• 제목/요약/키워드: joint loss

검색결과 474건 처리시간 0.021초

Dynamics of the Macpherson Strut Motor-Vehicle Suspension System in Point and Joint Coordinates

  • Attia, Hazem-Ali
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1287-1296
    • /
    • 2003
  • In this paper the dynamic analysis of the Macpherson strut motor-vehicle suspension system is presented. The equations of motion are formulated using a two-step transformation. Initially, the equations of motion are derived for a dynamically equivalent constrained system of particles that replaces the rigid bodies by applying Newton's second law The equations of motion are then transformed to a reduced set in terms of the relative joint variables. Use of both Cartesian and joint variables produces an efficient set of equations without loss of generality For open chains, this process automatically eliminates all of the non-working constraint forces and leads to an efficient solution and integration of the equations of motion. For closed loops, suitable joints should be cut and few cut-joints constraint equations should be included for each closed chain. The chosen suspension includes open and closed loops with quarter-car model. The results of the simulation indicate the simplicity and generality of the dynamic formulation.

등속조인트 외륜 열간단조의 금형수명 향상을 위한 단조공정 유한요소해석 (FE Analysis of Forging Process for Improving Tool Life in Hot Forging of CV Joint Outer Race)

  • 김용조
    • 한국기계가공학회지
    • /
    • 제13권3호
    • /
    • pp.56-62
    • /
    • 2014
  • During the hot forging process, the most common cause of tool failure is wear. Tool wear results in the gradual loss of part tolerances, after which eventually the tool must be replaced or repaired. In order to maximize the lifetimes of forging tools, it is important to investigate the wear mechanisms of these tools. In this study, the hot forging of the outer race of an automotive constant-velocity joint was analyzed by a finite element method to investigate the wear distribution, especially the amount and location of the maximum expected wear damage, using Archard's wear model, which was modified considering the forging temperature. Forging analyses were carried out after modifying blocker forging tools based on established versions. The modified blocker tools resulted in an increase in the tool life up to 31% with a finisher punch.

Adaptive Techniques for Joint Optimization of XTC and DFE Loop Gain in High-Speed I/O

  • Oh, Taehyoun;Harjani, Ramesh
    • ETRI Journal
    • /
    • 제37권5호
    • /
    • pp.906-916
    • /
    • 2015
  • High-speed I/O channels require adaptive techniques to optimize the settings for filter tap weights at decision feedback equalization (DFE) read channels to compensate for channel inter-symbol interference (ISI) and crosstalk from multiple adjacent channels. Both ISI and crosstalk tend to vary with channel length, process, and temperature variations. Individually optimizing parameters such as those just mentioned leads to suboptimal solutions. We propose a joint optimization technique for crosstalk cancellation (XTC) at DFE to compensate for both ISI and XTC in high-speed I/O channels. The technique is used to compensate for between 15.7 dB and 19.7 dB of channel loss combined with a variety of crosstalk strengths from $60mV_{p-p}$ to $180mV_{p-p}$ adaptively, where the transmit non-return-to-zero signal amplitude is a constant $500mV_{p-p}$.

Multiple Ossicular Dislocation Including Stapediovestibular Dislocation Presenting with Conductive Hearing Loss

  • Lee, Geonho;Kim, Yoonjoong;Kim, Bong Jik
    • Journal of Audiology & Otology
    • /
    • 제25권3호
    • /
    • pp.159-162
    • /
    • 2021
  • Temporal bone trauma can cause hearing loss and in case of prolonged conductive hearing loss, traumatic ossicular injury should be considered. Separation of the incudostapedial joint is the most common lesion, and stapediovestibular dislocation is relatively rare but can easily cause perilymphatic fistula. Here, we report a very rare case of external stapediovestibular dislocation after trauma, ending up with successful surgical outcome. A 27-year-old man with non-progressive hearing loss on the right side since childhood visited the clinic. Audiogram showed a conductive hearing loss with air-bone gap of 55 dB on the right side. Temporal bone CT revealed the disruption of ossicular chain. An exploratory tympanotomy identified multiple ossicular disruptions including external stapediovestibular dislocation with shiny fibrous membrane sealing the oval window. Ossicular chain reconstruction was performed using the total ossicular replacement prosthesis of titanium. A postoperative audiogram showed a recovery of air-bone gap less than 10 dB. To the best of our knowledge, this is the first case of external long-standing stapediovestibular dislocation, with oval window completely sealed with fibrous membrane, ending up with successful hearing recovery by surgery. This case would help dealing with such condition which can be encountered in the clinic.

Multiple Ossicular Dislocation Including Stapediovestibular Dislocation Presenting with Conductive Hearing Loss

  • Lee, Geonho;Kim, Yoonjoong;Kim, Bong Jik
    • 대한청각학회지
    • /
    • 제25권3호
    • /
    • pp.159-162
    • /
    • 2021
  • Temporal bone trauma can cause hearing loss and in case of prolonged conductive hearing loss, traumatic ossicular injury should be considered. Separation of the incudostapedial joint is the most common lesion, and stapediovestibular dislocation is relatively rare but can easily cause perilymphatic fistula. Here, we report a very rare case of external stapediovestibular dislocation after trauma, ending up with successful surgical outcome. A 27-year-old man with non-progressive hearing loss on the right side since childhood visited the clinic. Audiogram showed a conductive hearing loss with air-bone gap of 55 dB on the right side. Temporal bone CT revealed the disruption of ossicular chain. An exploratory tympanotomy identified multiple ossicular disruptions including external stapediovestibular dislocation with shiny fibrous membrane sealing the oval window. Ossicular chain reconstruction was performed using the total ossicular replacement prosthesis of titanium. A postoperative audiogram showed a recovery of air-bone gap less than 10 dB. To the best of our knowledge, this is the first case of external long-standing stapediovestibular dislocation, with oval window completely sealed with fibrous membrane, ending up with successful hearing recovery by surgery. This case would help dealing with such condition which can be encountered in the clinic.

An anti-noise real-time cross-correlation method for bolted joint monitoring using piezoceramic transducers

  • Ruan, Jiabiao;Zhang, Zhimin;Wang, Tao;Li, Yourong;Song, Gangbing
    • Smart Structures and Systems
    • /
    • 제16권2호
    • /
    • pp.281-294
    • /
    • 2015
  • Bolted joint connection is the most commonly used connection element in structures and devices. The loosening due to external dynamic loads cannot be observed and measured easily and may cause catastrophic loss especially in an extreme requirement and/or environment. In this paper, an innovative Real-time Cross-Correlation Method (RCCM) for monitoring of the bolted joint loosening was proposed. We apply time reversal process on stress wave propagation to obtain correlation signal. The correlation signal's peak amplitude represents the cross-correlation between the loosening state and the baseline working state; therefore, it can detect the state of loosening. Since the bolt states are uncorrelated with noise, the peak amplitude will not be affected by noise and disturbance while it increases SNR level and increases the measured signals' reliability. The correlation process is carried out online through physical wave propagation without any other post offline complicated analyses and calculations. We implemented the proposed RCCM on a single bolt/nut joint experimental device to quantitatively detect the loosening states successfully. After that we implemented the proposed method on a real large structure (reaction wall) with multiple bolted joint connections. Loosening indexes were built for both experiments to indicate the loosening states. Finally, we demonstrated the proposed method's great anti-noise and/or disturbance ability. In the instrumentation, we simply mounted Lead Zirconium Titanate (PZT) patches on the device/structure surface without any modifications of the bolted connection. The low-cost PZTs used as actuators and sensors for active sensing are easily extended to a sensing network for large scale bolted joint network monitoring.

요통환자의 천장관절에 대한 도수교정 전과 후의 골반경사 비교 (A Comparison of Pelvic Tilt Before and After Manipulation of Sacroiliac Joint in the Patients with Low Back Pain)

  • 오승길;이진행
    • 대한물리치료과학회지
    • /
    • 제7권2호
    • /
    • pp.579-595
    • /
    • 2000
  • The purposes of this study were to compare pelvic tilt before and after manipulation of sacroiliac joint in 31 low back pain patients (11 males, 20 females) with sacroiliac joint dysfunction. The sacroiliac joint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard (1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac joint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of pelvic tilt angle before and after manipulation, and Pearson product-moment correlation analysis was performed for intratester reliability for measurements of pelvic tilt angle before and after manipulation. The result were as follows: 1. Intratester reliability was good for measures of pelvic tilt (r=.98). 2. The pelvic tilt after manipulation was significantly decreased (mean=$3.40^{\circ}$) compared with the pelvic tilt before manipulation (p=.001). All subjects showed asymmetrical right versus left pelvic tilt before manipulation. 40% of subjects showed decreased asymmetrical right versus left pelvic tilt after manipulation, and 60% of subjects showed symmetrical right versus left pelvic tilt after manipulation. I think that pelvic tilt asymmetry with hypomobility due to loss of joint play could be symmetrized by manipulation or mobilization, but pelvic tilt asymmetry with unilateral pelvic muscle shortening could not be symmetrized by manipulation or mobilization without relaxation and stretching of shortened muscles.

  • PDF

신연 외고정 및 지속적 반수동 운동을 이용한 경골 원위부 필론 골절의 치료 (Continuous Half Passive Motion under Distracted External Fixation for the Treatment of Distal Tibial Pilon Fractures)

  • 배서영;정형진;신용운;박재구
    • 대한족부족관절학회지
    • /
    • 제14권2호
    • /
    • pp.146-150
    • /
    • 2010
  • Purpose: Pilon fracture has several serious complications such as joint stiffness, arthrosis and delayed angular deformity. We report short-term results of new treatment modality using distracted dynamic external fixators and early controlled ankle motion. Materials and Methods: Eight cases of severe pilon fractures for which we tried small plate fixation and additional distracted dynamic external fixators from July 2007 to June 2009 were included. Half passive continuous ankle joint motion was allowed under free hinged ring fixators after the operation. The external fixators were removed after two or three months from the surgery. We investigated joint space by radiograph, joint pain, range of motion, patient's satisfaction of treatment protocol. Results: Joints were distracted when external fixators were applied and mean 28% of space loss developed after removal of external fixators. In most of cases, satisfactory alignments were maintained. Regarding range of joint motion, mean dorsiflexion angle was 15 degrees and mean plantarflexion angle was 32 degree in the condition of wearing external fixators. There was mean 8% reduction of range of motion but no further progression of ankle stiffness after removal of external fixators. Dorsiflexion was not improved after that, but plantarflexion angle was improved 10% even after removal of external fixators. Patients were generally in compliance with the treatment protocols with high level of satisfaction. Conclusion: We got good results with distracted dynamic external fixators and early continuous half-passive joint motion for pilon fractures in terms of joint pain and range of motion. Therefore we suggest this new protocol as an alternative modality for severe pilon fractures.

슬관절내에 발생한 눈사람 형태의 결절성 건활액막염 - 증례보고 - (Snow-Man Shaped Nodular Tenosynovitis in the Knee - Case Report -)

  • 이건우;이근수;송상호;김명구;윤상현
    • 대한관절경학회지
    • /
    • 제3권1호
    • /
    • pp.44-47
    • /
    • 1999
  • 저자들은 25세 남자로서 특별한 외상없이 좌측 슬관절 내에 발생한 결절성 건활액막염으로 확진된 1례를 보고하는 바이다. 환자는 좌측 슬관절 슬와부에 경미한 정도의 압통이 있었으며, $100^{\circ}$에서 굴곡장애가 특별한 외상 없이 내원 5개월 전 부터 발생하였다. 관절경적 진단 및 종물 제거 후 증상의 소실과 굴곡장애가 없어졌으며, 1년간의 추시 관찰시 증상의 재현은 없었다.

  • PDF

Ni계 합금으로 브레이징된 Fe-Cr-Al 합금 접합부의 주기산화거동 (Cyclic Oxidation Behavior of Fe-Cr-Al Joint Brazed with Nickel-Base Filler Metal)

  • 문병기;최철진;박원욱
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.141-149
    • /
    • 1999
  • Brazing of Fe-Cr-Al alloy was carried out at $1200^{\circ}C$ in vacuum furnace using nickel-based filler metals : BNi-5 powder(Ni-Cr-Si-Fe base alloy} and MBF-50 foil (Ni-Cr-Si-B). The effect of boron content on the stability of oxide scale on the brazed joint was investigated by means of cyclic oxidation test performed at $1050^{\circ}C$ and $1200^{\circ}C$. Apparently, the joints brazed with MBF-50 containing boron showed relatively stable oxidation rates compared to boron-free BNi-5 at both temperatures. However, it was considered that the slower weight loss of MBF-50 brazed specimen wasn’t resulted from the low oxidation rate but from the spallation of oxide layer. The oxide layer consisted of thick spinel oxide on the surface and $Al_2 O_3$ internal oxide layer along the interface between mother alloy and braze, the mother alloy was also eroded seriously by the formation of spinel oxides such as $FeCr_2 O_4$ and $NiCr_2 O_4$ on the surface, likely to be induced by the change of oxide forming mechanism due to diffusion of boron from the braze. On the contrary, the joint brazed with BNi-5 showed the good oxidation resistance during the cyclic oxidation test. It seems that the oxidation can be retarded by the formation of stable $Al_2 O_3$ layer at the surface.

  • PDF