• Title/Summary/Keyword: joint detection

Search Result 411, Processing Time 0.034 seconds

It is Time to Have Rest: How do Break Types Affect Muscular Activity and Perceived Discomfort During Prolonged Sitting Work

  • Ding, Yi;Cao, Yaqin;Duffy, Vincent G.;Zhang, Xuefeng
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.207-214
    • /
    • 2020
  • Background: Prolonged sitting at work can lead to adverse health outcomes. The health risk of office workers is an increasing concern for the society and industry, with prolonged sitting work becoming more prevalent. Objective: This study aimed to explore the variation in muscle activities during prolonged sitting work and found out when and how to take a break to mitigate the risk of muscle symptoms. Methods: A preliminary survey was conducted to find out the prevalence of muscle discomfort in sedentary work. Firstly, a 2-h sedentary computer work was designed based on the preliminary study to investigate the variation in muscle activities. Twenty-four participants took part in the electromyography (EMG) measurement study. The EMG variations in the trapezius muscle and latissimus dorsi were investigated. Then the intervention time was determined based on the EMG measurement study. Secondly, 48 participants were divided into six groups to compare the effectiveness of every break type (passive break, active break of changing their posture, and stand and stretch their body with 5 or 10 mins). Finally, data consisting of EMG amplitudes and spectra and subjective assessment of discomfort were analyzed. Results: In the EMG experiment, results from the joint analysis of the spectral and amplitude method showed muscle fatigue after about 40 mins of sedentary work. In the intervention experiment, the results showed that standing and stretching for 5 mins was the most effective break type, and this type of break could keep the muscles' state at a recovery level for about 30-45 mins. Conclusions: This study offers the possibility of being applied to office workers and provides preliminary data support and theoretical exploration for a follow-up early muscle fatigue detection system.

Apoptosis Detected by in Situ DNA end-extension in Osteosarcomas - In relation to p53 and Bcl-2 expression -

  • Park, Yong-Koo;Yang, Moon-Ho;Park, Hye-Rim;Kim, Youn-Wha;Lee, Ju-Hie
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.2
    • /
    • pp.69-79
    • /
    • 1997
  • Objective : The objective of this study was to compare expression of various proto-oncogenes and rates of apoptosis in osteosarcoma patients. Modulation of apoptosis may influence resistance to chemotherapy and therefore affect the outcome of cancer treatment. Osteosarcoma is one of the most fatal malignancies in young adolescents and investigation of the role of apoptotic cell death is warranted in relation to chemotherapy and tumor outcome. Design : The terminal deoxynucleotidyl transferase to exposed 3'-hydroxyl termini of DNA (TUNEL method) staining method has been applied for the in situ detection of DNA double strand breaks. Patients : Thirty-three osteosarcomas in various stages of differentiation from twenty-nine patients were investigated immunohistochemically for p53, Bcl-2 and TUNEL method for apoptosis. Results and conclusion; We have found that higher level of wild type p53 were correlated with enhanced expression of apoptosis. Increased apoptosis rates were found in cases of negative Bcl-2 expression. In the present study, we have concluded that a significant proportion of osteosarcoma, a tumor in which resistance to chemotherapy often occurs, express high levels of p53 and low levels of Bcl-2. Our data provide further evidence for cross-talk between Bcl-2 and p53 and suggests that these genes are important determinants of drug-induced apoptosis.

  • PDF

Antioxidant Activity and Standardization of Extraction Solvents of SJ004 (SJ004의 추출용매별 항산화 활성 및 표준화 연구)

  • Lee, Dae-Yeon;Jo, Ju-Hwi;Kim, Wan-Su;Lee, Ho-Sung;Yi, Young-Woo;Park, Sang-In;An, Keon-Sang;Lee, In-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.2
    • /
    • pp.67-75
    • /
    • 2020
  • Objectives SJ004 is a natural herbal medicine that contains Acyranthes japonica Nakai and Eucommia ulmoides Oliver traditionally used for joint and spinal diseases. This study aimed to establish an efficient method of extracting SJ004 to standardize using the yield, high-performance liquid chromatography (HPLC), and antioxidant assay. Methods SJ004 was extracted with distilled water, 70% and 100% of ethyl alcohol (EtOH). The method validation of 20-hydroxyecdysone and pinoresinol diglucoside was determined by HPLC-photo diode array and the content of SJ004 was calculated. The antioxidant activity of each extract was compared and measured using total flavonoids, total phenolic compounds, 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid), and ferric reducing antioxidant power according to the standard protocol. Results The yield was highest in pure water extract and lowest in 100% EtOH. But, the content of marker compounds indicating 20-hydroxyecdysone and pinoresinol diglucoside was highest in 100% EtOH extract. In the physiological activity measurement using antioxidant activity, 100% ethanol extract was highest. The limit of detection indicating 20-hydroxyecdysone and pinoresinol diglucoside were analyzed 0.33 ㎍/mL, 0.1616 ㎍/mL, and the limit of quantification were analyzed 1.01 ㎍/mL and 0.49 ㎍/mL respectively. Conclusions The experimental results showed that the extraction conditions have a significant effect on content of marker compounds and antioxidant activity. As a result of method validation, SJ004 was standardized by 20-hydroxyecdysone and pinoresinol diglucoside.

Development of the Active Ankle Foot Orthosis to Induce the Normal Gait for the Paralysis Patients (마비 환자의 정상적 보행을 위한 능동형 단하지 보조기 개발)

  • Hwang, Sung-Jae;Kim, Jung-Yoon;Hwang, Seon-Hong;Park, Sun-Woo;Yi, Jin-Bock;Kim, Young-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.131-136
    • /
    • 2007
  • In this study, we developed an active ankle-foot orthosis(AAFO) which can control dorsi/ plantar flexion of the ankle joint to prevent foot drop and toe drag during walking. 3D gait analyses were performed on five healthy subjects under three different gait conditions: the normal gait without AFO, the SAFO gait with the conventional plastic AFO, and the AAFO gait with the developed AFO. As a result, the developed AAFO preeminently induced the normal gait compared to the SAFO. Additionally, AAFO prevented foot drop by proper plantarflexion during loading response and provided enough plantarflexion moment as a driving force to walk forward by sufficient push-off during pre-swing. AAFO also could prevent toe drag by proper dorsiflexion during swing phase. These results indicate that the developed AAFO may have more clinical benefits to treat foot drop and toe drag, compared to conventional AFOs, and also may be useful in patients with other orthotic devices.

Soundness evaluation of friction stir welded A2024 alloy by non-destructive test (비파괴검사에 의한 A2024 마찰교반용접부의 건전성 평가)

  • Ko, Young-Bong;Kim, Gi-Beom;Park, Kyeung-Chae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.135-143
    • /
    • 2013
  • Friction Stir Welding (FSW) was developed, it is successfully commercialized in the field of transportation vehicles. In this study, we analyzed the defects of A2024-T4 alloy using non-destructive test of radiograph, ultrasonic, electrical conductivity and destructive test of microstructure observation, tensile strength. As the results of experiment, mapping of defects was obtained. Fine defects which were not detected in radiograph test were detected in ultrasonic test, and it enabled efficient detection of defects by difference of sound pressure and color. The values of electrical conductivity was decreased as amount of defects was increasing. Joint efficient of defect-free weldment that found by non-destructive and destructive test was 91%. Therefore it was considered that non-destructive test of friction stir welded A2024-T4 Alloy was an efficient method.

Statistical Precoder Design for Spatial Multiplexing Systems in Correlated MIMO Fading Channels (높은 안테나 상관도를 갖는 다중입출력 공간 다중화 시스템을 위한 통계적 프리코딩 기법)

  • Moon, Sung-Hyun;Kim, Jin-Sung;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3A
    • /
    • pp.223-231
    • /
    • 2011
  • It has been shown that the performance of multiple-input multiple-output (MIMO) spatial multiplexing systems is significantly degraded when spatial correlation exists between transmit and receive antenna pairs. In this paper, we investigate designs of a new statistical precoder for spatial multiplexing systems with maximum likelihood (ML) receiver which requires only correlation statistics at the transmitter. Two kinds of closed-form solution precoders based on rotation and power allocation are proposed by means of maximizing the minimum E tlidean distance of joint symbol constellations. In addition, we extend our results to linear receivers for correlated channels. We provide a method which yields the same profits from the proposed precoders based on a simple zero-forcing (ZF) receiver. The simulation shows that 2dB and 8dB gains are achieved for ML and ZF systems with two transmit antennas, respectively, compared to the conventional systems.

Monitoring of Microorganisms in Commercial Liquid Pig Manures in Korea (국내 유통 돈분 액비의 미생물 함량 모니터링)

  • Lim, Seong-Mook;Lee, Ji-Ho;Go, Woo-Ri;Kunhikrishnan, Anitha;Kim, Won-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1181-1184
    • /
    • 2011
  • Total aerobic bacteria, Esherichia coli O157:H7, and Salmonella spp. were examined in commercial liquid pig manures. Commercial liquid pig manures (n=33) were collected from muck joint resource recovery plant at April, June, August, October 2009, Korea. Total aerobic bacteria were incubated at $37^{\circ}C$ for 24-48 hrs, and quantified as a colony-forming unit (CFU) $mL^{-1}$. Analysis of Esherichia coli O157:H7 and Salmonella spp. were followed by Korean Food Standards Codex method. Colony of Salmonella spp. was confirmed by API kit and real time polymerase chain reaction (PCR). Total aerobic bacteria isolated from fermented commercial liquid pig manures ranged from 2.8 to $24.3{\times}10^4\;CFU\;mL^{-1}$. Esherichia coli O157:H7 was not detected, and Salmonella spp. showed the low detection frequency at only 1 sample. This study suggests that continuous monitoring in commercial liquid pig manures is required to improve the agricultural food through management of agricultural land contaminated with liquid pig manures.

Application of power spectral density function for damage diagnosis of bridge piers

  • Bayat, Mahmoud;Ahmadi, Hamid Reza;Mahdavi, Navideh
    • Structural Engineering and Mechanics
    • /
    • v.71 no.1
    • /
    • pp.57-63
    • /
    • 2019
  • During the last two decades, much joint research regarding vibration based methods has been done, leading to developing various algorithms and techniques. These algorithms and techniques can be divided into modal methods and signal methods. Although modal methods have been widely used for health monitoring and damage detection, signal methods due to higher efficiency have received considerable attention in various fields, including aerospace, mechanical and civil engineering. Signal-based methods are derived directly from the recorded responses through signal processing algorithms to detect damage. According to different signal processing techniques, signal-based methods can be divided into three categories including time domain methods, frequency domain methods, and time-frequency domain methods. The frequency domain methods are well-known and interest in using them has increased in recent years. To determine dynamic behaviours, to identify systems and to detect damages of bridges, different methods and algorithms have been proposed by researchers. In this study, a new algorithm to detect seismic damage in the bridge's piers is suggested. To evaluate the algorithm, an analytical model of a bridge with simple spans is used. Based on the algorithm, before and after damage, the bridge is excited by a sine force, and the piers' responses are measured. The dynamic specifications of the bridge are extracted by Power Spectral Density function. In addition, the Least Square Method is used to detect damage in the bridge's piers. The results indicate that the proposed algorithm can identify the seismic damage effectively. The algorithm is output-only method and measuring the excitation force is not needed. Moreover, the proposed approach does not need numerical models.

A Study on the Effective Countermeasures for Preventing Computer Security Incidents (기업의 침해사고 예방을 위한 관리 모델)

  • Kang, Shin-Beom;Lee, Sang-Jin;Lim, Jong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.1
    • /
    • pp.107-115
    • /
    • 2012
  • The level of information protection is relatively low, in comparison with the informatisation in this country. The budget for information protection is also quite marginal at 5% of the entire information-related policy budget. The passive information protection practices by companies, which focus more on the aftermaths, lead to repeated expenses for risk management. The responses to the violation of information protection should be changed from the current aftermaths-oriented focus to prevention and early detection of possible violations. We should also realize that the response to a violation of protected information is not a responsibility of an individual but a joint responsibility of the nation and the industry. South Korea has been working towards to building a systematic foundation since 2004 when guidelines were announced regarding the information protection policy and the safety diagnosis. The current level of safety policies cannot provide a perfect protection against actual violation cases in administrative, technological and physical ways. This research evaluates the level of prevention that the current systematic protection policy offers, and discusses its limitation and possible ways for improvement. It also recommends a list effective measures for protection against information violation that companies can employ to maintain the actual target safety level.

Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review

  • Giorgio Breda;Gianluca De Marco;Pierfranco Cesaraccio;Paolo Pillastrini
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.182-190
    • /
    • 2023
  • Elbow traumas represent a relatively common condition in clinical practice. However, there is a lack of evidence regarding the most accurate tests for screening these potentially serious conditions and excluding elbow fractures. The purpose of this investigation was to analyze the literature concerning the diagnostic accuracy of clinical tests for the detection or exclusion of suspected elbow fractures. A systematic review was performed using the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines. Literature databases including PubMed, Cumulative Index to Nursing and Allied Health Literature, Diagnostic Test Accuracy, Cochrane Library, the Web of Science, and ScienceDirect were searched for diagnostic accuracy studies of subjects with suspected traumatic elbow fracture investigating clinical tests compared to imaging reference tests. The risk of bias in each study was assessed independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 checklist. Twelve studies (4,485 patients) were included. Three different types of index tests were extracted. In adults, these tests were very sensitive, with values up to 98.6% (95% confidence interval [CI], 95.0%-99.8%). The specificity was very variable, ranging from 24.0% (95% CI, 19.0%-30.0%) to 69.4% (95% CI, 57.3%-79.5%). The applicability of these tests was very high, while overall studies showed a medium risk of bias. Elbow full range of motion test, elbow extension test, and elbow extension and point tenderness test appear to be useful in the presence of a negative test to exclude fracture in a majority of cases. The specificity of all tests, however, does not allow us to draw useful conclusions because there was a great variability of results obtained.