• 제목/요약/키워드: iron-core

검색결과 434건 처리시간 0.026초

수백 kV급 공심형 펄스 변압기 개발 (Development of several hundred kV Air Core pulse transformer)

  • 김성철;박성수;김상희;허훈;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2132-2135
    • /
    • 2005
  • Cylindrical type air core pulse transformers capable of passing high voltage and energy pulse waveforms with high efficiency and low distortion require a much more delicate design balance of physical dimensions and electrical parameters than iron or ferrite core units. The structure of an air core high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent breakdown between transformer windings. Since the thickness of the windings in spiral type is on the order of sub-millimeter, field enhancement at the edge of the windings is very high. It is, therefore, important to find proper electrical insulation Parameter to make the system compact. Several shapes of the winding are considered for air core pulse transformer development. In this paper, we are described design procedure, parameters measure and experiment results of air core type HV pulse transformer.

  • PDF

반경방향 착자형과 Halbach 배열형 영구자석 회전자를 갖는 고속 슬롯리스 기기의 공극자속밀도 특성 비교 (Comparison on the Airgap Flux Density of High-Speed Slotless Machines with Radial Magnetization and Halbach Array PM Rotor)

  • 장석명;정상섭;류동완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권7호
    • /
    • pp.315-322
    • /
    • 2001
  • High speed brushless permanent magnet(PM) machines need a key technology to minimize the iron core losses in stator and the eddy current losses in the retained sleeve and magnets caused by slotting harmonics. Thus, slotless or iron-coreless brushless PM machines have been applied for a very high rotational speed and/or the ripple-free torque. Unfortunately, slotless or coreless PM machines have lower open-circuit field than slotted and/or iron-cored types, which cause to reduce power density. Fortunately, Halbach array can generate the strong magnetic field systems without additional magnetic materials. In this paper, the 4-pole Halbach array is applied to the high speed machine and is compared with the radial magnetized PM array in field system. The iron-/air-cored stator of PM machine is constructed with/without winding slots. Open circuit magnetic fields of each type are presented from the analytical method and finite element method. Consequently, it is confirmed that the Halbach array field system with slotless stator is more suitable to the high speed motor because it has high flux density, sinusoidal flux distribution than others.

  • PDF

6시그마 혁신활동을 통한 약품처리 최적화 (The Optimization of Chemical Treatments through the Six Sigma Innovation Activity)

  • 김태규;김홍철
    • 기술혁신학회지
    • /
    • 제7권3호
    • /
    • pp.641-656
    • /
    • 2004
  • L Company is producing the second sept pin, Shadow Mask which is the chief part of CRT in W, Monitor. Inside of the CRT pan, Shadow Mask leads the electronic beam to express the three primary colors; red, green, blue, and it is the core part to embody the colors. In the etching process, it produces this part with manufacturing by eroding the iron chloride. Even though the iron chloride is harmless to human body. it is necessary to diminish the amount of it on the view of preservation of environment. In addition, by studying the method of the dispossed liquid process, cutting down the manufacturing cost is a necessary task on the aspect of reconsideration of competitive business. This study shows the case that through the six sigma innovation activity, it reforms the following the former processing flow, and it reduces the amount of it by improving the efficiency of the iron chloride. By rationalization of the standard requirement cooperative company, it could cut down the manufacturing cost in the cooperative company, so it could promote the common profits.

  • PDF

EMTP-RV를 이용한 CT포화 모델링 (EMTP-RV Modeling of CT Saturation)

  • 강용철;최재선;정태영;강해권;장성일;김용균;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-11
    • /
    • 2008
  • A protection current transformer (CT) has been widely used for protection devices. When a fault occurs, a CT should provide the faithful reproduction of the primary fault current. However, a CT may saturates due to the magnitude of fault current, dc component primary time constant and the remanent flux of the iron core, and the secondary current of a CT is distorted. The distorted current can cause mal-operation or the operating time delay of a protection relay. This paper provides a modeling of CT saturation using EMTP-RV. The performance of the proposed CT saturation modeling was investigated under various fault conditions varying the fault distance, fault inception angle, and remanent flux of the iron core. The results indicate that the proposed EMTP-RV modeling can operate correctly, and the reasons for CT saturation are verified by EMTP-RV simulations.

  • PDF

화학기상응축공정으로 제조한 Fe(C) 나노캡슐의 합성 및 미세구조 (Synthesis and Microstructure of Fe(C) Nanocapsules by Chemical Vapor Condensation)

  • 이정한;김성덕;김진천;최철진;이찬규
    • 한국분말재료학회지
    • /
    • 제11권6호
    • /
    • pp.515-521
    • /
    • 2004
  • Fe(C) nanocapsules were prepared by the chemical vapor condensation(CVC) process using the pyrolysis of iron pentacarbonyl $(Fe(CO)_5)$. Their characterizations were studied by means of X-ray diffraction, X-ray photoelectron spectrometer and transmission electron microscopy. The long-chained Fe(C) nanocapsules hav-ing the mean size of under 70 nm could be obtained below $1100^{\circ}C$ in different gas flow rates. The particle size of the powders was increased with increasing decomposition temperature, but it was decreased with increasing CO gas flow rate. The Fe powders produced at $500^{\circ}C$ consisted of three layers of ${\alpha}$-Fe/$Fe_3C$/amorphous phases, but it had two phase core-shell structure which consited of $Fe_3C$ phase of core and graphite of shell at $1100^{\circ}C$.

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

인덕턴스 조정에 따른 자속구속형의 전류제한특성분석 (The Analysis of Characteristics of Flux-Lock Type SFCL with Adjustable Inductance Level in Current Limiting Operation)

  • 이나영;최효상;박형민;조용선;남긍현;임성훈;박충렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.157-158
    • /
    • 2005
  • Superconducting fault currents(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operation characteristics. We compared 21turn numbers with 42turn numbers according to wound turn numbers each the coil 2 under the additive polarity winding operation between coil 1 and coil 2. The three phase flux-lock type SFCL using an iron core differently operates general three phase resistive SFCLs. When a single line-to-ground fault occurred, the SFCL's three units were quenched after fault onset. We confirmed effective current limiting operation characteristics with adjustable inductance level.

  • PDF

자속 구속형 고온초전도 전류제한기의 동작특성 분석 (The Analysis of Operation Characteristics of Flux-Lock Type High-Tc Superconducting Fault Currents Limiter)

  • 박충렬;임성훈;박형민;이종화;고석철;최효상;한병성;현옥배;정동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1130-1132
    • /
    • 2004
  • In this paper, we investigated the operational characteristics of the fault current limiting in the The flux-lock type high-Tc superconducting fault current limiter. The flux-lock type high-Tc superconducting fault current limiter was consisted of primary and secondary copper coils that flux was locked on iron core and YBCO thin film. The operational characteristic of a flux-lock type SFCL dependent on winding direction of coil 1 and coil 2, and the number of turns of coil 1 and coil 2, inductances of the coils, saturation in iron core, the properties of superconducting element etc. In this cases, we investigated the fault currents limiting characteristics of the flux-lock type SFCL when winding direction of coil 1 and coil 2 was subtractive polarity winding.

  • PDF

철심 변류기의 2차 전류 보상 알고리즘의 실시간 구현 및 오차 분석 (Hardware implementation and error analysis of an algorithm for compensating the secondary current of iron-cored current transformers)

  • 강용철;김성수;박종근;강상희;김광호
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.490-500
    • /
    • 1996
  • The conventional method to deal with current transformer (CT) Saturation is over dimensioning of the core so that CTs can carry up to 20 times the rated current without exceeding 10% ratio correction. However, this not only reduces the sensitivity of relays as some errors may still be present in the secondary current when a severe fault occurs, but also increases the CT size. This paper presents an algorithm for compensating the distorted secondary current of iron-cored CTs under CT saturation using the magnetization (flux-current : .lambda.-i) curve and its performance is examined for fault currents encountered on a typical 345[kV] Korean transmission system, under a variety of different system and fault conditions. In addition, the results of hardware implementation of the algorithm using a TMS320C10 digital signal processor are also presented. The proposed algorithm can improve the sensitivity of relays to low level internal faults, maximize the stability of relays for external faults, and reduce the required CT core cross-section significantly. (author). refs., figs.

  • PDF

다자유도 구형 구동 모터의 와전류 손실 저감을 통한 효율 향상 연구 (Improve of Efficiency of Multi D.O.F Spherical Motor Through the Reduction of Eddy Current Loss)

  • 홍경표;김용;장익상;이호준;강동우;원성홍;이주
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.50-56
    • /
    • 2012
  • The Multi D.O.F spherical motor can drive rotating as well as tilting three degree of freedom with one motor. Existing three degree of freedom to drive with three motors that are connected by gears and belts, that will be too large size and big loss at gears and belts. So Reducing system size and improving efficient is using the Multi D.O.F spherical motor in three degree of freedom systems. For this reason, efficiency of Multi D.O.F spherical motor is one of the important performance indiccators. In this paper presented that how to improve the efficiency of the Multi D.O.F spherical motor. The fist of method is using the stator iron core's material with high permeability and resistivity for reducing the eddy current loss. However, it was the disadvatages of motor-making and economic. So author propose the resonable method of reducing the eddy current loss in the stator iron core. That is using the rotor with double-air gap.