• 제목/요약/키워드: isolation source

검색결과 559건 처리시간 0.028초

SEISMIC ISOLATION OF NUCLEAR POWER PLANTS

  • Whittaker, Andrew S.;Kumar, Manish;Kumar, Manish
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.569-580
    • /
    • 2014
  • Seismic isolation is a viable strategy for protecting safety-related nuclear structures from the effects of moderate to severe earthquake shaking. Although seismic isolation has been deployed in nuclear structures in France and South Africa, it has not seen widespread use because of limited new build nuclear construction in the past 30 years and a lack of guidelines, codes and standards for the analysis, design and construction of isolation systems specific to nuclear structures. The funding by the United States Nuclear Regulatory Commission of a research project to the Lawrence Berkeley National Laboratory and MCEER/University at Buffalo facilitated the writing of a soon-to-be-published NUREG on seismic isolation. Funding of MCEER by the National Science Foundation led to research products that provide the technical basis for a new section in ASCE Standard 4 on the seismic isolation of safety-related nuclear facilities. The performance expectations identified in the NUREG and ASCE 4 for seismic isolation systems, and superstructures and substructures are described in the paper. Robust numerical models capable of capturing isolator behaviors under extreme loadings, which have been verified and validated following ASME protocols, and implemented in the open source code OpenSees, are introduced.

Application of an Efficient Method for Isolation of Mitochondria from Biological Samples

  • Jun, Jin Hyun;Kim, Jihyun;Kim, Kyung Tae;Sung, Ho Joong
    • Biomedical Science Letters
    • /
    • 제20권3호
    • /
    • pp.180-184
    • /
    • 2014
  • Mitochondria play a crucial role in many essential biological events by way of the electron transport chains and intermembrane proteins that they contain. Abnormalities in the mitochondria are strongly correlated with the development of diseases such as atherosclerosis, cancer, and diabetes. However, the study of mitochondria has been referred to as 'labor-intensive' because of the difficulty in isolating the organelles from their various sources, which can include cultured cells and tissues. Multiple companies provide mitochondria isolation kits, and it is possible for investigators to use different kits and apply different protocols depending on the source of the mitochondria. Therefore, we focused on producing an isolation buffer that could be applied to both cultured cells and tissues, and optimized an isolation protocol that could be used with both. Specifically, we adjusted the buffer condition that can be applied to human cervical cancer cells, fibroblasts, and tissues such as mouse liver and spleen. We also optimized the protocol to improve the efficacy and efficiency of the steps involved in the isolation of mitochondria. These methodological improvements may contribute to advanced research by allowing investigators to overcome the difficulties involved in isolation of mitochondria from biological samples.

Fault Isolation for Linux Device Drivers

  • Son, Sunghoon
    • Journal of the Korea Society of Computer and Information
    • /
    • 제22권4호
    • /
    • pp.1-8
    • /
    • 2017
  • In this paper, we propose a fault isolation system for device drivers of the Linux operating system. High availability systems impose stringent requirements upon Linux operating system. Especially device drivers can be a major source of operating system instability and many times contribute to system degradation and outages. The proposed fault isolation system identifies the occurrence of the memory-related faults in device driver and isolates it from the kernel. By operating at the early stage of the page fault handler in Linux kernel, the system detects which module causes fault and isolates it transparently from the remaining part of the kernel. By experiments, we show that the proposed system efficiently detects faults incurred by device driver, isolates the device driver and the process which accessed the driver module from the kernel.

Equivalent Stiffness Modeling of Isolators to Consider Wave Effects in Multi-dimensional Vibration Isolation Analysis, via Vibrational Power (진동파워를 이용한 다차원 진동절연계 해석시 절연요소의 파동효과를 고려한 등가강성화)

  • 최규상;이호정;김광준
    • Journal of KSNVE
    • /
    • 제9권3호
    • /
    • pp.517-524
    • /
    • 1999
  • Mathematical formulas for multi-dimensional isolation analysis via vibrational power transmission can be derived in a rather simple form when the wave effects of the isolators are completely neglected. With increase of frequency range of interest, however, the wave effects play a very important role and hence cannot be neglected. The formulas get involved accordingly. In this study, a method of equivalent stiffness modeling of the isolators to include the wave effects is proposed in such a way that not only the complexity of the mathematical expressions but also that of experiments of necessity can be reduced. This method is illustratively applied to a two-dimensional vibration isolation system with nonrigid source and base structures.

  • PDF

Micro-vibration Isolation Performance Verification for the Passive Vibration Isolator using SMA Mesh Washer (SMA 메쉬 와셔를 적용한 수동형 진동절연기의 미소진동 절연성능 검증)

  • Kwon, Sung-Cheol;Jeon, Su-Hyeon;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.900-903
    • /
    • 2014
  • Fly-wheel, Gimbal antenna, CMG, Spaceborne cyrocooler generate micro-vibration during their on-orbit operation as well as implementing their own function. To comply with the mission requirement of high resolution observation satellite, additional technical efforts have been required to isolate the micro-vibration derived from such payloads by applying the vibration isolator. In this study, we proposed a passive isolator using SMA mesh washer, which guarantees the structural safety of both micro-vibration disturbance source and itself under harsh launch vibration loads without an additional holding mechanism and the micro-vibration isolation performance on orbit environment. To verify the micro-vibration isolation performance of the proposed vibration isolator, we performed the micro-vibration isolation measurement test using the dedicated micro-vibration measurement device proposed in this study.

  • PDF

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

Isolation and Structure Determination of a Proteasome Inhibitory Metabolite from a Culture of Scytonema hofmanni

  • Shim, Sang-Hee;Chlipala, George;Orjala, Jimmy
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권10호
    • /
    • pp.1655-1658
    • /
    • 2008
  • Cyanobacteria, blue-green algae, are a rich source of bioactive secondary metabolites with many potential applications. The ubiquitin-proteasome proteolytic system plays an important role in selective protein degradation and regulates cellular events including apoptosis. Cancer cells are more sensitive to the proapoptotic effects of proteasome inhibition than normal cells. Thus, proteasome inhibitors can be potential anticancer agents. Cyanobacteria have been shown to be a rich source of highly effective inhibitors of proteases. A proteasome inhibitor was screened from an extract of the culture of Scytonema hofmanni on the basis of its inhibitory activity, which led to the isolation of nostodione A with an $IC_{50}$ value of 50${\mu}M$. Its structure was determined by spectroscopic methods such as $^{1}H$-NMR and ESI-MS spectral analyses.

Correlation between Dynamic Characteristics of Isolation Material and Impact Noise Reduction of Light-weight Impact Source (충격음 저감재의 동특성과 실험실 경량충격음레벨 저감량의 상관관계)

  • 이주원;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.191-195
    • /
    • 2003
  • 충격음 저감재의 동탄성계수와 감쇠계수는 차단성능을 평가하는데 있어 중요한 물성치가 된다. 저감재의 동탄성계수는 뜬바닥구조의 고유진동수를 결정짓게 되며, 저감재의 동탄성계수가 높을수록, 즉 고유진동수가 높아짐에 따라 실험실 경량충격음레벨 저감량은 지수함수적으로 감소됨을 실험을 통해 알 수 있다. 또한, 저감재를 포함한 뜬바닥구조를 1자유도 진동계로 가정한 이론값과 실험실 경량충격음레벨 저감량의 결과가 비교적 잘 일치하는 것으로 나타났으며, 이 때 감쇠계수의 영향은 반드시 고려되어야 한다.

  • PDF

Numerical Feasibility Study for a Spaceborne Cooler Dual-function Energy Harvesting System

  • Kwon, Seong-Cheol;Oh, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.579-587
    • /
    • 2017
  • Spaceborne cryocoolers produce undesirable micro-vibration disturbances during their on-orbit operation, which are a primary source of image-quality degradation for high-resolution observation satellites. Therefore, to comply with the strict mission requirement of high-quality image acquisition, micro-vibration disturbances induced by cooler operation have always been subjected to an isolation objective. However, in this study, we focused on the applicability of energy harvesting technology to generate electrical energy from micro-vibration energy of the cooler and investigated the feasibility of utilizing harvested energy as a power source to operate low-power-consumption devices such as micro-electromechanical system (MEMS) devices. A tuned mass damper (TMD)-type electromagnetic energy harvester combined with a conventional passive vibration isolator was proposed to achieve this objective. The system performs the dual functions of electrical energy generation and micro-vibration isolation. The effectiveness of the strategy was evaluated through numerical simulations.

A method of isolation and characterization of canine endometrial-derived mesenchymal stem cells

  • Mi Kyung Park;Kun Ho Song
    • Korean Journal of Veterinary Service
    • /
    • 제46권2호
    • /
    • pp.157-160
    • /
    • 2023
  • Endometrial tissue is a known source of mesenchymal stem cells (MSCs). We isolated canine endometrial stem cells from canine endometrial tissues using an enzymatic method and confirmed the immunophenotype of mesenchymal stem cells and multilineage differentiation. Canine endometrial tissues were obtained from canine ovariohysterectomy surgery and isolated using 0.2% collagenase type I. We measured the immunophenotype of stem cells using flow cytometry. To confirm the differentiation ability, a trilineage differentiation assay was conducted. In this study, canine endometrialderived MSCs (cEM-MSCs) were isolated by enzyme treatment and showed a spindle-shaped morphology under a microscope. Moreover, cEM-MSCs showed a trilineage differentiation ability. In this study, the canine endometrium was a good source of MSCs.