폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구 (The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip)

  • 양관섭;이세현;김홍열;김승민
    • 소음진동
    • /
    • 제9권3호
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

Design and analysis of isolation effectiveness for three-dimensional base-seismic isolation of nuclear island building

  • Zhu, Xiuyun;Lin, Gao;Pan, Rong;Li, Jianbo
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.374-385
    • /
    • 2022
  • In order to investigate the application of 3D base-seismic isolation system in nuclear power plants (NPPs), comprehensive analysis of constitution and design theory for 3-dimensional combined isolation bearing (3D-CIB) was presented and derived. Four different vertical stiffness of 3D-CIB was designed to isolate the nuclear island (NI) building. This paper aimed at investigating the isolation effectiveness of 3D-CIB through modal analysis and dynamic time-history analysis. Numerical results in terms of dynamic response of 3D-CIB, relative displacement response, acceleration and floor response spectra (FRS) of the superstructure were compared to validate the reliability of 3D-CIB in mitigating seismic response. The results showed that 3D-CIB can significantly attenuate the horizontal acceleration response, and a fair amount of the vertical acceleration response reduction of the upper structure was still observed. 3D-CIB plays a significant role in reducing the horizontal and vertical FRS, the vertical FRS basically do not vary with the floor height. The smaller the vertical stiffness of 3D-CIB is, the better the vertical isolation effectiveness is, whereas, it will increase the displacement and the rocking effect of superstructure. Although the advantage of 3D-CIB is that the vertical stiffness can be flexibly adjusted, it should be designed by properly accounting for the balance between the isolation effectiveness and displacement control including rocking effect. The results of this study can provide the technical basis and guidance for the application of 3D-CIB to engineering structure.

LQG design scheme for multiple vibration controllers in a data center facility

  • Kohiyama, Masayuki;Yoshida, Minako
    • Earthquakes and Structures
    • /
    • 제6권3호
    • /
    • pp.281-300
    • /
    • 2014
  • This study proposes a scheme to design control parameters for a data center facility with a vibration controller on its top floor and a secondary isolation device with its own vibration controller designed to protect vibration-sensitive computer equipment. The aim is to reduce the effects of acceleration and drift from an earthquake on computer servers placed on the isolation device that must operate during a seismic event. A linear elastic model is constructed and the evaluation function of the linear quadratic Gaussian (LQG) control is formulated. The relationship between the control parameters and the responses is examined, and based on the observations, a control parameter design scheme is constructed to reduce the responses of both the building and the computer server effectively.

라멘복합구조 공동주택의 바닥충격음 실태 (Investigation of Floor Impact Sound Levels in Rahmen Structure Multi-story Residential Buildings)

  • 정정호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.308-311
    • /
    • 2004
  • It is reported that there is a limit in increasing heavy-weight impact noise isolation performance of the load bearing wall system apartments to meet the regulation of the Ministry of Construction and Transportation (MOCT). To increase the heavy-weight impact noise isolation performance, improvement in structural systems such as increasing concrete slab thickness and application of rahmen structure were proposed. In this study floor impact sound levels from toil apartments with two rahmen structure multi-story residential buildings were measured before the construction of the buildings finished. Measurements were made at living room and two bedrooms at each apartment when the finishing processes were finished. The average value of light-weight impact sound level from ten apartments was 56dB (L'$\sub$n,Aw/). The heavy-weight impact sound level was 44dB (L'$\sub$i.Fmax.Aw/) and the impact sound level of the impact ball was 41dB(L'$\sub$i.Fmax.Aw/), As a result floor impact noises at the rahmen structure system were lower than the regulation level.

  • PDF

A Teleoperated Cleaning Robot for a High Radioactive Environment

  • Kim, Ki-Ho;Park, Jang-Jin;Yang, Myung-Seung;Oh, Chae-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.849-854
    • /
    • 2003
  • The Korea Atomic Energy Research Institute has developed a teleoperated cleaning robot for use in the radioactive zone of the isolation room of the Irradiated Material Examination Facility where direct human access to the interior is strictly limited. The teleoperated cleaning robot that was designed to completely eliminate human interaction with the hazardous radioactive contaminants has five remotely replaceable submodules - a mobile module for navigation, a cleaning module for dislodging and sucking contaminated waste, a sensing module for obstacle avoidance, a collection module for storing the acquired waste, and a cover module for protecting the collection module. This cleaning robot is capable of cleaning the contaminated floor surface of the isolation room and collecting loose dry spent nuclear fuel debris and other radioactive waste fixed or scattered on the floor surface. The developed cleaning robot is operated either by a manual control or by autonomous control in conjunction with a graphical simulator, by which the human operator can monitor and intervene the robot performing cleanup tasks in the isolation room. In this paper, we present the mechanical and environmental design considerations and development of the teleoperated cleaning robot for radioactive isolation room use. We also demonstrate its mock-up performance test results from the viewpoint of a remote cleanup operation and remote maintenance.

  • PDF

주상복합건물에 대한 면진기술의 적용 (Application of Seismic Isolation Technique in Residential-Commercial Building)

  • 이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.465-472
    • /
    • 2000
  • Seismic isolation technique has been applied mainly in low rise buildings and its seismic performance was satisfactory during Kobe Earthquake. However, in the case of medium and/or high-rise buildings, mid-story isolation could be more technically feasible than base isolation to reduce earthquake forces. In this paper, the seismic effectiveness of mid-story isolation in medium and/or high-rise shear building as well as low rise shear building was evaluated analytically. After verifying the effectiveness of mid-story isolation technique, this method also applied in residential-commercial building. It was found that mid-story isolation, that is isolation between upper residential area and lower commercial area, could reduce inter-story drift and floor shear forces comparing to the conventional fixed base.

  • PDF

면진원전의 층응답스펙트럼 해석 (Floor Response Spectrum Analysis of a Base-isolated Nuclear Power Plant)

  • 정재욱;이상민;홍정욱
    • 한국전산구조공학회논문집
    • /
    • 제29권4호
    • /
    • pp.355-362
    • /
    • 2016
  • 대규모 지진에 대한 원전의 안전성을 확보하는 방안으로 기존 원전 구조물에 면진장치를 설치하는 방안이 도입되고 있다. 면진장치를 설치함으로써 상부구조와 지반의 거동을 격리시킬 수 있고, 구조물 자체의 고유주기가 길어지게 되는데, 이를 통해 지진하중에 대한 구조물의 응답을 감소시킬 수 있게 된다. 특히 원전구조물 설계 시 원전구조물 자체뿐만 아니라 원전 내부 기기에 대한 안전성 확보가 필수적이다. 이를 위해 특정 층에 위치한 기기의 설계를 위해 각 층의 최대 요구 응답을 나타내는 층응답스펙트럼이 일반적으로 사용된다. 본 논문에서는 원전 구조물의 지진해석을 통해 특정 층의 층응답스펙트럼을 평가하고, 면진 장치의 거동 특성중 하나인 2차 경화에 대한 영향 또한 평가하였다.

바닥충격음에서의 천장구조에 따른 진동절연 효과 (Vibration isolation effect of floor impact sound by ceiling structure)

  • 이성호;정갑철;정진연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to evaluate factors of ceiling structure influencing to the floor impact sound. For this reasons, we measured the vibration of ceiling and the floor impact sound by ceiling structure. The main results from this study are that ceiling structure makes worse to non-ceiling structure for an effect of air layer in heavy-weight floor impact sound. But it has an effect on light-weight floor impact sound about $2\sim8dB$.

  • PDF

층간소음저감재 장기 내구성 평가를 위한 가열시험의 문제점 및 개선방안에 관한 연구 (A study on the improvement method of heat treatment condition for the long-term stability evaluation in the floor impact isolator)

  • 박연준;이찬규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.238-243
    • /
    • 2011
  • This study compared Kd, loss factor and thickness of floor impact isolator by loading/unloading heat treatment with results by continuous loading treatment and checked problem and improvement method of heat treatment condition for the long-term stability evaluation of the floor impact isolation. As the results, it is required the change of heat treatment condition unloading now to loading as actual weigh on the floor impact isolator.

  • PDF

감쇠재 사용에 따른 중량충격음의 소음 및 진동특성 (Noise and Vibration Characteristics of Heavy-weight floor impact by Using Damping Materials)

  • 전진용;정영;송희수;김민배;이영제
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.97-102
    • /
    • 2004
  • The Characteristics of noise and vibration by heavy-weight floor impact sound was studied. Resonance frequency increased a little in structures that use damping material in living room and bedroom, and acceleration waves length that respond became short, and displayed aspect that oscillation level decreases. Result that measure sound pressure level, structure that compare and applies damping materials with structure that apply the resilient materials from 63Hz lower part that impact energy is concentrated in energy spectrum of heavy-weight floor impact sound displayed result that sound pressure, level decreases remarkably. Therefore, according to use of damping materials, confirmed reduction effect of heavy-weight floor impact sound.

  • PDF