• Title/Summary/Keyword: iron removal

Search Result 445, Processing Time 0.021 seconds

Recycling of Ti Turning Scraps for Production of Consumable Arc Electrode (아크용(用) 소모성(消耗性) 전극(電極) 제조(製造)를 위한 타이타늄 선삭(旋削) 스크랩의 재활용(再活用))

  • Oh, Jung-Min;Lim, Jae-Won
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.58-64
    • /
    • 2012
  • Ti button type ingots were prepared by recycling of Ti turning scraps using vacuum arc melting process for production of consumable arc electrode. The behavior of impurities such as Fe, W, O, and N in the Ti button ingots was investigated and the properties of the Ti button ingots were also evaluated. In the case of oxygen gaseous impurity, the oxygen layers on the surface of the Ti turning scraps were easily removed by the first vacuum arc melting. On the other hand, the solute oxygen in the Ti turning scraps was not removed by the next melting. In the case of Fe, major impurity in the Ti turning scraps, the removal degree in the final Ti button ingot refined by vacuum arc melting for 20 minutes was approximately 43 %, which is due to the vapor pressure difference between Ti and Fe. As a result, the Ti button ingots with ASTM grade 3 could be obtained by multiple vacuum arc melting from the Ti turning scraps. Therefore, it was confirmed that the preparation of consumable electrode for vacuum arc remelting could be possible by recycling of Ti turning scraps.

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Optimal Treatment of Molasses Wastewater Using UASB Process (UASB 공정에 의한 당밀폐수의 최적처리 방안)

  • Huh, Kwan-Yong;Jeong, Eui-Geun;Chung, Yoon-Jin;Yoo, Sang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.112-127
    • /
    • 1997
  • The purpose of this study is to get optimum operating factors of Upflow Anaerobic Sludge Blanket (UASB) reactor by introducing methods that make it to reduce inhibition possible in each process wastewater treatment. The used substrates, concentrated corn starch liquid (CSL) wastewater, modified starch, filtering and decoloring wastewater, ion refining wastewater, and mixed wastewater including modified starch and not including modified starch, are generated from molasses process. The seeding sludge is the digested sludge that had been applied to molasses wastewater. Batch test to reduce the inhibition factors that might be existed in each wastewater was examined. Based on the this test, the optimum operating factors according to alkalinity and pH variation was studied through the continuous test using three 5.5 L UASB reactor. The first reactor added $NaHCO_3$ to control alkalinity. The hydraulic retention time (HRT) reduced to 8 hours and the organic loading rate increased gradually. The second reactor changed the pH of influent from 7.0 to 6.0 using NaOH. The third reactor was operated without changes to compare the above two reactors. As the result, the inhibition in concentrated CSL wastewater was removed by adding iron (II). When trace metals were added to mixed wastewater not including modified starch, the digestability by gas production rate increased to more fifty percentage than mixed wastewater that was not adding the trace metals. The reason that the inhibition did not decreased in spite of adding trace metals and nutrients was influenced by high concentration generated during the acid fermentation. The UASB reactors using the mixed wastewater with the most effective performance were operated as 500 mg/L as $CaCO_3$ alkalinity and 6.0 pH at steady state, and at this time, the gas production rates were 283 and 311mL gas/g $COD_{added}$. The COD removal rates were 84.7 and 86.3%, respectively.

  • PDF

A Study on characteristics analysis of autotrophic denitrification microbial community using sulfur granule (황입자를 이용한 T. denitrificans에 의한 질소제거 최적화 연구)

  • Yoon, Su Chul;Joo, Jae-Young;Nam, Duck-Hyun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.259-265
    • /
    • 2008
  • Generally speaking, there are two widely used methods of Nitrogen removal from waste water: 1) nitrification using autotrophic microorganisms, and 2) denitrification using heterotrophic microorganisms. The C/N ratio is an important factor of the denitrification process. In this case, if methanol is added to increase the lacking organic matter, a high economic cost is incurred and methanol is left in the processed water. In an effort to fix these issues, autotrophic denitrification through the use of Hydrogen, Iron and Sulfur is being studied, and among those Sulfur is cheaper and carries out denitrification effectively, and therefore is being studied the most. In this study, after cultivating T. denitrificans, the presence of T. denitrificans was determined and the effectiveness of denitirification via T. denitrificans was studied. In order to find out about the inhibition of T. denitrificans from the loading of organic matter, this shows that the greater the loading of organic matter, the more the denitrification ability of T. denitrificans is hindered. In order to research the hindrance of T. denitrificans resulting from the loading of $NO_3{^-}-N$, these results show that concentrations less than 100mg/L per 100mL of gel volume do not hinder T. denitrificans. In order to research the optimization of denitrification resulting from T. denitrificans, three 500mL samples of Sulfur granules were prepared: 1) one with only T. denitrificans attached (Mode I), 2) one with both T. denitrificans and active sludge attached (Mode II), and 3) one with only active sludge attached (Mode III). The results showed that autotrophic denitrification using S from Mode I was the most active.

Removal of COD and T-N caused by ETA from Nuclear Power Plant Wastewater using 3D Packed Bed Bipolar Electrode System (3D 복극충진전기분해를 이용한 원전 ETA에 의해 유발된 폐수 내 COD 및 T-N 제거)

  • Kim, Han-Ki;Jeong, Joo-Young;Shin, Ja-Won;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.409-421
    • /
    • 2012
  • Ethanolamine (ETA) is mainly used to prevent corrosion of pipe in secondary cooling system of nuclear power plant. Condensed ETA in wastewater could increase COD and T-N when it was emitted to natural water system. Compared to conventional treatments, electrochemical oxidation process using packed bed bipolar electrodes was adopted to treat COD and T-N. According to arrangement of feeder electrode, single packed bed bipolar electrode reactor and multi-paired packed bed bipolar reactor were developed and conventional zero-valent iron (ZVI) was selected as conducting bipolar electrode. Bipolar electrodes were coordinated three-dimensionally in the reactor. The experimental results showed that COD and T-N was little removed in unit system at different pH condition (pH 8 and 11) on 100V. However, in multi-paired system that applied 600V, COD was eliminated 80.85% (anode-cathode-anode, A-C-A) and 85.11% (cathode-anode-cathode, C-A-C), respectively. T-N was also removed 96.88% (A-C-A) and 90.63% (C-A-C), simultaneously. Current efficiency was estimated both single and multi-paired system. At unit bipolar packed bed reactor, current efficiency was almost zero, however in multi-paired system, current efficiency was 300~500% at A-C-A and 250~350% at C-A-C. Current efficiency was over 100% hence it was confirmed that this system is more effective than conventional electrochemical oxidation system.

EPR Studies of the Active Sites of Carbon Monoxide Dehydrogenase from Clostridium thermoaceticum

  • Shin, Woonsup;Lindahl, Paul A.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.869-876
    • /
    • 1995
  • The active sites of the nickel and iron-containing enzyme, carbon monoxide dehydrogenase (CODH) from clostridium thermoaceticum were investigated using Electron Paramagnetic Resonance (EPR) technique. CODH exhibits several spectral features called NiFeC, $g_{ave}=1.82$, $g_{ave}=1.86$. FCII signals which are originated from different clusters in this enzyme. CODH is know to catalyze two different kinds of reactions - acetyl-CoA synthesis and CO oxidation. The acetyl-CoA synthesis activity can be followed by monitoring CO/acetyl-CoA exchange. The addition of 1,10-phenanthroline (phen) to CODH selectively destroyed the CO/acetyl-CoA exchange activity and eliminated the NiFeC signal completely. CO oxidation activity and other EPR signals were unaffected. Such behavior demonstrates that CODH has two distinct active sites and that the NiFe complex is only responsible for the CO/acctyl-CoA exchange activity. Phen caused the removal of only 30% of Ni in the NiFe complex ($0.3Ni/{\alpha}{\beta}$) as shown by the quantitative metal analysis. The phen-treated CODH could be reactivated fully by incubation In $Ni^{2+}$ solution. Radioactive $^{63}Ni^{2+}$ was used to quantitate the amount of the $Ni^{2+}$ incorporated into phen-treated enzyme and showed that the amount was the same as the removed by the phen treatment. i.e. $0.3Ni/{\alpha}{\beta}$. This indicates that only 30% of NiFe complexes are labile and responsible for the CO/acctyl-CoA exchange activity, the other 70% are non-labile and have no exchange activity. This is the first clear evidence that the NiFe complex is heterogencous and labile and non-labile Ni sites arc interacting differently with substrates and chelating agents like phen.

  • PDF

Analysis of Surface Contaminants and Removal Techniques on Three-story Stone Pagoda at the West of Gameunsaji Site (감은사지서삼층석탑의 표면오염물 분석과 제거기술)

  • Kim, Sa-Dug;Lee, Tae-Jong;Kim, Da-Ram;Han, Min-Su
    • Journal of Conservation Science
    • /
    • v.26 no.2
    • /
    • pp.203-211
    • /
    • 2010
  • Analytic research on the surface pollutant of the three storied-pagoda at the west of Gameunsaji site as well as studies of previous wet cleaning cases was undertaken in order to decide cleaning method for removing inorganic pollutants. The status of pollutant was examined by naked eye observation, SEM-EDS, XRD. Then it was compared and categorized through qualitive and quantitative analysis. The result showed that the surface pollutants consisted of iron compounds or sulfur compounds and it was crystallized in the form of circle, oval, needle, etc. Result, Low-pressure rotating vortex process cleaning, with which particular matters are sprayed in swirl, is considered to be the best method to remove the pollutants.

PARTITIONING RATIO OF DEPLETED URANIUM DURING A MELT DECONTAMINATION BY ARC MELTING

  • Min, Byeong-Yeon;Choi, Wang-Kyu;Oh, Won-Zin;Jung, Chong-Hun
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.497-504
    • /
    • 2008
  • In a study of the optimum operational condition for a melting decontamination, the effects of the basicity, slag type and slag composition on the distribution of depleted uranium were investigated for radioactively contaminated metallic wastes of iron-based metals such as stainless steel (SUS 304L) in a direct current graphite arc furnace. Most of the depleted uranium was easily moved into the slag from the radioactive metal waste. The partitioning ratio of the depleted uranium was influenced by the amount of added slag former and the slag basicity. The composition of the slag former used to capture contaminants such as depleted uranium during the melt decontamination process generally consists of silica ($SiO_2$), calcium oxide (CaO) and aluminum oxide ($Al_2O_3$). Furthermore, calcium fluoride ($CaF_2$), magnesium oxide (MgO), and ferric oxide ($Fe_2O_3$) were added to increase the slag fluidity and oxidative potential. The partitioning ratio of the depleted uranium was increased as the amount of slag former was increased. Up to 97% of the depleted uranium was captured between the ingot phase and the slag phase. The partitioning ratio of the uranium was considerably dependent on the basicity and composition of the slag. The optimum condition for the removal of the depleted uranium was a basicity level of about 1.5. The partitioning ratio of uranium was high, exceeding $5.5{\times}10^3$. The slag formers containing calcium fluoride ($CaF_2$) and a high amount of silica proved to be more effective for a melt decontamination of stainless steel wastes contaminated with depleted uranium.

pH Dependence on the Degradation of Rhodamine B by Fe-ACF/$TiO_2$ Composites and Effect of Different Fe Precursors (Fe-ACF/$TiO_2$ 복합체에 의한 로다민 B 용액의 분해에 있어서 pH 의존성 및 여러 가지 Fe 전구체의 효과)

  • Zhang, Kan;Oh, Won-Chun
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.408-415
    • /
    • 2009
  • Iron-loaded activated carbon fibers (Fe-ACF) supported titanium dioxide ($TiO_2$) photocatalyst (Fe-ACF/$TiO_2$) was synthesized using a sol-gel method. Three different types of Fe-ACF/$TiO_2$ were obtained by treatment with different precursor of Fe, and characterized using BET, SEM, XRD and EDX analysis. The photocatalytic activity of Fe-ACF/$TiO_2$ was investigated by the degradation of Rhodamine B (Rh.B) solution under UV irradiation. From the experimental results, it was revealed that Fe-ACF/$TiO_2$ composites show considerable photocatalytic ability for the removal of Rh.B by comparing non-treated ACF/$TiO_2$ composites. And photo-Fenton reaction with Fe element was incoordinately influenced due to different precursor of Fe. It clearly indicates that Fe-ACF/$TiO_2$ composites prepared using $FeCl_3$ provided the highest photo-Fenton activity, then, which was affected by pH changes on the degradation of Rh.B.

Precipitation Characteristics of Heavy Metal Ions in Coal Mine Drainage (석탄광산배수에 함유된 중금속 이온의 침전 특성)

  • Jo, Young-Do;Ahn, Ji-Whan;Kim, Hyung-Seok
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.2 s.52
    • /
    • pp.125-134
    • /
    • 2007
  • This study has been carried out in order to examine the precipitation characteristics of Fe, Mn and Al ions in coal mine drainage before removing heavy metals by using the froth flotation method. The removal rate of Fe(III), Mn(II) and Al(III) within 1 h accounted for over 99% in pH 5.0, 10.0, and $6.0{\sim}9.0$ respectively, and residual concentrations of which were under $1mgL^{-1}$. When sodium oleate as a collector was added to the solution of Fe, Mn, and Al ions, insoluble salts was not formed by the reaction of heavy metal and sodium oleate. So, we must remove the metals from coal mine drainage by using not the ion flotation method, but the precipitation flotation method