• 제목/요약/키워드: irradiation test

검색결과 689건 처리시간 0.032초

연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석 (Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition)

  • 김경수;윤재호
    • Current Photovoltaic Research
    • /
    • 제6권3호
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

계장핵연료 조사시험용 실튜브 레이저용접기술 (Laser Welding of Seal Tube for Instrumented Irradiation Fuel Test)

  • 김수성;이철용;김웅기;박근일;고진현;서준석
    • Journal of Welding and Joining
    • /
    • 제23권6호
    • /
    • pp.43-48
    • /
    • 2005
  • This work was carried out to obtain sound welds and to select a most suitable binary metal joint among three different dissimilar binary metal combinations such as Zr-4/Ta, Mo/Ta and Ti/Ta(seal tube/sensor sheath) joints fur the instrumented nuclear fuel irradiation test. To do this, Taguchi experimental method was employed to optimize the experimental data. In addition, metallography, micro-focus x-ray radiography and hardness test were conducted to examine the welds. From the weld bead appearance, penetration depth and bead width as well as weld defects standpoint, Zr-4/Ta joint is suggested for the circumferential joining between a seal tube and a sensor sheath. The optimized welding parameters based on Zr-4/Ta joint are suggested as well.

흰쥐 정소의 방사선 조사에 따른 정자변화의 영상처리에 의한 정량분석 (The quantitative analysis by the image processing of sperm changes according to the radiation irradiation of white rat testicle)

  • 나수경;김성인;이언석
    • 디지털융복합연구
    • /
    • 제12권6호
    • /
    • pp.433-438
    • /
    • 2014
  • 본 연구는 흰쥐의 정소에 방사선을 조사하였을 때 시간이 경과함에 따라 나타나는 정소세포 및 정자의 변화를 현미경학적으로 얻은 영상을 기초로 영상처리에 의한 정량분석을 통하여 정자의 변화에 대한 결과를 정량화함으로써 더 정확하고 객관적인 결과를 얻고자 하는데 그 목적을 두고 있다. 연구에는 8주 수령의 흰쥐를 대상으로 하였으며, 6 MV의 X선을 1회 2 Gy를 전신 조사하였다. 총 30 마리의 흰쥐를 대상으로 방사선을 조사하지 않은 정상대조군과 실험군을 조사 즉시, 조사 2시간, 4시간, 8시간, 24시간 후에 각 실험군 마다 5마리의 정소를 각각 적출하였다. 적출 후 Periodic acid Schiff 염색을 시행하여 정상대조군과 실험군에서의 정소세포와 정자의 상태를 관찰하였다. 방사선조사 후 24시간까지, 정소세포수와 정자수가 점차 감소하는 것을 정성적 및 정량적으로 유의함을 확인하였다.

방사선 전신조사 환자의 말초혈액 검사를 통한 급성장애 지표개발에 관한 연구 (Study on Development of Acute Index Through Peripheral Blood Test in Total Body Irradiation Patients)

  • 박영환
    • 대한방사선치료학회지
    • /
    • 제13권1호
    • /
    • pp.91-103
    • /
    • 2001
  • 골수이식 수술을 위해 10MV X-ray로 전신 방사선 치료 환자 중 18명을 무작위 추출하여 조사한 후 25일간 말초혈액의(백혈구, Seg. neutrophil, 임파구, 적혈구, 헤모글로빈, 헤마토치, GOT, GPT 등) 수치변화를 대조군 32명과 본인의 방사선 조사전과 비교하여, 고선량의 방사선 피폭이 인체의 말초혈액에 미치는 영향을 평가하였다. 말초혈액 변화 중 백혈구는 방사선 치료 전 검사 $2.51{\times}103{\pm}1.29{\times}103/mm^3$에 비해 $0.22{\times}103{\pm}0.19{\times}103/mm^3$로 최저 $8.63\%$을 나타냈고, 대조군 $7.17{\times}103/mm^3{\pm}1.46{\times}103/mm^3$에 비해서는 $6.35\%$로 낮은 수준을 나타내어 통계적인 유의성이 있었다(P<0.01, r2=0.9151). 백혈구 형태학적 검사 중 Seg. neutrophil은 조사 전 $69.00{\pm}25.60\%$에 비해 $14.17{\pm}21.60\%$로 최저 $20.53\%$수준으로 낮았고, 대조군 $58.09{\pm}7.62\%$에 비해서는 $24.39\%$ 수준으로 감소하였다(P<0.05, r2=0.6316). 임파구 수는 조사 전 $20.29408{\pm}21.15\%$에서 $79.91{\pm}27.30\%$로 최고 3.94배로 높게 나타났고, 대조군 $33.46{\pm}6.79\%$에 비해 2.39배 높게 나타났다(P<0.05, r2=0.7337). 적혈구 수의 변화는 조사 전 $3.18{\times}106{\pm}0.41{\times}106/mm^3$과 대조군 $4.66{\times}106{\pm}0.43{\times}106/mm^3$에 대해 낮은 수준을 나타냈으나 통계적인 유의성은 없었다(P>0.05). 헤모글로빈과 헤마토치의 수치도 조사전과 대조군에 대한 비교에서도 낮게 나타났으나, 모두 통계적인 유의성은 없었다. 그러나 조직학적 검사인 GOT와 GPT값은 조사전과 대조군에 비해 모두 통계적인 유의성이 있었다(P<0.05). 이와 같이 고선량의 방사선 전신 조사 후 말초 혈액 중 백혈구의 수치가 일정 기간에 급격 히 감소하였고, 백혈구 형태학적 검사중 Seg. neutriphil과 임파구수치도 현저하게 감소하였다. 따라서 본 연구 결과로 인체에 고선량의 방사선에 피폭되었을 때, 일반적인 말초혈액 검사를 이용하여 방사선 급성장해 유발 가능자를 1차 적으로 선별 할 수 있는 지표 개발 가능성을 제시하였다고 사료된다.

  • PDF

방사선환경에서 ACP 주요부품의 신뢰도 평가 (Reliability Evaluation of ACP Component under a Radiation Environment)

  • 이효직;윤광호;임광묵;박병석;윤지섭
    • 방사성폐기물학회지
    • /
    • 제5권4호
    • /
    • pp.309-322
    • /
    • 2007
  • 이 논문은 사용후핵연료 차세대관리공정(ACP)에 사용되는 주요부품에 대한 방사선영향에 대하여 다룬다. 평가대상 부품으로는 중요도가 높은 것들 중에서 선택하였는데, AC 서보모터, 포텐쇼미터, 열전대, 가속도계, CCD 카메라를 그 대상으로 하였다. AC 서보모터의 경우 ACP 핫셀 내 조작기에 여러개가 사용되고 있고, 공정장치의 일부에 사용되고 있다. 포텐쇼미터는 조작기 관절의 절대 각도를 측정하기 위해 사용된다. 열전대는 금속전환장치 등의 반응기 온도 측정을 위해 사용된다. 가속도계는 탈피복시 발생하는 이상을 사전에 감지하기 위한 용도로 탈피복장치에 부착되어 있고, CCD 카메라는 조작기와 함께 공정 휴지기간에 영상 In-situ 이상감시를 하기 위한 용도로 사용된다. 다양한 방사선 중 감마선은 전기, 전자 및 로봇 부품에 가장 치명적이라고 알려져 있으므로 본 연구에서는 Co-60선원을 사용하는 감마조사시설을 이용해 방사선 영향을 평가하였다. 방사선조사결과 CCD 카메라를 제외한 다른 부품들은 방사선에 매우 강인한 특성을 보였다. 누적조사선량에 대한 각 대상 부품의 고유한 특성변화 데이터를 얻었고, 대상 부품의 성능을 보장할 수 있는 기준인 손상분기점에 대한 평가 자료를 얻을 수 있었다

  • PDF

MECHANICAL AND IRRADIATION PROPERTIES OF ZIRCONIUM ALLOYS IRRADIATED IN HANARO

  • Kwon, Oh-Hyun;Eom, Kyong-Bo;Kim, Jae-Ik;Suh, Jung-Min;Jeon, Kyeong-Lak
    • Nuclear Engineering and Technology
    • /
    • 제43권1호
    • /
    • pp.19-24
    • /
    • 2011
  • These experimental studies are carried out to build a database for analyzing fuel performance in nuclear power plants. In particular, this study focuses on the mechanical and irradiation properties of three kinds of zirconium alloy (Alloy A, Alloy B and Alloy C) irradiated in the HANARO (High-flux Advanced Neutron Application Reactor), one of the leading multipurpose research reactors in the world. Yield strength and ultimate tensile strength were measured to determine the mechanical properties before and after irradiation, while irradiation growth was measured for the irradiation properties. The samples for irradiation testing are classified by texture. For the irradiation condition, all samples were wrapped into the capsule (07M-13N) and irradiated in the HANARO for about 100 days (E > 1.0 MeV, $1.1{\times}10^{21}\;n/cm^2$). These tests and results indicate that the mechanical properties of zirconium alloys are similar whether unirradiated or irradiated. Alloy B has shown the highest yield strength and tensile strength properties compared to other alloys in irradiated condition. Even though each of the zirconium alloys has a different alloying content, this content does not seem to affect the mechanical properties under an unirradiated condition and low fluence. And all the alloys have shown the tendency to increase in yield strength and ultimate tensile strength. Transverse specimens of each of the zirconium alloys have a slightly lower irradiation growth tendency than longitudinal specimens. However, for clear analysis of texture effects, further testing under higher irradiation conditions is needed.

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • 제20권4호
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.

Radiation effect on peri-implant tissue after implantation

  • Kweon, Hyeog-Sin;Song, Kwang-Yeob
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.291-309
    • /
    • 2000
  • Statement of problem. There were several studies on the effects of irradiation to peri-implant bone tissue. However, no clear biological effect of irradiation on peri-implant bone tissue was reported yet. Purpose. This study compared the effect of irradiation on the surrounding tissue of a HA-coated implant fixture with controls. Material and methods. 6 Steri-Oss implants were implanted into the femur of 6 mongrels. The implanted dogs were divided into three groups and received irradiation. After 1 month, 2months and 4 months healing period, the histologic examination and mobility test and digital radiographic imaging analyses were performed to compare the control and experimental group respectively. Results. The irradiated group showed slower healing than control group in light microscopic observations. The mobility test demonstrated significant less number (Periotest) in control group than that of irradiated groups. The digital radiographic imaging analysis showed that the bone density of irradiated group was higher than control group. Conclusion. Generally, control group showed favorable biological response and less mobility than irradiated group. The conflict result of bone density value were measured by the digital radiographic imaging analysis. The digital radiographic imaging analysis needs more research in future.

  • PDF

바코드 라벨의 방사선 조사시험 (Irradiation Test of Bar Code Label)

  • 배상민;이강무;손종식;홍권표;고병령
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.544-548
    • /
    • 2003
  • 바코드 라벨의 방사선 조사 시험은 방사성폐기물 용기에 부착할 바코드 라벨의 방사선 환경 하에서의 영향을 판단하기 위하여 수행하였다. 중$\cdot$저준위 방사성 폐기물은 원자력법에 의하면 총 방사능량이 4,000 Bq/g 미만을 말한다. 방사성 폐기물 용기의 외부에 부착할 바코드 라벨이 받게 되는 방사선 조사선량은 MCNP-4b Computer Code에 의하여 계산하였다. Co-60과 Cs-137 핵종들은 총 방사능에 50%씩 기여한다고 가정하였다. 용기와 바코드 라벨의 제원에 의하여 실제의 최종 방사선 조사선량을 계산하였다. 바코드 판독기를 이용하여 바코드 라벨의 인식률과 외관점검을 수행한 결과 코팅된 바코드 라벨은 중$\cdot$저준위 방사성 폐기물 용기에 사용하기에 적합하였다.

  • PDF