• 제목/요약/키워드: joint protection

검색결과 172건 처리시간 0.026초

A Study on the Differences in the Cognition of the Visitor-Reservation System: Focused on Uiryeong-Gil Area in Bukhansan National Park

  • Sim, Kyu-won;Choe, Yunseon;Jang, Jin;Nam, Seungmin
    • Journal of Forest and Environmental Science
    • /
    • 제37권1호
    • /
    • pp.69-78
    • /
    • 2021
  • This study aims to verify a difference between the years 2014 and 2019 of Uiryeong-Gil, which is operated by the Visitor-Reservation System, in terms of the cognition of system, operational effectiveness, and behavioral intention. The analysis is as follows. First, among the overall cognition of the Visitor-Reservation System, the satisfaction from - prevention for safety for accident, expansion to other parks, number of visitor restriction, and satisfaction with reservation method - increased compared to 2014. Second, among the effects of the Visitor-Reservation System operation, satisfaction shows differences in year-to-year levels in terms of resource protection, resource damage mitigation efficiency, natural experience opportunity, comfort of visit-environment, and prevention of illegal activities. Third, the analysis of the differences in the behavior of the Visitor-Reservation System showed that the satisfaction of visitors, revisit intention, and overall satisfaction differed per year. The results of this study are meaningful in that the Visitor-Reservation System is no longer the restriction, but the change in cognition for the protection of ecosystems and sustainable visiting in order to expand the Visitor-Reservation System into a sustainable policy.

타설 경계면을 고려한 철도교 콘크리트궤도 전단키의 전단 거동 해석 (Analysis of Shear Behavior of Shear Key for Concrete Track on Railway Bridge Considering Construction Joint)

  • 이성철;강윤석;장승엽
    • 한국철도학회논문집
    • /
    • 제19권3호
    • /
    • pp.341-350
    • /
    • 2016
  • 철도교량 구간의 콘크리트 궤도는 교량 상부구조의 움직임에 효과적으로 대응할 수 있도록 설계되어야 한다. 이를 위해 일반적으로 전단키로 명명되는 전단키를 교면 보호 콘크리트층(PCL) 위에 일정 간격으로 설치하여 그 위에 궤도 슬래브를 타설함으로써 궤도와 교량 상부구조의 상대 변위에 의해 발생하는 전단력을 전달하도록 설계하고 있다. 이 연구에서는 전단키의 전단 거동을 예측하기 위해 타설 경계면을 고려한 비선형 구조 해석 방법을 제시하였다. 제시된 해석 방법은 콘크리트 면에서의 마찰력과 철근의 다월 거동을 고려함으로써 전단키 타설 경계면(시공이음부)에서의 전단력-전단 미끌림 거동을 예측할 수 있으며, 해석 결과 4개의 시험체에 대한 실험 결과를 잘 예측하는 것으로 나타났다.

조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향 (Influence of Tightening Torque on Implant-Abutment Screw Joint Stability)

  • 신현모;정창모;전영찬;윤미정;윤지훈
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.396-408
    • /
    • 2008
  • 연구목적: 임플랜트 치료에서 가장 흔히 발생하는 기계적 문제점 중 하나는 나사의 풀림이다. 지대주 나사에 조임회전력을 가하는 목적은 나사를 신장시켜, 신장된 나사의 인장력에 의한 지대주와 고정체간의 압축력을 통해 연결부의 안정성을 부여하는 데 있다. 조임 회전력의 결과로 나타나는 전하중의 크기는 다양한 요소에 의해 영향을 받기 때문에, 동일한 조임회전력을 적용하였다 할지라도 임플랜트 시스템의 종류에 따라 전하중의 크기가 달라질 수 있다. 따라서 지대주 나사 연결부의 안정성을 위한 다양한 임플랜트 시스템의 적정 조임회전력 크기에 관한 연구가 필요하다. 본 연구에서는 external butt joint와 두 가지 internal cone 연결형태를 갖는 임플랜트 시스템들에서 지대주 나사의 조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향을 하중 전후의 풀림회전력 측정을 통해 알아보고자 하였다. 연구재료 및 방법: External butt joint 형태를 가지는 US II 시스템과 $8^{\circ}$ internal cone 연결형태의 SS II 및 $11^{\circ}$ internal cone 연결형태의 GS II 시스템에서 20 Ncm, 30 Ncm, 그리고 40 Ncm의 각기 다른 조임회전력을 적용한 후 초기 풀림회전력 및 상실률과 $10^5$회의 반복하중 후의 풀림회전력 및 상실률을 비교 분석하였다. 연구결과 및 결론: 1. 초기 풀림회전력과 하중 후 풀림회전력은 조임회전력의 크기가 증가할수록 크게 나타났다 (P < .05). 2. 초기 풀림회전력 상실률은 SS II 시스템에서는 조임회전력 크기에 따른 차이가 없었으나 (P > .05), GS II와 US II에서는 20 Ncm 보다 40Ncm의 조임회전력에서 더 낮게 나타났다 (P < .05). 3. 하중 후 풀림회전력 상실률은 세 시스템 모두 30 Ncm의 조임회전력을 가했을 때 가장 낮게 나타났다 (P < .05). 4. 하중 후 풀림회전력 상실률은 SS II, GS II, 그리고 US II 순으로 높아지는 경향을 보였다. 5. 초기 풀림회전력과 하중 후 풀림회전력 상실률 간에는 상관관계가 없었다 (P > .05). 이상의 결과로부터 임플랜트 시스템의 종류뿐만 아니라 조임회전력의 크기 또한 지대주 나사의 풀림회전력 상실에 영향을 준다는 것을 알 수 있다. 따라서 임플랜트-지대주 나사 연결부 안정성 유지를 위해서는 임플랜트 시스템마다 적정 조임회전력이 제시되어야 하고, 또한 임상에서 이를 준수하는 것이 매우 중요하다고 생각된다.

임상실습 경험 간호학생의 환자 개인정보보호 인식과 실천에 대한 융합적 연구 (Convergence Study on Perception and Performance of Patient Private Information Protection in Nursing Students with Clinical Practice)

  • 이현정
    • 문화기술의 융합
    • /
    • 제4권2호
    • /
    • pp.53-60
    • /
    • 2018
  • 본 연구는 18주간 임상실습을 경험한 간호학생들의 환자 개인정보보호 인식과 실천 정도를 확인하여 정보보호에 대한 관심을 불러일으키고 간호학생들을 위한 환자 개인정보보호 교육 프로그램 마련에 필요한 기반 자료를 제공하고자 시도되었다. 간호학과 4학년 학생 76명을 대상으로 조사한 결과, 환자 개인정보보호 인식 정도(4.62점/5점)가 실천 정도(3.84점/5점)에 비해 통계적으로 유의하게 높았다. 인식 정도와 실천 정도는 통계적으로 유의한 순상관관계가 있었다. 향후 일부 간호학생으로 제한되었던 대상자를 확대하여 간호학생의 환자 개인정보보호 인식과 실천에 영향을 주는 요인을 파악하기 위한 다학제간 융합연구가 필요하고, 간호학생들을 위한 환자 개인정보보호 교육 프로그램 개발과 적용이 필요하며. 환자 개인정보보호 인식과 실천을 향상시키기 위한 의료기관과 대학 측의 공동 방안 모색이 필요하다.

이동통신 환경에서 바이트 정렬 가변 길이 터보 코드의 적응 부호화율 적용을 통한 동영상 전송 시스템 (Robust Video Transmission System Employing Byte-Aligned Variable-Length Turbo Codes and Its Code-Rate Adaptation over Mobile Communication Channels)

  • 이창우;김종원
    • 한국통신학회논문지
    • /
    • 제29권7C호
    • /
    • pp.921-930
    • /
    • 2004
  • 본 논문에서는 회선교환 방식의 이동통신 환경에서 전송 오류에 강인한 동영상 전송 시스템을 구현하기 위해서 채널의 상태에 따라 적응적으로 부호화율을 변화시키는 터보 코드 기반 오류정정 기법을 제안한다. 제안 시스템에서는 먼저 가변길이의 응용계층 단위(segment)로 생성되는 영상 부호화 스트림에 부합하도록 바이트정렬 가변길이 (byte-aligned variable-length) 터보 코드를 사용한다. 즉 ITU-T H.263+ 동영상 스트림을 GOB (group of block) 별로 나누고 이를 채널 상태에 따라 적절한 바이트정렬 가변길이 터보 코드를 적용하여 보호하는 것이다. 이를 위하여 제안된 동영상 전송 시스템의 압축 부호화율과 오류정정 부호화율 간의 상관관계를 분석하고 정적인 상황에서 최적의 부호화율을 먼저 모색한다. 또한 실제적인 이동통신 채널을 적절하게 근사하는 시변 레일리 페이딩(Rayleigh fading) 채널을 모델링한 다음 채널 변화에 따라 부호화율을 적응적으로 조절하는 기법을 제안한다. 마지막으로 제안된 적응 기법의 적용에 따른 성능 향상을 동영상 전송 성능의 비교를 통하여 검증한다.

Piezoelectric impedance based damage detection in truss bridges based on time frequency ARMA model

  • Fan, Xingyu;Li, Jun;Hao, Hong
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.501-523
    • /
    • 2016
  • Electromechanical impedance (EMI) based structural health monitoring is performed by measuring the variation in the impedance due to the structural local damage. The impedance signals are acquired from the piezoelectric patches that are bonded on the structural surface. The impedance variation, which is directly related to the mechanical properties of the structure, indicates the presence of local structural damage. Two traditional EMI-based damage detection methods are based on calculating the difference between the measured impedance signals in the frequency domain from the baseline and the current structures. In this paper, a new structural damage detection approach by analyzing the time domain impedance responses is proposed. The measured time domain responses from the piezoelectric transducers will be used for analysis. With the use of the Time Frequency Autoregressive Moving Average (TFARMA) model, a damage index based on Singular Value Decomposition (SVD) is defined to identify the existence of the structural local damage. Experimental studies on a space steel truss bridge model in the laboratory are conducted to verify the proposed approach. Four piezoelectric transducers are attached at different locations and excited by a sweep-frequency signal. The impedance responses at different locations are analyzed with TFARMA model to investigate the effectiveness and performance of the proposed approach. The results demonstrate that the proposed approach is very sensitive and robust in detecting the bolt damage in the gusset plates of steel truss bridges.

정보보호 관점에서의 오픈뱅킹 수용도에 대한 영향요인 (Factors to Affect Acceptance of Open Banking from Information Security Perspectives)

  • 고정현;이원부
    • 한국IT서비스학회지
    • /
    • 제20권6호
    • /
    • pp.63-81
    • /
    • 2021
  • Joint financial network of Korea Financial Telecommunications and Clearings Institute, which is an essential facility with a natural monopoly, maintained its closedness as monopoly/public utility model, but it has evolved in the form of open banking in order to obtain domestic fintech competitiveness in the rapidly changing digital financial ecosystem such as the acceleration of Big Blur. In accordance with digital transformation strategy of financial institutions, various ICT companies are actively participating in the financial industries, which has been exclusive to banks, through the link technology called Open API. For this reason, there has been a significant change in the financial service supply chain in which ICT companies participate as users. The level of security in the financial service supply chain is determined based on the weakest part of the individual components according to the law of minimum. In addition, there is a perceived risk of personal information and financial information leakage among the main factors that affect users' intention to accept services, and appropriate protective measures against perceived security risks can be a catalyst, which increases the acceptance of open banking. Therefore, this is a study on factors affecting the introduction of open banking to achieve financial innovation by developing an open banking security control model for financial institutions, as a protective measures to user organizations, from the perspectives of cyber financial security and customer information protection, respectively, and surveying financial security experts. It is expected, from this study, that effective information protection measures will be derived to protect the rights and interests of financial customers and will help promote open banking.

임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구 (Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis)

  • 엄태관;서승우;전계록;신정욱;정창모
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.125-135
    • /
    • 2009
  • 연구목적: 임플란트 치료에서 흔히 발생하는 기계적인 문제점을 하나가 지대주나사의 풀림과 파절이다. 일반적으로 나사 연결의 안정성을 위해서는 지대주나사의 조임회전력에 의한 전하중을 나사의 탄성한계까지 증가시킬 필요가 있다. 그러나 저작운동에 의한 기능부하는 전하중이 가해진 지대주나사에 추가적인 인장력을 가하게 되어 나사의 풀림이나 파절의 가능성을 높인다. 이러한 풀림이나 파절을 방지하면서 동시에 최대의 결합 강도를 가지는 조임회전력을 찾는 연구가 필요하다. 본 연구는 지대주나사의 조임회전력이 임플란트-지대주 연결부 안정성에 미치는 영향을 3차원 유한요소 분석을 통하여 확인하고자했다. 연구 재료 및 방법: External butt joint를 가진 임플란트를 기반으로 3차원 유한요소 해석모형을 설계하였다. 조임회전력에 따른 지대주나사의 전하중을 이론치, 실험치 및 해석치를 비교하여 해석모형을 검증하였다. 검증한 해석모형에서 대해 조임회전력을 10 Ncm, 20 Ncm, 30 Ncm, 그리고 40 Ncm로 각각 적용하고 지대주에 30도 경사지게 250 N의 외부하중을 가하여 유산요소 해석을 실시하였다. 그 결과를 통해 지대주나사의 최대 등가응력을 계산하고 고정체와 지대주 연결부의 응력분포 및 이개거리(gap distance)를 산출하였다. 결과 및 결론: 본 연구조건 하에서 다음과 같은 결과를 얻었다. 1. 전하중은 조임회전력이 클수록 증가하였다. 2. 조임회전력 적용 후 최대 등가응력은 지대주나사 경부에서 발생하였으며, 나사산 체결부에서는 주로 경부쪽 네 개의 나사산에 응력이 집중되었다. 3. 외부하중을 가했을 때에도 조임회전력을 적용했을 때와 동일하게 최대 등가응력은 주로 지대주나사 경부에서 발생하였으나, 10 Ncm의 조임회전력을 적용한 경우에서는 지대주나사 두부밑면에서 발생하였다. 4. 외부하중을 가했을 때 10 Ncm와 20 Ncm의 조임회전력을 적용한 경우에서는 연결부 이개(joint opening) 현상이 관찰 되었다. 5. 조임회전력이 40 Ncm인 경우에는 경사하중에 의해 지대주나사의 경부에 발생하는 최대등가응력이 나사의 소재인 티타늄 합금의 허용응력을 초과하였다. 이상의 결과로 볼 때, 조임회전력은 고정체와 지대주 연결부의 안정성에 영향을 미치는 것이 확인되었다. 임플란트 지대주나사는 임상에서 발생하는 기능 하중을 고려하여 고정체와 지대주 연결의 안정성을 유지할 수 있는 적정 조임회전력의 크기가 제안되어야 한다.

임상가를 위한 특집 3 - Endocrown을 이용한 근관치료 후 수복 (Restoration after endodontic treatment with Endocrown)

  • 박정길
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.384-393
    • /
    • 2012
  • Successful treatment of a badly broken down tooth with pulpal disease depends not only on good endodontic therapy, but also on good prosthetic reconstruction of the tooth after endodontic therapy is completed. The ideal treatment of endodontically treated teeth has been widely and controversially discussed. Endocrown is a restorative option for endodontically treated teeth. Endocrown design incorporates the core and short post into the crown as a single restoration. The preparation of endocrown consists of a circular equigingival butt-joint margin and central retention cavity of the entire pulp chamber instead of employing intraradicular posts. This design significantly increases the surface area of the preparation available for cementation. It is particularly useful in young patient teeth for long-term provisional restoration and in teeth with short clinical crowns. This technique represents a promising and conservative method for the treatment of endodontically treated teeth that require long-term protection and stability. Endocrown can be considered as a feasible alternative to full crowns or composite overlays for the restoration of non vital teeth.

중국 성곽유적의 보존 및 관리 (A Study on the City Wall Ruins Preservation and Management of China)

  • 강태호;리아오페이
    • 건축역사연구
    • /
    • 제26권5호
    • /
    • pp.27-38
    • /
    • 2017
  • The main objective of this study is to analyze the preservation and management for the city wall ruins of China, and to find out the implications. Firstly, Chinese walls have experienced a process from demolition to protection. The walls of the historical value of the site are gradually being certified, and many walls ruins were designated as a conservation unit. Secondly, China's institutional system is based on the central government issued Cultural Relics P rotection Law and combined with the actual situation of local governments to establish a special law. Management System is Cultural Relics Bureau, the planning department, the garden department and the tourism sector joint implementation. Thirdly, through the study of Nanjing, Xian, Pingyao, Suzhou city wall ruins finding that perfect legislation and unified management system to help protect city wall ruins.