지법과 포장방제시험을 수행하였다. Bifenthrin 1EC와 prothiofos 50EC을 1:50으로 혼합하여 실내엽침지법으로 처리하였을 때 공력계수가 273.2로 최고점에 도달한 후 급격히 감소하는 양상을 보였다. 침지법에서 가장 효과적이었던 혼용비율의 조합을 함양.서상현지 농가에서 실증시험을 수행한 결과, 처리구에서 처리약량을 절반으로 줄였음에도 배추좀나방의 방제효과가 농가관행구와 마찬가지로 우수하였다. 또한 이 조합은 여러가지 대표적인 살충제에 대해 높은 저항성을 나타내고 있는 진주지역계통에 대해서도 합리적인 농약혼합으로 저항성문제에 적절히 대처할 수 있음을 보여주었다.

  • PDF

Effects of Elastic Resistance Training on Biomechanical Ability in College Taekwondo Athletes

  • Hyun Suk Yang;Jonggeun Woo;Jiheon Hong
    • The Journal of Korean Physical Therapy
    • /
    • 제35권5호
    • /
    • pp.132-138
    • /
    • 2023
  • Purpose: This study compared the effects of the elastic resistance and general training for college Taekwondo athletes, and investigated the biomechanical ability and lower extremity function according to the movement speed of the knee joint. Methods: Twenty university student Taekwondo athletes participated voluntarily in this study. The subjects performed general resistance training for four weeks, followed by elastic resistance training for another four weeks. The biomechanical parameters during the fast and slow isokinetic conditions, Y-balance ability, and vertical jump ability were measured three times: before training, after general resistance training, and after elastic resistance training. Statistical analysis was performed under isokinetic conditions and the intervention effect. Results: The biomechanical ability differed significantly between fast and slow isokinetic conditions (p<0.05). An analysis of the training method revealed a significant difference in the maximum knee extension speed and the posterior-lateral direction of the Y-balance test (p<0.05). Conclusion: Elastic resistance training had a more positive effect on the functional task performance than biomechanical factors related to muscular strength compared to general resistance training. In addition, speed-related knee biomechanical information of subjects with strong physical abilities could be utilized in sports physiotherapy.

바벨 백 스쿼트 시 운동 속도 조건에 따른 하지근 활성도 및 무릎 관절의 부하량 비교 (Comparison of Lower Extremity Muscle Activity and Knee Joint Load according to Movement Speed Conditions during the Barbell Back Squat)

  • Moon-Seok Kwon;Jae-Woo Lee
    • 한국운동역학회지
    • /
    • 제34권1호
    • /
    • pp.25-33
    • /
    • 2024
  • Objective: The purpose of this study was to compare the lower extremity muscle activity and knee joint load according to movement speed conditions during the barbell back squat. Method: Nine males with resistance training experience participated in this study. Participants performed the barbell back squat in three conditions (Standard, Fast, and Slow) differing movement speed. During the barbell back squat, muscle activity of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), biceps femoris long head (BFL), semitendinosus (ST), gluteus maximus (GM), gastrocnemius (GCN), and tibialis anterior (TA) was collected using an 8 channel wireless EMG system. The peak flexion angle of the lower extremity joints and the peak resultant joint force in each direction of the knee joint were calculated using eight motion capture cameras and ground reaction force plates. This study was to used the Friedman test and the Wilcoxon signed rank test, to compare lower extremity muscle activity and peak resultant joint force at knee joint according to movement speed conditions during the barbell back squat, and the statistical significance level was set at .01. Results: In the downward phase of the barbell back squat, the RF and TA showed the higher muscle activity in the fast condition, and in the upward phase, RF, VL, VM, BFL, ST, GM, and TA showed the higher muscle activity in the fast condition. As a results, analyzing of the load on the knee joint, in the downward phase, and in the upward phase, the higher peak compressive force of the knee joint was showed in the fast condition. Conclusion: The barbell back squat with fast movement speed was more effective due to increased muscle activity of lower extremity, but one must be careful of knee joint injuries because the load on the knee joint may increase during the barbell back squat with fast movement speed.