• Title/Summary/Keyword: irradiation mode

Search Result 115, Processing Time 0.023 seconds

Effects of Ionizing Radiation on Development of Invertase Activity, Nucleic Acids, and Respiratory Activity in Aging Potato Tuber Slices (방사선(放射線) 조사(照射)가 숙성(熟成)시킨 감자 괴경(塊莖) 박편(薄片)에서 Invertase, 핵산(核酸) 및 호흡작용(呼吸作用)의 발달(發達)에 미치는 영향(影響))

  • Lee, Mie-Soon;Kim, Hong-Lyour;Hong, Yung-Pyo
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.157-162
    • /
    • 1973
  • Mode of action study of irradiation was performed with potato tuber slices, $1mm{\times}1.5cm,$ aged on moist filter paper under aseptic technique. The time courses of invertase activity, nucleic acids and respiratory activity were determined, and sensitivities of these three processes to ionizing radiation were measured. None of those processes was severely inhibited by the dosage suppressing cell division. The result of $^3H-thymidine$ incorporation suggests that the reaction site of ionizing radiation might be existent during mitosis or $G_2$ period.

  • PDF

Coherent motion of fluxons in stacked intrinsic Josephson junctions of $Bi_2$$Sr_2$Ca$Cu_2$$O_{8+x}$ single crystals ($Bi_2Sr_2CaCu_2O_{8+x}$ 단결정 선천성 조셉슨 접합에서의 플럭손 결맞음 운동)

  • Doh, Yong-Joo;Chang, Hyun-Sik;Chang, Dong-In;Lee, Hu-Jong;Kim, Jinhee;Kim, Kyu-Tae;Lee, Woo;Choy, Jin-Ho
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.28-30
    • /
    • 2001
  • We studied the flux-flow current-voltage characteristics of microwave-generated fluxons formed in serially stacked intrinsic Josephson junctions fabricated on$ HgI_2$-intercalated $Bi_2$$Sr_2$$CaCu_2$O/8+x/(Bi2212) single crystals. With increasing the irradiation power of 73$\square$76 GHz microwave, the supercurrent branch became resistive and split into multiple sub -branches. Each sub-branch represented a specific mode of collective motion of Josephson fluxons. We also observed similar branch splitting In a mesa prepared on an underdoped Bi2212 single crystal in a static magnetic field.

  • PDF

Design and Analysis of 3-Section Hybrid Control Method for Solar Array Simulator (태양광패널 모사장치를 위한 3-구역 하이브리드 제어기의 설계 및 분석)

  • Seo, Young-Tae;Wellawatta, Thusitha;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.47-58
    • /
    • 2018
  • A solar array simulator (SAS) consists of an engine that generates a setpoint according to panel characteristics, a power stage that provides the actual output, and a controller. Particularly, if the control method is not suitable due to the nonlinearity of the solar panel output curve depending on the irradiation amount and the temperature, and the variation of the curve factor depending on the various panel materials, then the panel simulation function cannot be performed properly. Current and voltage mode controls are usually used for the conventional control method. However, these control methods deteriorate the control performance near the maximum power point; thus, a hybrid control method using two or more controllers has been investigated. In this study, we analyze the hybrid control method using three controllers divided into different areas. The design equation of the controller is derived based on the small signal modeling of each controller, and the simulation performance of the solar array simulator verifies its stability and response speed.

Modal Analysis and Testing for a Middle Spacer Grid of a Nuclear Fuel Rod (핵 연료봉 중간 지지격자의 모달 해석 및 실험)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1948-1952
    • /
    • 2012
  • The paper presents modal testing and analysis in order to obtain the dynamic characteristics of a middle spacer grids of a nuclear fuel rod. A spacer grid is one of the important structural elements supporting nuclear fuel rods. Such a fuel rod can be oscillated by its thermal expansion, neutron irradiation and etc. due to cooling water flow under the operation of a nuclear power plant. When the fuel rod vibrates, fretting wear due to repeated friction motion between the fuel rods and spacer grids can be occurred, and so the fuel rod is damaged. In this paper, through modal analysis and testing, natural frequencies and modes of a middle spacer grid were calculated, and the following conclusions were obtained. Firstly the numerical first-seven natural frequencies for spacer grids of a fuel rod having complicated structures have a small difference within 3.8% with experimental natural frequencies, and so the suitability of simulation results was verified. Secondly, experimental mode shapes for a middle spacer grid of a nuclear fuel rod were verified by obtaining lower non-diagonal terms through MAC(Modal Assurance Criteria), and were confirmed by the simulation modes.

Electro-Optical Characteristics of the UV Aligned LCD Cell (UV 배향된 액정셀에서의 전기광학 특성)

  • Lee, Byung-Soon;Lee, Ho-Young
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.223-226
    • /
    • 2013
  • In this study, we investigated the electro-optical(EO) characteristic of fringe-field switching(FFS) mode cell by the two kinds of ultraviolet(UV) alignment method on the organic thin film(polyimide: PI). The suitable organic layersfor FFS cell and the aligning capabilities of nematic liquid crystal(NLC) using the in-situ photoalignment method were studied Disclination is observed after conventional photoalignment method for 1h, and in-situ photoalignment method for 1h. Monodomain alignment of the NLC can be observed via in-situ photoalignment method for 2h and 3h. It is considered that NLC alignment is due to photo-depolymerization of the polymer with oblique non-polarized UV irradiation on PI surface. An unstable V-T curve of UV-aligned FFS-LCD with conventional photoalignment method can be achieved. However, a stable V-T curve of UV-aligned FFS-LCD with in-situ photoalignment method(1h), and V-T curve of UV-aligned FFS-LCD with in-situphotoalignment method was much stable comparing with that of other UV-aligned FFS-LCD's. As a result, more stable EO performanceof UV-aligned FFS-LCD with in-situphotoalignment method for 3h is obtained than that of the other UV-aligned FFS-LCD's.

Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target

  • Lim, Soobin;Kim, Donghwan;Kang, Jin-Goo;Dang, Jeong-Jeung;Lee, Pilsoo;Kim, Geehyun;Chung, Kyoung-Jae;Hwang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.437-441
    • /
    • 2022
  • In this study, we developed a neutron time-of-flight (nTOF) measurement system for a 1.7-MV tandem proton accelerator with a target covered with 300-nm-thick lithium (Li) layer. With implementation of beam chopping module after its ion source, the accelerator is configured to operate in pulsed-beam mode with a pulse width <50 ns at 20-kHz repetition rate. This enables the gamma flash-type nTOF measurement system to identify the neutron generated with 3-MeV proton beam energy. The nTOF system consists of a 30" cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. The nTOF system successfully measured the generated neutron energy at irradiated proton energies of 2.6 and 3.0 MeV with an average energy resolution of 15%.

Development of a prototype TL/OSL reader for on-site use in a large-scale radiological accident

  • Hyoungtaek Kim;Chang-Young Park;Sang In Kim;Min Chae Kim;Jungil Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2113-2119
    • /
    • 2024
  • This study presents the development and characterization of a prototype TL/OSL reader for the retrospective dose assessment of individuals in radiological emergencies. The reader is portable, semi-automatic, and capable of accurate measurements. The dimension of the reader is 25 × 25 × 37 cm3 and the weight is about 15 kg. The reader consists of a sample moving stage, a heating module, an optical stimulation module, a detection module, a data acquisition (DAQ) unit, a nitrogen gas control module, and a PC with a GUI program. The reader has three measurement modes: TL, CW_OSL, and custom mode. The reader was characterized using commercial thermal luminescence dosimeters (TLD, LiF:Mg,Cu,Si) and optically stimulated dosimeters (OSLD, Al2O3:C), as well as fortuitous materials, such as display glasses and resistors of mobile phone. The results showed that the reader is capable of measuring signals with a detection limit of up to 0.02 mGy using a commercial dosimeter. In the dose recovery test using fortuitous materials, the reconstructed doses obtained three days post-irradiation closely aligned with the initially administered doses. As a result, this study suggests that the developed TL/OSL reader is a promising instrument for emergency dose assessment at accident sites.

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Intrapulpal Temperature Change during Cavity Preparation on the Enamel and Dentin with an Er:YAG Laser (Er:YAG 레이저를 이용한 법랑질 및 상아질 와동 형성시의 치수내 온도변화)

  • Yang, Hee-Young;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • The purpose of our study was to investigate whether the intrapulpal temperature during cavity preparation of enamel or dentin with Er:YAG laser still remained in range of safety for dental pulp protection when combined with appropriate water flow rate. The effect of different pulse repetition rates at the same pulse energy during ablation was evaluated as well. Caries-free, restoration-free extracted human molar teeth were prepared for the specimen and divided two experimental groups of enamel and dentin. Each group comprised 5 specimens and each of tooth specimens were embedded into a resin block each and measuring probe was placed on the irradiated pulpal walls. For experiments of dentin ablation, enamel layers were prepared to produce dentin specimen with a same dentin thickness of 2 mm. A pulse energy of Er:YAG laser was set to 300 mJ and three different pulse repetition rates of 20 Hz, 15 Hz and 10 Hz were employed. Laser beam was delivered with 3 seconds and less per application over enamel and dentin surfaces constant sized by $3\;mm{\times}2\;mm$ and water spray added during irradiation was a rate of 1.6 ml/min. Temperature change induced by Er:YAG laser irradiation was monitored and recorded While enamel was ablated, there was no significant difference of temperature related to pulse repetition rates(p=0.358) and temperature change at any pulse repetition rate was negligible. Significant statistical difference in temperature changes during cavity preparation in dentin existed among three different pulse groups(p=0.001). While temperature rise was noticeable when the dentinal wall was perforated, actual change of temperature due to Er:YAG laser irradiation was not enough to compromise safety of dental pulp when irradiation was conjugated with appropriate water spray. Conclusively, it can be said that cavity preparation on enamel or dentin with an Er:YAG laser is performed safely without pulp damage if appropriate volume of water is sprayed properly over the irradiated site.

Significance of Apoptotic Cell Death after $\gamma-Irradiation$ (방사선 조사에 의한 세포사에 있어서 세포고사의 의미)

  • Wu H.G.;Kim I.H.
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.252-258
    • /
    • 2001
  • Purpose : The objectives of this study are to investigate the significance of apoptotic death compared to total cell death after $\gamma-ray$ irradiation in human H&N cancer cell lines and to find out correlation between apoptosis and radiation sensitivity. Materials and method : Head and neck cancer cell lines (PCI-1, PCI-13, and SNU-1066), leukemia cell line (CCRF-CEM), and fibroblast cell line (LM217) as a normal control were used for this study. Cells were irradiated using Cs-137 animal experiment irradiator. Total cell death was measured by clonogenic assay. Annexin-V staining was used to detect the fraction of apoptotic death. Results : Surviving fraction at 2 Gy (SF2) were 0.741, 0.544, 0.313, 0.302, and 0.100 for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217 cell lines, respectively. Apoptosis was detected in all cell lines. Apoptotic index reached peak value at 72 hours after irradiation in head and neck cancer cell lines, and that was at 24 hours in CCRF-CEM and LM217. Total cell death increased exponentially with increasing radiation dose from 0 Gy to 8 Gy, but the change was minimal in apoptotic index. Apoptotic fractions at 2 Gy were $46\%,\;48\%,\;46\%,\;24\%,\;and\;19\%$ and at 6 Gy were $20\%,\;33\%,\;35\%,\;17\%,\;and\;20\%$ for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217, respectively. The radioresistant cell lines showed more higher apoptotic fraction at 2 Gy, but there was not such correlation at 6 Gy. Conclusion : All cell lines used in this study showed apoptosis after irradiation, but time course of apoptosis was different from that of leukemia cell line and normal fibroblast cell line. Reproductive cell death was more important mode of cell death than apoptotic death in all cell lines used in this study. But there was correlation between apoptotic fraction and radiation sensitivity at 2 Gy.

  • PDF