• 제목/요약/키워드: joint loss

검색결과 474건 처리시간 0.028초

Effect of Sodium Chloride on Weight Loss of AA1100 Aluminum Alloy and SGACD Zinc coated Steel Lap Joint

  • Maulidin, Achmad;Kimapong, Kittipong
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.39-45
    • /
    • 2015
  • This research aims to study an effect of sodium chloride solution concentration on the corrosion rate of AA1100 aluminium alloy and SGACD zinc coated steel lap joint with a test duration of 30 days and a test temperature of $45^{\circ}$. The summarized results are as follows. Increase of the NaCl solution concentration increased the weight loss of Al, corrosion rate of Al, weight loss of Fe and also decreased the corrosion rate of Fe. Increase of the test duration affected to increase the weight loss and corrosion rate of Al and also decrease the weight loss and corrosion rate of Fe. The corrosion that was formed in a lap joint consisted of the uniform corrosion on the surface of the metals and the galvanic corrosion in the lap area of the joint. The maximum weight loss of AA 1100 aluminium and SGACD zinc coated steel that was occurred in the sodium chloride with 3.25% was 2.203% and 3.208%, respectively.. The maximum corrosion rate of AA 1100 aluminium and SGACD zinc coated steel that was occurred in 4.00% and 3.5% sodium chloride solution was 0.156 mm/year and 0.479 mm/year, respectively.

Influence of end-joint methods on magnetization loss in striated helical conductors

  • Kim, Woo-Seok;Kim, Yungil;Choi, Kyeongdal;Lee, Ji-Kwang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.39-43
    • /
    • 2013
  • To reduce the magnetization loss of a coated conductor, the striation and the transposition have to be accomplished for magnetic decoupling. The loss reduction effect in incomplete as well as complete striated YBCO CCs was reported in previous research. At the case of the incomplete striated sample, the end region of the sample is non-striated. So, it is not jointed with each other. In power applications, the joint is needed because current leads must be connected with HTS coils. In this research, the influence of end-joint methods with copper and superconducting joint on magnetization loss in striated YBCO CC and spiral winding samples are presented and compared with non-striated measured result.

간극이 있는 링크기구의 동특성 (Dynamic Characteristics of Link Mechanism with Clearance)

  • 최연선;배성준
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.1050-1057
    • /
    • 1999
  • The existence of clearance at the link joint of a machine is inevitable for assembly and mobility. During the cyclic operation of a machine, rapid changes of the direction and magnitude of connection forces cause momentary loss of contact between the pin and the bushing at the link joint. Contact loss at the clearance joint gives rise to undesirable impact. The impulsive force affects on the performance of the machine, and leads to excessive vibration, noise and faster wear in the connecitons. In this paper, experiment and theoretical analysis were carried out for the variation of crank speed and clearance size. The link mechanism employed in this investigation was newly designed to check the effects of parameter changes on the occurrence of contact loss and on the magnitude of the impact force. The contact loss and impact position were calculated with various driving conditions.

  • PDF

삽입손실 개선을 위한 링 접촉식 구조의 L대역 로터리조인트 설계 (Design of the L-band Rotary Joint in Ring Contact Type to Improve Signal Insertion Loss)

  • 나재현;노돈석;김동길
    • 한국전자통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.41-48
    • /
    • 2019
  • 본 논문에서는 추적 레이더시스템의 핵심부품인 L대역 로터리조인트의 설계를 다룬다. 로터리조인트는 추적 시스템 안테나 회전부에 장착되어 회전하는 안테나와 고정된 신호처리부를 연결하는 구성품으로 안테나의 회전시에도 꼬임이 없이 RF신호를 원활하게 전달하는 주요부품이다. 로터리조인트의 신호 삽입손실을 개선하기 위해, 유전체 종류, 급전분배링 형상 및 유전체 형상 등을 다양하게 수정하였다. 제안한 로터로조인트는 해외 도입품과 비교하여 향상된 성능을 확인하였다. 도입품 로터리조인트의 최대 삽입손실은 1.26dB이었으나, 본 논문에서 제안한 로터리조인트의 최대 삽입손실은 0.68dB로 도입품 대비 약 46%정도 개선되는 것을 확인하였다.

A Novel Algorithm of Joint Probability Data Association Based on Loss Function

  • Jiao, Hao;Liu, Yunxue;Yu, Hui;Li, Ke;Long, Feiyuan;Cui, Yingjie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권7호
    • /
    • pp.2339-2355
    • /
    • 2021
  • In this paper, a joint probabilistic data association algorithm based on loss function (LJPDA) is proposed so that the computation load and accuracy of the multi-target tracking algorithm can be guaranteed simultaneously. Firstly, data association is divided in to three cases based on the relationship among validation gates and the number of measurements in the overlapping area for validation gates. Also the contribution coefficient is employed for evaluating the contribution of a measurement to a target, and the loss function, which reflects the cost of the new proposed data association algorithm, is defined. Moreover, the equation set of optimal contribution coefficient is given by minimizing the loss function, and the optimal contribution coefficient can be attained by using the Newton-Raphson method. In this way, the weighted value of each target can be achieved, and the data association among measurements and tracks can be realized. Finally, we compare performances of LJPDA proposed and joint probabilistic data association (JPDA) algorithm via numerical simulations, and much attention is paid on real-time performance and estimation error. Theoretical analysis and experimental results reveal that the LJPDA algorithm proposed exhibits small estimation error and low computation complexity.

전력기기에서 $100 A/mm^2$급 Bi-2223테이프 ($100 A/mm^2$ Class Bi-2223 Tapes in Electromechanical Devices)

  • 류경우;최경주;성기철;류강식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.55-60
    • /
    • 2002
  • $100 A/mm^2$ class Bi-2223 tapes have recently become commercially available. Some important characteristics of the tapes, e .g. critical current, ac loss, characteristics at joint, fault current characteristics, are required for an application such as a power cable or a power transformer. In this paper they have been investigated experimentally. The results indicate that the self-field loss of the high current density tapes is not negligible, compared to resistive loss in a copper wire for the same currents. In a cable, the self-field loss for relatively large currents is much larger than the magnetization loss due to an external field. But in a transformer, the magnetization loss is dominant, compared to the self-field loss. Finally the fault current characteristics show that the high current density tapes are never safe from burn-out even for fault currents with a few cycles.

밀리미터파대역(Ka-대역)소형 레이더용 고 전력 저 손실 2축 도파관 로터리 조인트 연구 (A Study on the High-power Low-loss Dual Axes Waveguide Rotary Joint for Ka-Band Millimeter-Wave Small Radar)

  • 정채현;성종현;백종균;이국주;박창현;권준범
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.91-96
    • /
    • 2018
  • 본 논문에서는 고 전력 저 손실 특성을 가지는 소형 레이더용 Ka-대역 밀리미터파 2축 도파관 로터리 조인트 설계 및 제작하였다. 전기적 성능은 상온 S-parameter 시험, 고 전력 시험, 운용 온도 시험을 통해 검증하였다. 로터리 조인트는 기능적으로 구형 도파관에서 원형 도파관으로 변환하는 모드 변환기 구조 및 회전 부분의 초크 구조로 구성된다. 본 구조는 고정된 송신기와 2축으로 회전하는 안테나를 최소 손실을 가지도록 전기적 연결 및 경량화를 고려하여 설계하였다. 설계된 로터리 조인트는 중심 주파수 Fc 기준 ${\pm}500MHz$의 대역에서 VSWR 1.5:1 이하 반사 손실, -2.0 dB 이상 삽입 손실 특성을 가지며, 측정 결과는 설계 결과와 유사함을 확인하였다.

Comparison of Power Loss and Magnetic Flux Distribution in Octagonal Wound Transformer Core Configurations

  • Cinar, Mehmet Aytac;Alboyaci, Bora;Sengul, Mehlika
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1290-1295
    • /
    • 2014
  • In this paper, various configurations of octagonal wound transformer core topology, which has previously proved advantages on conventional wound cores, are studied. Each configuration has different joint types and different placement of joint zones on the core. Magnetic flux distributions and power losses of each configuration are analyzed and compared. Comparisons are based on both 2D&3D finite element simulations and experimental studies. The results show that, joint types and their placements on the core cause local flux accumulations and dramatically affect power loss of the core.

High Temperature Superconducting tape의 joint 후 AC loss특성 (Characteristics of AC loss after jointing High Temperature Superconducting tape)

  • 김해준;심기덕;조전욱;정희열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.931-932
    • /
    • 2007
  • Specially, High Temperature Superconducting power-transmission cable(HTS cable), 3-phase 100m long, 22.9kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st century frontier project in Korea. This cable was installed in KEPCO(Go-chang) testing site. In case of manufacturing HTS cable, superconducting joint is very important because they need very long tapes. Therefore, this paper gives some investigation of AC Loss in joined HTS tape by using several joint methods. Finally, this paper was shown background data for the form of HTS cable joint.

  • PDF

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.