• Title/Summary/Keyword: irradiation mode

Search Result 114, Processing Time 0.028 seconds

Demulsification of Oil-Water Emulsions Using Different Microwave Irradiation Mode (마이크로파 조사 방식에 의한 Oil-Water 에멀젼 분리)

  • Hong, Joo-Hee;Kim, Byoung-Sik;Kim, Dok-Chan
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.653-659
    • /
    • 2005
  • When emulsion is irradiated by a microwave, the energy absorbed by the emulsion is proportional to irradiation time. In case of a long exposure, the temperature of emulsion rises, its viscosity decrease, and subsequently increase the rate of demulsification. In this work, in order to improve demulsification rate, the studies on demusification and the Sauter mean diameter ($D_{32}$) for each microwaved emulsion with different irradiation mode(continuous, pulsative, and periodical irradiation) have been carried out. When the 30% W/O emulsion (sample #1) was irradiated for 600 sec and settled for 24 h, oil recovery rates from continuous, pulsative, and periodical microwave irradiation were 60.0%, 62.3%, and 96.2%, and the amounts of separated water were 26.5%, 35.0%, and 93.9%, respectively. Also, the Sauter mean diameters ($D_{32}$) were $47.183{\mu}m$, $111.547{\mu}m$, and $220.476{\mu}m$, respectively.

The effect of irradiation mode on degree of cure, shrinkage and microleakage of composite resin restroation.

  • Park, Jong-Jin;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.555-555
    • /
    • 2001
  • The aims of this study are (1) to investigate the relation of irradiation mode, polymerzition shrinkage and degree of cure of composite resin and (2) it effect on microliakage of calss V restorations. VIP(BISCO Dental Products, Schaumburg, IL, USA) and Optilux 501(Demetron/Kerr, Danbury, CT, USA) curing lights were used for curing Z-250 composite resin following irradiation mode: VIP 200㎽, VIP 400㎽, VIP 600㎽, pulse-delay(200㎽ 3sec, 5min wait, 600㎽ 30sec), Optilux C mode, Optilux R mode.(omitted)

  • PDF

The effect of irradiation mode on degree of cure, shrinkage and microleakage of composite resin restoration.

  • Park, Jong-Jin;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.558.2-558
    • /
    • 2001
  • The aims of this study are (1) to investigate the relation of irradiation mode, polymerization shrinkage and degree of cure of composite resin and(2) it effect on micorleakage of class V restorations. VIP(BISCO Dental Products, Schaumburg, IL, USA) and Optilux 501 (Demetron/Kerr, Danbury, CT, USA) curing lights were used for curing Z-250 composite resin following irradiation mode: VIP 200㎽d, VIP 400㎽, VIP 600㎽, pulse-delay(200㎽ 3sec, 5min wait, 600㎽ 30sec), Optilux R mode.(omitted)

  • PDF

Tribological Characteristics of Carbon Fiber Reinforced Plastics by Surface modification (탄소섬유복합재의 표면개질에 따른 트라이볼로지 특성에 관한 연구)

  • 전승흥;양준호;오성모;이봉구
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.29-36
    • /
    • 2000
  • This investigation has been studied about friction and wear properties which were important problem, when carbon fiber reinforced plastic(CFRP) was used practically. Unidirection carbon fiber reinforced composites was fabricated with epoxy resin matrix and carbon fiber as a reinforced, and its surface was modified by the ion-assisted reaction. And then we tested the their friction and wear properties according to the ion-irradiation. when the amount of ion-irradiation was 1${\times}$10l6$\^$16/ ions/$\textrm{cm}^2$, the friction coefficient values were about 0.1, where as, the friction coefficient values of non-treatment composites were about 0.16. The former was the stablest in wear mode. We know that ion-irradiation was not proportioned to the friction coefficient, so we found the optimal conditions of the friction and wear according to the ion-irradiation.

  • PDF

A Study on the Friction and Wear Characteristics of Carbon Fiber Reinforced Plastics by Surface Modification (표면개질에 따른 탄소섬유복합재의 마찰마모 특성에 관한 연구)

  • O, Seong-Mo;Lee, Bong-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.122-128
    • /
    • 2001
  • The objective of the present study was to investigate the characteristics of the friction and wear according to the amount of ion-irradiation for the carbon fiber reinforced plastic(CFRP). Unidirectional carbon fiber reinforced composites were fabricated with epoxy resin as a matrix and carbon fiber as a reinforcement, and its surface was modified by the ion-assisted reaction. When the amount of ion-irradiation was $1{\times}10^{16}$ ions/$cm^2$, the friction coefficients of composites were about 0.1 and the wear mode was stable, whereas, the friction coefficient of non-treatment composites were about 0.16 and the wear mode was very unstable. But if the amount of ion-irradiation was $5{\times}10^{16}$ ions/$cm^2$, the friction coefficients were higher rather than that of $1{\times}10^{16}$ ions/$cm^2$. Consequently, the amount of ion-irradiation was not in proportion to the friction coefficients, and it was conformed that the optimal conditions would exist between broth of them.

  • PDF

Tribological Characteristics of Surface Modification by Carbon Fiber Reinforced Plastics (탄소섬유복합재의 표면개질에 따른 트라이볼로지 특성에 관한 연구)

  • Kim, Jong-Hee;Jeon, Seung-Hong;Lee, Bong-Goo;Oh, Seong-Mo
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.61-67
    • /
    • 2002
  • The objective of the present study was to investigate the characteristics of the friction and wear according to the amount of ion-irradiation for the carbon fiber reinforced plastic (CFRP). Unidirectional carbon fiber reinforced composites were fabricated with epoxy resin as a matrix and carbon fiber as a reinforcement, and its surface was modified by the ion-assisted reaction. When the amount of ion-irradiation was $1{\times}10^{16}$ $ions/cm^{2}$. the friction coefficients of composites were about 0.1 and the wear mode was stable. whereas, the friction coefficient of non-treatment composites were about 0.16 and the wear mode was very unstable. But if the amount of ion-irradiation was $5{\times}10^{16}$ $ions/cm^{2}$, the friction coefficients were higher rather than that of $1{\times}10^{16}$ $ions/cm^{2}$ Consequently. the amount of ion-irradiation was not in proportion to the friction coefficients, and it was conformed that the optimal conditions would exist between both of them.

Tribological Characteristics of Carbon Fiber Reinforced Plastics Prepared by Ion-Assisted Reaction (이온도움반응법에 의한 탄소섬유복합재의 트라이볼로지 특성연구)

  • 오성모;김정기;이봉구
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.103-108
    • /
    • 2004
  • Carbon fiber reinforced composites(CFRP) were fabricated with phenolic resin matrix by hot press molding, and its surface was modified by the ion-assisted reaction process. When we tested the friction coefficient and wear rate variation and observed the effect of fibers with respect to friction and wear characteristics, the amount of pitch based carbon fiber was 45wt% and the average friction coefficient was the lowest at 0.12. When the amount of ion-irradiation was $1\times10^{l6}ions/cm^2$, the friction coefficient of the composites was about 0.12 and the wear mode was stable, whereas, the friction coefficient of the non-treated composites was about 0.16 and the wear mode was very unstable. But if the amount of ion-irradiation was $5\times10^{l6}ions/cm^2$$1\times10^{l6}ions/cm^2$ion-irradiation case.

Quantitative Evaluation on Laser Performance for Endovenous Photocoagulation (레이저를 이용한 하지정맥류 치료의 정량화 연구)

  • Ahn, Minwoo;Nguyen, Van Phuc;Oh, Junghwan;Kang, Hyun Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.62-67
    • /
    • 2014
  • The purpose of the study was to identify the effect of laser parameters on photocoagulation to maximize safety and efficacy during varicose vein treatment. CW and pulsed modes at 1470 nm were initially compared as a function of power on bovine liver tissue. In the pulsed mode, various parameters including repetition rate, duty cycle, and irradiation time were compared to evaluate tissue response during thermal treatment. The results demonstrated that CW and pulsed modes yielded almost similar coagulation development possibly due to shorter irradiation time of 5 sec. Regardless of laser mode, both repetition rate and duty cycle presented constant coagulation rate whereas longer irradiation time facilitated coagulation process.

Development of LED Module for Tooth Care with Effect of Promoting Scar Treatment and Analysis of Optical Properties (흉터 치료 촉진 효과를 갖는 치아 케어용 LED 모듈 개발과 광학적특성 분석)

  • Yoo, Kyun-Man;Son, Jeong-Hueon;Jo, Hyun-Min;Kang, So-Hi;Kang, Seong-Soo;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.701-708
    • /
    • 2020
  • In this paper, we analyzed the optical properties of the LED module for dental care, which has the effect of promoting cell regeneration and scar treatment. The LED module is a U-shaped module suitable for the shape of teeth. It is manufactured with an LED module (632 nm) and an LED module (632 nm + 870 nm), analyzes the results of optical properties, sets the irradiation distance, irradiation time, and is effective in healing skin wounds. Evaluation was conducted. It was tested in 6 test groups according to the light irradiation conditions, and light was irradiated to the scar site every other day for 7 days, 1 day and 3 days. As a result, it was confirmed that the effect of scar treatment was the highest when the combined wavelength of 632 nm + 870 nm was irradiated in pulse mode than when the single wavelength was irradiated and the composite wavelength was continuously irradiated. In group C group irradiated with PW Mode: pulse mode (period 36 ms, pulse width 35 ms) using a composite wavelength with LED module (632 nm + 870 nm) than group A without light irradiation, the length of scar reduction was 19 %, the area of the scar was further reduced by 10%, and it was confirmed that it is effective in treating scars in the wound area.

Proton induced Effects on Commercial Single-mode Optical Fibers (상용 단일모드 광섬유의 양성자 영향)

  • Kim, Jong-yeol;Kim, Young-woong;Ryu, Guk-been;Hwang, Young-gwan;Lee, Min-Woong;Song, Keun-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.623-625
    • /
    • 2022
  • In this paper, the proton induced attenuation characteristics were evaluated for 5 types of commercial single-mode optical fibers using a proton accelerator. The proton beam used in the irradiation test has a high energy of 100 MeV class, and the test was performed by setting the uniformity of the beam irradiation area to 10% or less. According to the type of optical fiber (internal material, impurities), the radiation induced attenuation by the proton irradiation showed a noticeable difference.

  • PDF