• Title/Summary/Keyword: jang

Search Result 60,035, Processing Time 0.092 seconds

The color stability and antibacterial of provisional polyethyl methacrylate (PEMA) resin with zirconia nanoparticles (지르코니아 나노입자 첨가된 PEMA (Polyethyl Methacrylate)레진 표면의 색안정성 및 항균평가)

  • Kim, Hee-Seon;Lee, Seon-Ki;Jang, Woohyung;Park, Chan;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.18-25
    • /
    • 2022
  • Purpose: This study aimed to evaluate the color stability and antibacterial properties of the surface of polyethyl methacrylate (PEMA) resin with zirconia nanoparticles added. Materials and Methods: The control group was pure PEMA resin, and the experiment group was PEMA resin 15 mm in diameter and 2.5 mm in thickness disk-shaped specimens with 2, 4 and 8 w/v% of zirconia nanoparticles added, which were respectively divided into Group Z2, Group Z4, and Group Z8. After analyzing the surface roughness and color stability of the specimens, their antibacterial properties were evaluated using Porphyromonas gingivalis (P. gingivalis). The Statistical analysis was performed using when normality was met in the Shapiro-Wilk test, one-way ANOVA was used to test parameters, and Tukey's test was used as a post hoc test. When normality was not met, the Kruskal-Wallis test, a non-parametric test was used (P < 0.05). Results: The surface roughness measurement found that there was no significant difference between the experimental and control groups. The color stability evaluation showed that the Z2, Z4, and Z8 groups were within the color range of natural teeth. The adhesion of P. gingivalis was evaluated to be significantly reduced in Group Z2 compared to the control group (P < 0.05). In the Z2 group, Z4 group, and Z8 group, dead cells bacteria than the control group were observed. Conclusion: In conclusion, PEMA resin with zirconia nanoparticles added was within the range of natural teeth in color and reduced the adhesion of P. gingivalis.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.

Arthroscopically-Assisted Reduction and Internal Fixation of Intra-Articular Fractures of the Lateral Tibial Plateau (관절면을 침범한 경골 외측 고평부 골절에 대한 관절경을 이용한 정복 및 내고정술)

  • Kim, Juhan;Kim, Dong Hwi;Lim, Jae-Hwan;Jang, Hyunwoong;Kim, Young Wook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.227-236
    • /
    • 2019
  • Purpose: To evaluate the results of tibial lateral plateau fractures using arthroscopic-assisted reduction and internal fixation without cortical window or bone grafts. Materials and Methods: From March 2009 to March 2017, 27 patients with Schatzker type II tibial plateau fractures with articular depression and displacement over 5 mm on a computed tomography (CT) scan, who were treated with arthroscopic reduction and internal fixation and followed-up for at least 18 months, were enrolled in this study. Under arthroscopic guidance, the depressed fracture fragment was reduced using a freer and fixed with 5.0 or 6.5 mm cannulated screws through the inframeniscal portal without a cortical window or bone graft. The clinical and radiological results were evaluated using a Rasmussen system. Second look arthroscopy was performed in thirteen patients during the implant removal operation. Results: All fractures healed completely with a mean union time of 8.7 weeks (range from 8 to 12 weeks). Twenty four patients had good to excellent clinical results and 25 patients had good to excellent radiological results according to the Rasmussen classification. A well-healed articular surface with fibrocartilage was also found in 13 cases with second look arthroscopy. The 8 cases on CT scan at outpatient department follow-up showed bone union without bone grafting. Conclusion: Arthroscopic-assisted fixation of tibial lateral plateau fractures is a useful method without a cortical window or bone graft that produces good clinical results.

Evaluation of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria (LG AdvansureTM Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성)

  • Lee, Hye Jin;Kim, Ha Nui;Yoo, Byong Joon;Kim, Jang Su;Kim, Myong Han;Lim, Chae Seung;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.2
    • /
    • pp.100-104
    • /
    • 2011
  • Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR (LG life sciences, Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection, N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG AdvansureTM Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG AdvansureTM Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG AdvansureTM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

Evaluation of ABO Antibody Titration Using Tube and Column Agglutination Techniques (ABO 동종 응집소 역가 측정을 위한 시험관 및 미세원주응집법의 평가)

  • Cho, Chi-Hyun;Kim, Ha-Nui;Yun, Seung-Gyu;Choi, Gye-Ryung;Choi, Jae-Yeoul;Kim, Jang-Su;Lim, Chae-Seung;Kim, Young-Kee;Lee, Kap-No
    • Laboratory Medicine Online
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Background: ABO antibody titration is useful for the evaluation of ABO-incompatible bone marrow or solid organ transplantations, yet the results quite vary between different test methods used. We compared the results of microcolumn agglutination and tube methods. Methods: Anti-A and anti-B isoagglutionin titers were determined in 63 healthy individuals (23 O, 20 A, and 20 B blood groups) using 4 different methods: immediate spin tube (tube), microcolumn agglutination without anti-human globulin (AHG) (CAT), tube with AHG (tube-AHG) and microcolumn agglutination with AHG (CAT-AHG). Results: The median (range) titers of anti-A and anti-B in group O individuals by tube, CAT, tube-AHG, and CAT-AHG methods were 64 (8-512), 64 (8-512), 128 (8-2,048), and 128 (16-2,048); 64 (16-128), 128 (16-256), 128 (16-512), and 256 (16-512), respectively. The median (range) titers of anti-A in group B and anti-B in group A individuals by the four methods were 64 (16-128), 128 (8-128), 128 (8-256), and 256 (8-256); 64 (8-128), 64 (8-128), 32 (8-128), and 64 (8-256), respectively. The isoagglutinin titer measured by CAT-AHGmethod was the highest. The titers measured by CAT and CAT-AHG methods were 0-1 titer higher than those by tube and tube-AHG methods, respectively. Whatever method was used, the isoagglutinin titers were higher in women than in men. Conclusions: CAT-AHG was the most sensitive method among the four methods tested. Since AHG titer values are critical for the clinical management and CAT has less manual procedures than tube method, CAT-AHG method could be used for the standardization of ABO antibody titration in different institutions.

A Study on Utility of the Specialized Exhibition Using IT Technology - Focussing on Attendees including On-line Invitation Visitors - (IT기술을 이용한 전문 전시회의 효용성에 대한 연구 - 온라인 초청 관람객을 포함한 관람객을 중심으로 -)

  • Kim, Young Soo;Joe, Yong Geun;Jang, Yoon Jeong;Yoo, Hee Eun;Kim, Kyung Hoon
    • Korea Science and Art Forum
    • /
    • v.21
    • /
    • pp.105-116
    • /
    • 2015
  • This study intended to give helps in planning a specialized exhibition by carrying out a survey objecting to KOREA PACK 2015 attendees including visitors who possessed mobile coupons after finishing advance registration through on-line, and then investigating, analyzing satisfactions of attendees together with effects of the specialized exhibition using IT technology. As a lot of relevant preceeding researches have been made by focussing on exhibition organizer and exhibitors, the viewpoints of attendees at the specialized exhibition using IT conversing technology such as mobile and etc. were to be investigated and analyzed. Thus, this research tried to do an empirical identification on effects of the exhibition by analyzing relations between its watching forms and satisfactions including a survey on the on-line PR route utility of IT technology in addition to visiting motives of attendees who watched the exhibition. A summarization of the current study is followed: First, in case of attending in the exhibition for specific purposes, they searched related information positively, and were shown as doing information gathering behaviors and also high possibility on purchases was confirmed. Second, it was confirmed that positive attendees had decision-making on purchases. This finding means that attendees who watch the specialized exhibition have authority and responsibility of being able to purchase in many cases, so methods of improving sales by effectively doing PR on own products and technical competitiveness in the exhibition are necessary to exhibitors. Third, attendees who have specific purposes showed higher satisfactions on the exhibition than general visitors, but satisfactions on consultation, staff attitudes, and facility were turn out to be higher than providing related information on products or technology. Accordingly, the necessity of improving this outcome was confirmed. Therefore, exhibitors have to endeavor in providing more advanced services to attendees of the exhibition by grasping technical trends in advance as well as cultivating professional staff who can promote products well.

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Research Trends of Health Recommender Systems (HRS): Applying Citation Network Analysis and GraphSAGE (건강추천시스템(HRS) 연구 동향: 인용네트워크 분석과 GraphSAGE를 활용하여)

  • Haryeom Jang;Jeesoo You;Sung-Byung Yang
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.2
    • /
    • pp.57-84
    • /
    • 2023
  • With the development of information and communications technology (ICT) and big data technology, anyone can easily obtain and utilize vast amounts of data through the Internet. Therefore, the capability of selecting high-quality data from a large amount of information is becoming more important than the capability of just collecting them. This trend continues in academia; literature reviews, such as systematic and non-systematic reviews, have been conducted in various research fields to construct a healthy knowledge structure by selecting high-quality research from accumulated research materials. Meanwhile, after the COVID-19 pandemic, remote healthcare services, which have not been agreed upon, are allowed to a limited extent, and new healthcare services such as health recommender systems (HRS) equipped with artificial intelligence (AI) and big data technologies are in the spotlight. Although, in practice, HRS are considered one of the most important technologies to lead the future healthcare industry, literature review on HRS is relatively rare compared to other fields. In addition, although HRS are fields of convergence with a strong interdisciplinary nature, prior literature review studies have mainly applied either systematic or non-systematic review methods; hence, there are limitations in analyzing interactions or dynamic relationships with other research fields. Therefore, in this study, the overall network structure of HRS and surrounding research fields were identified using citation network analysis (CNA). Additionally, in this process, in order to address the problem that the latest papers are underestimated in their citation relationships, the GraphSAGE algorithm was applied. As a result, this study identified 'recommender system', 'wireless & IoT', 'computer vision', and 'text mining' as increasingly important research fields related to HRS research, and confirmed that 'personalization' and 'privacy' are emerging issues in HRS research. The study findings would provide both academic and practical insights into identifying the structure of the HRS research community, examining related research trends, and designing future HRS research directions.

Effect of Heavy Metals (As, Cr, Pb) on the Population Growth Rates of Marine Diatom, Skeletonema castatum (중금속(As, Cr, Pb)이 해산 규조류(Skeletonema costatum)의 개체군 성장률에 미치는 영향)

  • Lee, Ju-Wook;Ryu, Hyang-Mi;Heo, Seung;Jang, Soo-Jung;Lee, Ki-won;Hwang, Un-Ki
    • Journal of Marine Life Science
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2017
  • In this study, we evaluated the toxic effects of heavy metals (As, Cr and Pb) on the population growth rate (r) of the marine diatom, Skeletonema costatum. The r of the species was determined after 96 h (4 days) exposure to As (0, 0.31, 0.63, 1.25, 2.50 and 5.00 mg L-1), Cr (0, 0.16, 0.31, 0.63, 1.25 and 2.50 mg L-1) and Pb (0, 1.25, 2.50, 5.00, 10.00 and 20.00 mg L-1). It was observed that r in the control (absence of As, Cr and Pb) were greater than 0.04, however suddenly decreased with increased heavy metal concentrations. As, Cr and Pb reduced r in a dose-dependent manner and a significant reduction were occurred at concentration of greater than 0.31, 0.31 and 5.00 mg L-1, respectively. Based on the toxicity, the heavy metal were ranked as Cr>As>Pb, with EC50 (50% effective concentration) values of 0.80, 2.57 and 13.88 mg L-1, respectively. The lowest-observed-effective-concentration (LOEC) of r in exposed to As, Cr and Pb were 0.63, 0.63 and 10.00 mg L-1, respectively. Precisely, a concentration of greater than 0.63 mg L-1 of As, 0.63 mg L-1 of Cr and 10.00 mg L-1 of Pb in marine ecosystems induced toxic effect on the r of S. costatum. Based on our results, we suggested that the r of S. costatum might be a useful bio-indicator for the toxicity assessment of heavy metals on the producer in marine ecosystems.

Evaluation of Robustness of Deep Learning-Based Object Detection Models for Invertebrate Grazers Detection and Monitoring (조식동물 탐지 및 모니터링을 위한 딥러닝 기반 객체 탐지 모델의 강인성 평가)

  • Suho Bak;Heung-Min Kim;Tak-Young Kim;Jae-Young Lim;Seon Woong Jang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.297-309
    • /
    • 2023
  • The degradation of coastal ecosystems and fishery environments is accelerating due to the recent phenomenon of invertebrate grazers. To effectively monitor and implement preventive measures for this phenomenon, the adoption of remote sensing-based monitoring technology for extensive maritime areas is imperative. In this study, we compared and analyzed the robustness of deep learning-based object detection modelsfor detecting and monitoring invertebrate grazersfrom underwater videos. We constructed an image dataset targeting seven representative species of invertebrate grazers in the coastal waters of South Korea and trained deep learning-based object detection models, You Only Look Once (YOLO)v7 and YOLOv8, using this dataset. We evaluated the detection performance and speed of a total of six YOLO models (YOLOv7, YOLOv7x, YOLOv8s, YOLOv8m, YOLOv8l, YOLOv8x) and conducted robustness evaluations considering various image distortions that may occur during underwater filming. The evaluation results showed that the YOLOv8 models demonstrated higher detection speed (approximately 71 to 141 FPS [frame per second]) compared to the number of parameters. In terms of detection performance, the YOLOv8 models (mean average precision [mAP] 0.848 to 0.882) exhibited better performance than the YOLOv7 models (mAP 0.847 to 0.850). Regarding model robustness, it was observed that the YOLOv7 models were more robust to shape distortions, while the YOLOv8 models were relatively more robust to color distortions. Therefore, considering that shape distortions occur less frequently in underwater video recordings while color distortions are more frequent in coastal areas, it can be concluded that utilizing YOLOv8 models is a valid choice for invertebrate grazer detection and monitoring in coastal waters.