• Title/Summary/Keyword: joint protection

Search Result 172, Processing Time 0.022 seconds

A Study on Energy Characteristics in Transient States of OF Cable Systems (OF 케이블 계통에서 과도상태시 에너지 특성 검토)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Lee, Dong-Il;Seo, Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

Reliability-aware service chaining mapping in NFV-enabled networks

  • Liu, Yicen;Lu, Yu;Qiao, Wenxin;Chen, Xingkai
    • ETRI Journal
    • /
    • v.41 no.2
    • /
    • pp.207-223
    • /
    • 2019
  • Network function virtualization can significantly improve the flexibility and effectiveness of network appliances via a mapping process called service function chaining. However, the failure of any single virtualized network function causes the breakdown of the entire chain, which results in resource wastage, delays, and significant data loss. Redundancy can be used to protect network appliances; however, when failures occur, it may significantly degrade network efficiency. In addition, it is difficult to efficiently map the primary and backups to optimize the management cost and service reliability without violating the capacity, delay, and reliability constraints, which is referred to as the reliability-aware service chaining mapping problem. In this paper, a mixed integer linear programming formulation is provided to address this problem along with a novel online algorithm that adopts the joint protection redundancy model and novel backup selection scheme. The results show that the proposed algorithm can significantly improve the request acceptance ratio and reduce the consumption of physical resources compared to existing backup algorithms.

Ultrasound Guided Nerve Block at Vertebra and Lower Extremity (초음파를 활용한 하지와 체간부위의 신경차단술)

  • Park, Hyeng-Kyu
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.93-98
    • /
    • 2021
  • The use of ultrasonography has recently been increasing in musculoskeletal diagnosis or intervention treatment. Ultrasound guided procedure offers a reliable alternative to fluoroscopy or computed tomography for lumbar medial branch block, facet joint block and peripheral nerves of lower extremity. Further, there is no exposure to radiation and additional equipment necessary for the protection against radiation is required. And ultrasound guided procedure needs smaller space than fluoroscopy guided procedure with real time images in the outpatient department. This article reviews ultrasound guided procedure at lumbar vertebra and peripheral nerves of lower extremity.

Dynamic Fog-Cloud Task Allocation Strategy for Smart City Applications

  • Salim, Mikail Mohammed;Kang, Jungho;Park, Jong Hyuk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.128-130
    • /
    • 2021
  • Smart cities collect data from thousands of IoT-based sensor devices for intelligent application-based services. Centralized cloud servers support application tasks with higher computation resources but introduce network latency. Fog layer-based data centers bring data processing at the edge, but fewer available computation resources and poor task allocation strategy prevent real-time data analysis. In this paper, tasks generated from devices are distributed as high resource and low resource intensity tasks. The novelty of this research lies in deploying a virtual node assigned to each cluster of IoT sensor machines serving a joint application. The node allocates tasks based on the task intensity to either cloud-computing or fog computing resources. The proposed Task Allocation Strategy provides seamless allocation of jobs based on process requirements.

Development of a Specialized Underwater Leg Convertible to a Manipulator for the Seabed Walking Robot CR200 (해저 보행 로봇 CR200을 위한 매니퓰레이터 기능을 갖는 다리 개발)

  • Kang, Hangoo;Shim, Hyungwon;Jun, Bong-Huan;Lee, Pan-Mook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.8
    • /
    • pp.709-717
    • /
    • 2013
  • This paper presents the development of a specialized underwater leg with a manipulator function(convertible-to-arm leg) for the seabed walking robot named CRABSTER200(CR200). The objective functions of the convertible-to-arm leg are to walk on the seabed and to work in underwater for precise seabed exploration and underwater tasks under coastal area with strong tidal current. In order to develop the leg, important design elements including the degree of freedom, dimensions, mass, motion range, joint structure/torque/angular-speed, pressure-resistance, watertight capability and cable protection are considered. The key elements of the convertible-to-arm leg are realized through concept/specific/mechanical design and implementation process with a suitable joint actuator/gear/controller selection procedure. In order to verify the performance of the manufactured convertible-to-arm leg, a 25bar pressure-resistant and watertight test using a high-pressure chamber and a joints operating test with posture control of the CR200 are performed. This paper describes the whole design, realization and verification process for implementation of the underwater convertible-to-arm leg.

Segmental Hard Shell Design of Knee Protector for Children Using 3D Printing (3차원 프린팅을 이용한 어린이용 무릎보호대의 분절형 하드쉘 설계)

  • Lee, Hyojeong;Lee, Yejin
    • Journal of Fashion Business
    • /
    • v.21 no.4
    • /
    • pp.116-126
    • /
    • 2017
  • This study applied a segmented hard shell design on knee protectors for children with the objective of increasing mobility. The prototype of the hard shell that does not correspond to movement of the body among components of the knee protector was developed. Surface modeling was conducted based on 3D knee data to enhance comfort through optimized fit on the knee joint where the hard shell would be worn. For this, previous studies on changes in skin near the knee joint during knee flexion were reviewed to establish basic segmental lines. The basic design included six segments, and the number of segments was used as the design variable by increasing or decreasing it to 0, 3, 6, 9, and 14 segments. A prototype was produced from 3D printing with TPU material, worn for wearing assessment. Results revealed fewer numbers of segments resulting in less fit with the body, while actual appearance was stable. Meanwhile, the number of proper segments improved better fit with the body during movement. The wearing assessment revealed the amount of gap reflects change in skin length depending on movement. Assessment results demonstrated basic segment design, S6 with 6 segments, had the best design and most optimized fit. Findings in this study can provide key data for designing knee protection products for children.

Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings

  • Vahedian, Abbas;Mahini, Seyed Saeed;Glencross-Grant, Rex
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.3
    • /
    • pp.269-282
    • /
    • 2015
  • Civil structures should be designed with the lowest cost and longest lifetime possible and without service failure. The efficient and sustainable use of materials in building design and construction has always been at the forefront for civil engineers and environmentalists. Timber is one of the best contenders for these purposes particularly in terms of aesthetics; fire protection; strength-to-weight ratio; acoustic properties and seismic resistance. In recent years, timber has been used in commercial and taller buildings due to these significant advantages. It should be noted that, since the launch of the modern building standards and codes, a number of different structural systems have been developed to stabilise steel or concrete multistorey buildings, however, structural analysis of high-rise and multi-storey timber frame buildings subjected to lateral loads has not yet been fully understood. Additionally, timber degradation can occur as a result of biological decay of the elements and overloading that can result in structural damage. In such structures, the deficient members and joints require strengthening in order to satisfy new code requirements; determine acceptable level of safety; and avoid brittle failure following earthquake actions. This paper investigates performance assessment and damage assessment of older multi-storey timber buildings. One approach is to retrofit the beams in order to increase the ductility of the frame. Experimental studies indicate that Sprayed Fibre Reinforced Polymer (SFRP) repairing/retrofitting not only updates the integrity of the joint, but also increases its strength; stiffness; and ductility in such a way that the joint remains elastic. Non-linear finite element analysis ('pushover') is carried out to study the behaviour of the structure subjected to simulated gravity and lateral loads. A new global index is re-assessed for damage assessment of the plain and SFRP-retrofitted frames using capacity curves obtained from pushover analysis. This study shows that the proposed method is suitable for structural damage assessment of aged timber buildings. Also SFRP retrofitting can potentially improve the performance and load carrying capacity of the structure.

Matrix metalloproteinase-13 downregulation and potential cartilage protective action of the Korean Red Ginseng preparation

  • Lee, Je Hyeong;Shehzad, Omer;Ko, Sung Kwon;Kim, Yeong Shik;Kim, Hyun Pyo
    • Journal of Ginseng Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2015
  • Background: The present study was designed to prepare and find the optimum active preparation or fraction from Korea Red Ginseng inhibiting matrix metalloproteinase-13 (MMP-13) expression, because MMP-13 is a pivotal enzyme to degrade the collagen matrix of the joint cartilage. Methods: From total red ginseng ethanol extract, n-BuOH fraction (total ginsenoside-enriched fraction), ginsenoside diol-type-enriched fraction (GDF), and ginsenoside triol-type-enriched fraction (GTF) were prepared, and ginsenoside diol type-/F4-enriched fraction (GDF/F4) was obtained from Panax ginseng leaf extract. Results: The n-BuOH fraction, GDF, and GDF/F4 clearly inhibited MMP-13 expression compared to interleukin-$1{\beta}$-treated SW1353 cells (human chondrosarcoma), whereas the total extract and ginsenoside diol-type-enriched fraction did not. In particular, GDF/F4, the most effective inhibitor, blocked the activation of p38 mitogen-activated protein kinase (p38 MAPK), c-Jun-activated protein kinase (JNK), and signal transducer and activator of transcription-1/2 (STAT-1/2) among the signal transcription pathways involved. Further, GDF/F4 also inhibited the glycosaminoglycan release from interleukin-$1{\alpha}$-treated rabbit cartilage culture (30.6% inhibition at $30{\mu}g/mL$). Conclusion: Some preparations from Korean Red Ginseng and ginseng leaves, particularly GDF/F4, may possess the protective activity against cartilage degradation in joint disorders, and may have potential as new therapeutic agents.

Calculation of Dose Conversion Coefficients in the Anthropomorphic MIRD Phantom in Broad Unidirectional Beams of Monoenergetic Photons (MIRD 인형팬텀의 넓고 평행한 감마선빔에 대한 선량 환산계수 계산)

  • Chang, Jai-Kwon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.47-58
    • /
    • 1997
  • The conversion coefficients of effective dose per unit air kerma and equivalent dose per unit fluence were calculated by MCNP4A code for antero-posterior(AP) and postero- anterior(PA) incidence of broad, unidirectional beams of photons into anthropomorphic MIRD phantom. Calculations have been performed for 20 monoenergetic photons of energy ranging from 0.03 to 10 MeV. The conversion coefficients showed a good agreement with the corresponding values given in the draft publication of joint task group of ICRP and ICRU within 10%. The deviations may arise from the differences of geometry in the MIRD phantom and the ADAM/EVE phantoms, and the differences in the codes and cross-section data used. Inclusion of a specific oesophagus model results in effective dose slightly different(5% at most) from the effective doses obtained by adopting the equivalent doses for the thymus or pancreas. Deletion of the ULI from the remainder organ appeared not to be significant for the cases of photon dosimetry covered in this study.

  • PDF

Influence of Calm Conditions on the Atmospheric Dispersion of Radioactive Effluents at KAERI Site (한국원자력연구소 부지에서 방사성물질의 대기확산에 대한 정온상태의 영향)

  • Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Choi, Young-Gil;Han, Moon-Hee;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.103-107
    • /
    • 1998
  • The influence of calm conditions on the atmospheric dispersion analyses at KAERI site, which is located at a complex inland basin, was investigated. The U. S. NRC's computer programs XOQDOQ and PAVAN were used to estimate dispersion factors for routine and postulated accidental releases from nuclear facilities, respectively. The joint frequency distribution was obtained from the annual meteorological data measured in 1997 and used as input data of the computer programs. When the definition of calm is changed from 0.5 m $sec^{-1}$ to 0.21 m $sec^{-1}$, the maximum sector dispersion factor becomes 1.62 and 2.16 times higher for routine and postulated accidental releases, respectively.

  • PDF