• Title/Summary/Keyword: irregular loading test

Search Result 38, Processing Time 0.026 seconds

Experimental Method for Durability Evaluation of a Chisel Mounted on a Composite Working Implement

  • Han, Jeongwoo;Moon, Sanggon;Lee, Geunho;Kang, Daesik
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.251-257
    • /
    • 2017
  • Purpose: A chisel mounted on working implement, such as agricultural machinery used in irregular farming conditions, is subjected to highly variable fatigue loading during work. To ensure the safety of the chisel on a working implement for the duration of its service life, fatigue testing must be performed with the proper fatigue test load conditions. In this study, working loads for a chisel were developed by reconstructing loads from strain gage data collected during field tests and used to conduct fatigue tests on the chisel component. Methods: FE analysis with nCode software was utilized to select the proper quantity and locations of strain gages for load measurements. A fatigue test was performed to experimentally verify the fatigue strength of the chisel and to evaluate the validity of the load history developed with the load reconstruction technique. Results: A strain history for the chisel was obtained from data collected during field tests. The data was filtered for the 14-16 km/h speed range, connected, and merged. The chisel load history was developed using the load reconstruction technique. The resulting load history was expressed as a load spectrum using the rain-flow counting method. Conclusions: A fatigue test was conducted on a chisel under a constant load condition with an equivalent load amplitude and number of cycles, as calculated by Miner's Rule for linear damage accumulation. During the fatigue test, there were no cracks at any position. It is concluded that the fatigue test method proposed in this study can be utilized successfully as a durability evaluation method for the chisel.

Seismic behavior of steel truss reinforced concrete L-shaped columns under combined loading

  • Ning, Fan;Chen, Zongping;Zhou, Ji;Xu, Dingyi
    • Steel and Composite Structures
    • /
    • v.43 no.2
    • /
    • pp.139-152
    • /
    • 2022
  • Steel-reinforced concrete (SRC) L-shaped column is the vertical load-bearing member with high spatial adaptability. The seismic behavior of SRC L-shaped column is complex because of their irregular cross sections. In this study, the hysteretic performance of six steel truss reinforced concrete L-shaped columns specimens under the combined loading of compression, bending, shear, and torsion was tested. There were two parameters, i.e., the moment ratio of torsion to bending (γ) and the aspect ratio (column length-to-depth ratio (φ)). The failure process, torsion-displacement hysteresis curves, and bending-displacement hysteresis curves of specimens were obtained, and the failure patterns, hysteresis curves, rigidity degradation, ductility, and energy dissipation were analyzed. The experimental research indicates that the failure mode of the specimen changes from bending failure to bending-shear failure and finally bending-torsion failure with the increase of γ. The torsion-displacement hysteresis curves were pinched in the middle, formed a slip platform, and the phenomenon of "load drop" occurred after the peak load. The bending-displacement hysteresis curves were plump, which shows that the bending capacity of the specimen is better than torsion capacity. The results show that the steel truss reinforced concrete L-shaped columns have good collapse resistance, and the ultimate interstory drift ratio more than that of the Chinese Code of Seismic Design of Building (GB50011-2014), which is sufficient. The average value of displacement ductility coefficient is larger than rotation angle ductility coefficient, indicating that the specimen has a better bending deformation resistance. The specimen that has a more regular section with a small φ has better potential to bear bending moment and torsion evenly and consume more energy under a combined action.

Experimental study on wave forces to offshore support structures

  • Jeong, Youn-Ju;Park, Min-Su;You, Young-Jun
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.193-209
    • /
    • 2016
  • In this study, wave force tests were carried out for the four types of offshore support structures with scale factor 1:25 and wave forces to the support structure shapes were investigated. As the results of this study, it was found that, as the wave period increased at the normal wave condition, wave force decreased for the most cases. Extreme wave force was affected by the impact wave force. Impact wave force of this study significantly effect on Monopile and slightly on GBS and Hybrid type. Accordingly, Hybrid type indicated even lower wave force at the extreme and irregular wave conditions than the Monopile although Hybrid type indicated higher wave force at the normal wave condition of the regular wave because of the larger wave area of wave body. In respects of the structural design, since critical loading is extreme wave force, it should be contributed to improve structural safety of offshore support structure. However, since the impact wave force has nonlinearity and complication dependent on the support structure shape, wave height, wave period, and etc., more research is needed to access the impact wave force for other support structure shapes and wave conditions.

Evaluation of Age-Hardening Characteristics of Squeeze-Cast A356 Alloy by Using Micro/Nano Indenter with AFM (나노/마이크로 인덴터와 AFM을 이용한 스퀴즈 캐스트 A356 합금의 시효경화특성 평가)

  • Youn S.W.;Kim K.D.;Kang C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1398-1401
    • /
    • 2005
  • The nano/microstructure, the aging response (in T5 heat treatment), and the mechanical/tribological properties of the eutectic regions in squeeze-cast A356 alloy were investigated using nano/micro-indentation and mechanical scratching, combined wit optical microscopy and atomic force microscope(AFM). Most eutectic Si crystals in the A356 alloy showed a modified morphology as fine-fibers. The loading curve for the eutectic region was more irregular than that of the primary Al region due to the presence of various particles of varying strength. In addition, the eutectic region showed lower pile-up and higher elastic recovery than the primary Al region. The aging responses of the eutectic regions in the squeeze-cast A356 alloys aged at $150^{\circ}C$ for different times(0, 2, 4, 8, 10, 16, 24, 36 and 72 h) were investigated. As the aging time increased, acicular Si particles in the eutectic regions gradually came to a fine structure. Both Vickers hardness ($H_V$) and indentation ($H_{IT}$) test results showed almost the same trend of aging curves, and the peak was obtained at the same aging time of 10 h. A remarkable size-dependence of the tests was found. The friction coefficient for the eutectic region was lower than that for the primary Al region.

  • PDF

Crushing Characteristics of Single Particle of Recycled Aggregate from Waste Concrete (폐콘크리트 순환골재의 단입자 파쇄 특성)

  • Park, Sung-Sik;Kim, Sang-Jung;Moon, Hong-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.12
    • /
    • pp.23-32
    • /
    • 2016
  • A single particle crushing test was carried out for recycled aggregates from waste concrete while demolishing various structures. When the recycled aggregates were used for backfill or road subbase materials, load-displacement and crushing characteristics were analyzed. The recycled aggregates with hydrates and aggregates were sorted into 40 mm size (75-40 mm) and 20 mm size (40-20 mm). At initial loading, their irregular surface was closed to and then crushed by loading plate. Such first crushing stage was called 'Surface crushing'. Further loading, some hydrate was crushed and detached from aggregate, and such process repeated several times. This state is called 'hydrate crushing'. The final state is called 'aggregate crushing' in which aggregate crushed and following load suddenly dropped down. As the load increased, such crushing cycle is repeated several times. The shapes of aggregates are round or square, and triangle or long shaped. Depending on their shapes and surface conditions, they crushed in different ways. The 63% of aggregates showed more than 50% load reduction due to aggregate crushing. The 90% load reduction occurred at 15% of aggregates. The 40 mm aggregate crushed at maximum load between 3.05-4.38 kN and 70% of crushed aggregates were less than 20 mm.

Crack Growth Behavior of Cement Composites by Fractal Analysis (시멘트 복합체의 균열성장거동에 관한 프랙탈 해석)

  • 원종필;김성애
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.146-152
    • /
    • 2001
  • The fractal geometry is a non-Euclidean geometry which discribes the naturally irregular or fragmented shaps, so that it can be applied to fracture behavior of materials to investigate the fracture process. Fractal curves have a characteristic that represents a self-similarity as an invariant based on the fractal dimension. This fractal geometry was applied to the crack growth of cementitious composites in order to correlate the fracture behavior to microstructures of cemposite composites. The purpose of this study was to find relationships between fractal dimensions and fracture energy. Fracture test was carried out in order to investigate the fracture behavior of plain and fiber reinforced cement composites. The load-CMOD curve and fracture energy of the beams were observed under the three point loading system. The crack profiles were obtained by the image processing system. Box counting method was used to determine the fractal dimension, D$_{f}$. It was known that the linear correlation exists between fractal dimension and fracture energy of the cement composites. The implications of the fractal nature for the crack growth behavior on the fracture energy, G$_{f}$ is appearent.ent.

Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk (손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교)

  • Kim, Kyung Ah;Na, Kyung Soo;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2017
  • Purpose: The purpose of this study was to compare volumetric modulated arc therapy(VMAT) with fixed-field intensity modulated radiation therapy(IMRT) using non-coplanar beam when the shape of target is irregular and the location is adjacent to organ at risk(OAR). Materials and Methods: The subjects of this study were a total of 6 patients who had radiation therapy for whole scalp(2 patients), partial scalp(2 patients), and whole ventricle(2 patients) by True Beam STX(Varian Medical Systems, USA). VMAT plans consisted of coplanar or non-coplanar arcs which can minimize the volume of OAR included in beamlets. All fixed-field IMRT plans consisted of non-coplanar beams using more than 2 angles of Couch. Results: The VMAT and IMRT plans were compared with regard to the maximum dose of both lens, both optic nerves, optic chiasm, and brain stem and the mean dose of both eyeballs and hippocampus. VMAT plans showed higher dose than ncIMRT plans at more than 6 of all OARs in every patient, and the ratio was from 1.1 times to 8.2 times. In case of total scalp and partial scalp, the volume of brain which received more than 20 Gy in the VMAT plans was 2 times larger than the volume in the ncIMRT plans. In case of whole ventricle, there was no significant difference. Target coverage was satisfied in both plans($PTV_{100%}=95%$). The maximum dose in target volume and required monitor unit(MU) of ncIMRT were higher than them of VMAT plans. Conclusion: Even though ncIMRT is less efficient than VMAT with regard to required MU and treatment time, the dose to OARs is much lower than VMAT and PTV Coverage is similar with VMAT. If the shape of target is irregular and location is adjacent to OAR, comparison VMAT plan with ncIMRT plan deserves to be considered.

  • PDF

Behavior of Reinforced Concrete Inclined Column-Beam Joints (철근콘크리트 경사기둥-보 접합부의 거동)

  • Kwon, Goo-Jung;Park, Jong-Wook;Yoon, Seok-Gwang;Kim, Tae-Jin;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.147-156
    • /
    • 2012
  • In recent years, many high-rise buildings have been constructed in irregular structural system with inclined columns, which may have effect on the structural behavior of beam-column joints. Since the external load leads to shear and flexural forces on the inclined columns in different way from those on the conventional vertical columns, failure mode, resistant strength, and ductility capacity of the inclined column-beam joints may be different than those of the perpendicular beam-column joints. In this study, six RC inclined beam-column joint specimens were tested. The main parameter of the specimens was the angle between axes of the column and beam (90, 67.5, and 45 degree). Test results indicated that the structural behavior of conventional perpendicular beam-column joint was different to that of the inclined beam-column joints, due to different loading conditions between inclined and perpendicular beam-column joints. Both upper and lower columns of perpendicular beam-column joints were subjected to compressive force, while the upper and lower columns of the inclined beam-column joints were subjected to tensile and compressive forces, respectively.